The effects of multilayered Ti/TiN or single-layered TiN films deposited by pulse-biased arc ion plating (PBAIP) on the corrosion behavior of NiTi orthodontic brackets in artificial saliva are investigated. The multilayered Ti/TiN coating is found to exhibit a greater free corrosion potential, much lower passive current density, and no breakdown up to 1.5 V. Moreover, electrochemical impedance spectroscopy (EIS) results indicate that the multilayered Ti/TiN coating has a larger impedance and lower porosity which is believed to be responsible for the exceedingly low metal ion release rate during 720 h exposure in the test solution. Visual inspection of the surfaces reveals different corrosion processes for the TiN and multilayered Ti/TiN coatings. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3783 / 3796
页数:14
相关论文
共 28 条
[1]   Localized corrosion mechanisms of the multilayered coatings related to growth defects [J].
Alm, SH ;
Lee, JH ;
Kim, JG ;
Han, JG .
SURFACE & COATINGS TECHNOLOGY, 2004, 177 :638-644
[2]  
[Anonymous], WIRE J INT
[3]   In vitro corrosion testing of PVD coatings applied to a surgical grade Co-Cr-Mo alloy [J].
Bolton, J ;
Hu, X .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (06) :567-574
[4]   Porosity evaluation of protective coatings onto steel, through electrochemical techniques [J].
Creus, J ;
Mazille, H ;
Idrissi, H .
SURFACE & COATINGS TECHNOLOGY, 2000, 130 (2-3) :224-232
[5]   Macro-particle reduction mechanism in biased arc ion plating of TiN [J].
Huang, MD ;
Lin, GQ ;
Zhao, YH ;
Sun, C ;
Wen, LS ;
Dong, CA .
SURFACE & COATINGS TECHNOLOGY, 2003, 176 (01) :109-114
[6]  
Jia WY, 1999, J BIOMED MATER RES, V48, P488, DOI 10.1002/(SICI)1097-4636(1999)48:4<488::AID-JBM14>3.0.CO
[7]  
2-D
[8]  
JORMA R, 1999, BIOCOMPABIBILITY EVA, V36
[9]   The anticorrosion ability of titanium nitride (TiN) plating on an orthodontic metal bracket and its biocompatibility [J].
Kao, CT ;
Ding, SJ ;
Chen, YC ;
Huang, TH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (06) :786-792
[10]   NITINOL URETHRAL STENTS - LONG-TERM RESULTS IN DOGS [J].
LATAL, D ;
MRAZ, J ;
ZERHAU, P ;
SUSANI, M ;
MARBERGER, M .
UROLOGICAL RESEARCH, 1994, 22 (05) :295-300