Development and validation of a multiplex immunoassay for the simultaneous determination of serum antibodies to Bordetella pertussis, diphtheria and tetanus

被引:169
作者
van Gageldonk, Pieter G. M. [1 ]
van Schaijk, Frank G. [1 ]
van der Klis, Fiona R. [1 ]
Berbers, Guy A. M. [1 ]
机构
[1] Natl Inst Publ Hlth & Environm, Lab Infect Dis & Perinatal Screening, NL-3720 BA Bilthoven, Netherlands
关键词
multiplex immunoassay; ELISA; Bordetella pertussis; diphtheria; tetanus; Luminex;
D O I
10.1016/j.jim.2008.02.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To increase testing of vaccine induced humoral immunity in immune surveillance studies and vaccine trials, a rapid and simple microsphere-based multiplex assay (pentaplex) was developed for the quantitation of IgG serum antibodies directed against the Bordetella pertussis antigens: Pertussis Toxin (Ptx), Filamentous hemagglutinin (FHA), Pertactin (Prn) and to Diphtheria toxin and Tetanus toxin. All individual antigens were covalently linked to carboxylated microspheres. The method was validated with different serum panels (n = 60-78 samples). With the Multiplex Immunoassay (MIA) no evidence for bead interference between monoplex and pentaplex was found. The specificity of the method was shown by a heterologous inhibition of <16% and homologous inhibition of >92%. The pentaplex MIA appeared sensitive with lower limits of quantitation (LLOQ) well below those for ELISA (enzyme-linked immuno-sorbant assay). Assay reproducibility was high with intra-assay variability less than 10% and inter-assay variability below 14%. The reproducibility of the bead conjugation was good and beads could be stored up to at least 6 months without quality reduction. Importantly, the correlation of the pentaplex MIA with the individual ELISAs was excellent, R>0.98 for the Pertussis antigens and R=0.95 for Diphtheria and R=0.98 for Tetanus. Serum IgG antibodies to B. pertussis, Diphtheria and Tetanus can be measured easily, specific and reproducible using the pentaplex MIA. The pentaplex MIA shares features of the ELISA with the additional advantages of high sample throughput and small sample volumes and antigen required. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 89
页数:11
相关论文
共 21 条
[1]  
Berbers GAM, 1999, 105000001 RIVM
[2]   Method for simultaneous measurement of antibodies to 23 pneumococcal capsular polysaccharides [J].
Biagini, RE ;
Schlottmann, SA ;
Sammons, DL ;
Smith, JP ;
Snawder, JC ;
Striley, CAF ;
MacKenzie, BA ;
Weissman, DN .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (05) :744-750
[3]   Specificity and sensitivity of high levels of immunoglobulin G antibodies against pertussis toxin in a single serum sample for diagnosis of infection with Bordetella pertussis [J].
de Melker, HE ;
Versteegh, FGA ;
Conyn-van Spaendonck, MAE ;
Elvers, LH ;
Berbers, GAM ;
van der Zee, A ;
Schellekens, JFP .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (02) :800-806
[4]   Optimization and validation of a multiplexed Luminex assay to quantify antibodies to neutralizing epitopes on human papillomaviruses 6, 11, 16, and 18 [J].
Dias, D ;
Van Doren, J ;
Schlottmann, S ;
Kelly, S ;
Puchalski, D ;
Ruiz, W ;
Boerckel, P ;
Kessler, J ;
Antonello, JM ;
Green, T ;
Brown, M ;
Smith, J ;
Chirmule, N ;
Barr, E ;
Jansen, KU ;
Esser, MT .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2005, 12 (08) :959-969
[5]  
EDWARDS KM, 1995, PEDIATRICS, V96, P548
[6]  
*EMEA, 1995, NOT GUID VAL AN PROC
[7]   European Sero-Epidemiology Network:: standardisation of the assay results for pertussis [J].
Giammanco, A ;
Chiarini, A ;
Maple, PAC ;
Andrews, N ;
Pebody, R ;
Gay, N ;
Ölander, RM ;
Fivet-Groyne, R ;
Baron, S ;
Tischer, A ;
Swidsinski, S ;
Schellekens, J ;
Reizenstein, E .
VACCINE, 2003, 22 (01) :112-120
[8]   COMBINED ESTIMATION OF TETANUS AND DIPHTHERIA ANTITOXIN IN HUMAN-SERA BY THE INVITRO TOXIN-BINDING INHIBITION (TOBI) TEST [J].
HENDRIKSEN, CFM ;
VANDERGUN, JW ;
KREEFTENBERG, JG .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1989, 17 (02) :191-200
[9]   The Bordetella pertussis virulence factor P.69 pertactin retains its immunological properties after overproduction in Escherichia coli [J].
Hijnen, M ;
van Gageldonk, PGM ;
Berbers, GAM ;
van Woerkom, T ;
Mooi, FR .
PROTEIN EXPRESSION AND PURIFICATION, 2005, 41 (01) :106-112
[10]   Development and evaluation of a tetraplex flow cytometric assay for quantitation of serum antibodies to Neisseria meningitidis serogroups A, C, Y, and W-135 [J].
Lal, G ;
Balmer, P ;
Joseph, H ;
Dawson, M ;
Borrow, R .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2004, 11 (02) :272-279