Hemodynamic and respiratory factors that influence the opening of patent foramen ovale in mechanically ventilated patients

被引:2
作者
Vavlitou, A. [1 ]
Minas, G. [2 ]
Zannetos, S. [3 ]
Kyprianou, T. [1 ]
Tsagourias, M. [4 ]
Matamis, D. [4 ]
机构
[1] Nicosias Gen Hosp, Intens Care Unit, Nicosia, Cyprus
[2] Limassols Gen Hosp, Intens Care Unit, Limassol, Cyprus
[3] Open Univ Cyprus, Fac Econ & Management, Healthcare Management Dept, Nicosia, Cyprus
[4] George Papageorgiou Gen Hosp, Intens Care Unit, Thessaloniki, Greece
关键词
Patent foramen ovale; mechanical ventilation; plateau pressure; positive end-expiratory pressure; right ventricle; ACUTE COR-PULMONALE; DISTRESS-SYNDROME; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; PARADOXICAL EMBOLISM; PRESSURE; PREVALENCE; MULTICENTER; PROGNOSIS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patent foramen ovale (PFO) is an anatomic variant that may lead to several pathological conditions, notably right to left shunt, paradoxical embolism, hypoxemia, and cerebral fat embolism. Mechanical positive pressure ventilation may increase the prevalence of PFO opening in Intensive Care Unit (ICU) patients; however, the respiratory and hemodynamic determinants of PFO opening have been poorly investigated. Contrast-enhanced transesophageal echocardiogram (ce-TEE) is considered the gold standard for PFO detection. We prospectively performed a multicenter study using ce-TEE in order to determine the respiratory and hemodynamic factors that may lead to PFO opening. Methods: One hundred and eight consecutive ICU adult patients under mechanical ventilation from three tertiary care hospitals, were included in the study. A standard multiplane ce-TEE was performed, and the dimensions and function of the right and left ventricle were studied. In each patient, the right ventricle (RV) end-diastolic area, RV end-systolic area, left ventricle (LV) end-diastolic area, and LV ejection fraction were measured using the modified Simpson's rule and the four-chamber view. At least three bubble tests were performed to detect PFO opening. Ventilatory parameters such as tidal volume, plateau pressure, static lung compliance, and positive end-expiratory pressure were recorded during the bubble test. Results: Data for 81 men and 27 women were analyzed. PFO was detected in 27 % of the study population. Statistical significance was found between the presence of PFO and plateau pressure (odds ratio 3.421, 95 % CI: 1.2-9.4, p = 0.017). Additionally, the presence of right ventricular dilatation (RV>LV) was strongly associated with PFO opening (odds ratio 3.163, 95 % CI: 1.2-8.075, p = 0.018). Conclusions: In this group of mechanically ventilated, critically ill adult patients, right ventricular dilatation and plateau pressure above 26 mmHg were significantly associated with foramen ovale opening.
引用
收藏
页码:209 / 213
页数:5
相关论文
共 21 条
[1]   Patent foramen ovale: the current state of play [J].
Asrress, Kaleab N. ;
Marciniak, Maciej ;
Marciniak, Anna ;
Rajani, Ronak ;
Clapp, Brian .
HEART, 2015, 101 (23) :1916-1925
[2]   Prevalence and prognosis of cor pulmonale during protective ventilation for acute respiratory distress syndrome [J].
Boissier, Florence ;
Katsahian, Sandrine ;
Razazi, Keyvan ;
Thille, Arnaud W. ;
Roche-Campo, Ferran ;
Leon, Rusel ;
Vivier, Emmanuel ;
Brochard, Laurent ;
Vieillard-Baron, Antoine ;
Brun-Buisson, Christian ;
Dessap, Armand Mekontso .
INTENSIVE CARE MEDICINE, 2013, 39 (10) :1725-1733
[3]   POSITIVE END-EXPIRATORY PRESSURE INCREASES THE RIGHT-TO-LEFT SHUNT IN MECHANICALLY VENTILATED PATIENTS WITH PATENT FORAMEN OVALE [J].
CUJEC, B ;
POLASEK, P ;
MAYERS, I ;
JOHNSON, D .
ANNALS OF INTERNAL MEDICINE, 1993, 119 (09) :887-894
[4]   Prevalence and prognosis of shunting across patent foramen ovale during acute respiratory distress syndrome [J].
Dessap, Armand Mekontso ;
Boissier, Florence ;
Leon, Rusel ;
Carreira, Serge ;
Campo, Ferran Roche ;
Lemaire, Francoise ;
Brochard, Laurent .
CRITICAL CARE MEDICINE, 2010, 38 (09) :1786-1792
[5]   THE INCIDENCE OF PATENT FORAMEN OVALE IN 1,000 CONSECUTIVE PATIENTS - A CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY STUDY [J].
FISHER, DC ;
FISHER, EA ;
BUDD, JH ;
ROSEN, SE ;
GOLDMAN, ME .
CHEST, 1995, 107 (06) :1504-1509
[6]   Right ventricular function in cardiovascular disease, Part II - Pathophysiology, clinical importance, and management of right ventricular failure [J].
Haddad, Francois ;
Doyle, Ramona ;
Murphy, Daniel J. ;
Hunt, Sharon A. .
CIRCULATION, 2008, 117 (13) :1717-1731
[7]   INCIDENCE AND SIZE OF PATENT FORAMEN OVALE DURING THE 1ST 10 DECADES OF LIFE - AN AUTOPSY STUDY OF 965 NORMAL HEARTS [J].
HAGEN, PT ;
SCHOLZ, DG ;
EDWARDS, WD .
MAYO CLINIC PROCEEDINGS, 1984, 59 (01) :17-20
[8]   Is there a safe plateau pressure in ARDS? The right heart only knows [J].
Jardin, Francois ;
Vieillard-Baron, Antoine .
INTENSIVE CARE MEDICINE, 2007, 33 (03) :444-447
[9]   Patent foramen ovale: A review of associated conditions and the impact of physiological size [J].
Kerut, EK ;
Norfleet, WT ;
Plotnick, GD ;
Giles, TD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) :613-623
[10]   End-inspiratory occlusion maneuver during transesophageal echocardiography for patent foramen ovale detection in intensive care unit patients [J].
Koroneos, Apostolos ;
Politis, Panagiotis ;
Malachias, Sotiris ;
Manolis, Antonis S. ;
Vassilakopoulos, Theodoros .
INTENSIVE CARE MEDICINE, 2007, 33 (08) :1458-1462