共 28 条
Barium Hydrogen Phosphate Modified Carbon Paste Electrode for the Simultaneous Determination of Cadmium and Lead by Differential Pulse Anodic Stripping Voltammetry
被引:15
作者:
Sheela, T.
[1
]
Basavanna, S.
[1
]
Viswanatha, R.
[1
]
Kalachar, H. C. B.
[1
]
Naik, Y. Arthoba
[1
]
机构:
[1] Kuvempu Univ, Sch Chem Sci, Dept Chem, Shankaraghatta 577451, Karnataka, India
关键词:
Barium hydrogen phosphate;
Cadmium;
Carbon paste;
Lead;
Nafion;
Stripping analysis;
BISMUTH-FILM ELECTRODES;
TRACE LEAD(II);
HEAVY-METALS;
COMPLEXATION;
FABRICATION;
PB(II);
SILICA;
PB;
CD;
CU;
D O I:
10.1002/elan.201000679
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The barium hydrogen phosphate modified carbon paste electrode (BHP-CPE) was prepared as an electrochemical sensor. Its propensity towards the simultaneous determination of Cd(II) and Pb(II) has been demonstrated with differential pulse anodic stripping voltammetry (DPASV) in the potential window between -1.2 V to -0.4 V. Important operational parameters such as pH of the solution, deposition potential and deposition time have been optimized. Under the optimized conditions, calibration curves were linear in the concentration range 1 x 10(-8) to 8 x 10(-8) M on BHP-CPE and 1 x 10(-8) to 5 x 10(-8) M on Nafion-BHP-CPE. Experiments disclosed that BHP-CPE and Nafion-BHP-CPE exhibit good performance for the simultaneous determination of Cd(II) and Pb(II).
引用
收藏
页码:1150 / 1157
页数:8
相关论文