Barium Hydrogen Phosphate Modified Carbon Paste Electrode for the Simultaneous Determination of Cadmium and Lead by Differential Pulse Anodic Stripping Voltammetry

被引:15
作者
Sheela, T. [1 ]
Basavanna, S. [1 ]
Viswanatha, R. [1 ]
Kalachar, H. C. B. [1 ]
Naik, Y. Arthoba [1 ]
机构
[1] Kuvempu Univ, Sch Chem Sci, Dept Chem, Shankaraghatta 577451, Karnataka, India
关键词
Barium hydrogen phosphate; Cadmium; Carbon paste; Lead; Nafion; Stripping analysis; BISMUTH-FILM ELECTRODES; TRACE LEAD(II); HEAVY-METALS; COMPLEXATION; FABRICATION; PB(II); SILICA; PB; CD; CU;
D O I
10.1002/elan.201000679
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The barium hydrogen phosphate modified carbon paste electrode (BHP-CPE) was prepared as an electrochemical sensor. Its propensity towards the simultaneous determination of Cd(II) and Pb(II) has been demonstrated with differential pulse anodic stripping voltammetry (DPASV) in the potential window between -1.2 V to -0.4 V. Important operational parameters such as pH of the solution, deposition potential and deposition time have been optimized. Under the optimized conditions, calibration curves were linear in the concentration range 1 x 10(-8) to 8 x 10(-8) M on BHP-CPE and 1 x 10(-8) to 5 x 10(-8) M on Nafion-BHP-CPE. Experiments disclosed that BHP-CPE and Nafion-BHP-CPE exhibit good performance for the simultaneous determination of Cd(II) and Pb(II).
引用
收藏
页码:1150 / 1157
页数:8
相关论文
共 28 条
[11]   Bismuth nano-powder electrode for trace analysis of heavy metals using anodic stripping voltammetry [J].
Lee, Gyoung-Ja ;
Lee, Hi-Min ;
Rhee, Chang-Kyu .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (10) :2514-2518
[12]   Addressing lead toxicity: Complexation of lead(II) with thiopyrone and hydroxypyridinethione O,S mixed chelators [J].
Lewis, JA ;
Cohen, SM .
INORGANIC CHEMISTRY, 2004, 43 (21) :6534-6536
[13]   Nafion-graphene nanocomposite film as enhanced sensing platform for ultrasensitive determination of cadmium [J].
Li, Jing ;
Guo, Shaojum ;
Zhai, Yueming ;
Wang, Erkang .
ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (05) :1085-1088
[14]   A Study of Nafion-Coated Bismuth-Film Electrode for the Determination of Zinc, Lead, and Cadmium in Blood Samples [J].
Liu, Benzhi ;
Lu, Liyuan ;
Wang, Min ;
Zi, Yanqin .
ELECTROANALYSIS, 2008, 20 (21) :2363-2369
[15]   Fabrication and Characterization of Carbon Nanotube-Hydroxyapatite Nanocomposite: Application to Anodic Stripping Voltammetric Determination of Cadmium [J].
Pan, Dawei ;
Wang, Yuane ;
Chen, Zhaopeng ;
Yin, Tanji ;
Qin, Wei .
ELECTROANALYSIS, 2009, 21 (08) :944-952
[16]   Solubility and crystillization of BaHPO4 crystals [J].
Pan, DY ;
Yuan, DR ;
Sun, HQ ;
Guo, SY ;
Wang, XQ ;
Duan, XL ;
Luan, CN ;
Li, ZF .
CRYSTAL RESEARCH AND TECHNOLOGY, 2006, 41 (03) :236-238
[17]   Exfoliated graphite oxide modified electrode for the selective determination of picomolar concentration of lead [J].
Ramesha, G. K. ;
Sampath, S. .
ELECTROANALYSIS, 2007, 19 (23) :2472-2478
[18]   Bismuth Film Electrode in Metal Complexation Studies: Stripping Analysis of the Pb(II)-, Cd(II)-, and Zn(II)-Binding with Phthalate [J].
Serrano, Nuria ;
Martin, Nuria ;
Manuel Diaz-Cruz, Jose ;
Arino, Cristina ;
Esteban, Miquel .
ELECTROANALYSIS, 2009, 21 (3-5) :431-438
[19]   Determination of nanomolar concentrations of Pb(II) using carbon paste electrode modified with zirconium phosphated amorphous silica [J].
Shams, E ;
Alibeygi, F ;
Torabi, R .
ELECTROANALYSIS, 2006, 18 (08) :773-778
[20]   Simultaneous determination of Cd, Pb, and Cu metal trace concentrations in water certified samples and soil extracts by means of Hg-electroplated-Ir microelectrode array based sensors [J].
Silva, PRM ;
El Khakani, MA ;
Chaker, M ;
Dufresne, A ;
Courchesne, F .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :250-257