A Fast Neutron Detector Using 10B-Lined Ionization Chamber for Mixed Field Dosimetry

被引:0
|
作者
Zhang, Zixia [1 ]
Wei, Zhiyong [2 ]
Fang, Meihua [2 ]
Zhu, Li [2 ]
Chen, Guoyun [3 ]
Qiang, Peng [2 ]
Ni, Qin [2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mat Sci & Technol, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Astronaut, Nanjing, Jiangsu, Peoples R China
[3] Nanchang Univ, Sch Sci, Nanchang, Peoples R China
来源
2015 15TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS (RADECS) | 2015年
关键词
boron; fast neutron; n/gamma mixed field; multi-cylinder HDPE; ionization chamber;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We designed a new fast neutron Bonner multi-cylinder neutron detector using boroned-lined ionization chamber, wrapped in a set of 5 high density polyethylene cylinders. The ionization chamber consists of the cavity chamber twins. The response function of Bonner multi-cylinder neutron detector was simulated by Geant4 code. The sensitivity of detector reaches a level of 8.702x10(-15)A/(cm(-2).s(-1)) under the experiments based on the Am-241-Be neutron source.
引用
收藏
页数:4
相关论文
共 45 条
  • [1] Design and response function of fast neutron detector using boron-lined ionization chamber
    Zhang, Zi-Xia
    Wei, Zhi-Yong
    Fang, Mei-Hua
    Zhu, Li
    Chen, Guo-Yun
    Shi, Miao
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 (07): : 1274 - 1280
  • [2] Performances of a boron-lined ionization chamber used in neutron/γ-ray mixed field of reactors
    Chen Guo-Yun
    Xin Yong
    Huang Fu-Cheng
    Wei Zhi-Yong
    Lei Sheng-Jie
    Huang San-Bo
    Zhu Li
    Zhao Jing-Wu
    Ma Jia-Yi
    ACTA PHYSICA SINICA, 2012, 61 (08)
  • [3] Ionization Loss Simulation in Gaps of Fast Neutron Detector Based on 10B Layer and Gaseous Chamber
    Potashev, S. I.
    PHYSICS OF ATOMIC NUCLEI, 2023, 86 (05) : 850 - 853
  • [4] Experimental Validation of Small-field Dosimetry in Radiotherapy Using Ionization Chamber and Edge Detector
    Aghayan S.A.
    Nateghi N.
    Layegh M.
    Aghayan, Seyed Ali (ali_aghayan@ymail.com), 1600, Mashhad University of Medical Sciences (18): : 149 - 153
  • [5] Development of boron-lined ionization chamber used in n/γ mixed field
    Wei, Z.-Y. (wzy_msc@nuaa.edu.cn), 1624, Atomic Energy Press (47):
  • [6] An alternative method of neutron-gamma mixed-field dosimetry by using paired ionization chambers
    Nohtomi, A.
    Sugiura, N.
    Itoh, T.
    Sakae, T.
    Terunuma, T.
    Fujibuchi, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 614 (01): : 159 - 161
  • [7] Study of the Use of an ionization chamber-based Transmission Detector in Small-Field Dosimetry
    Tegethoff, M.
    Ibisi, S.
    Waletzko, O.
    Rohn, R.
    Block, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S182 - S182
  • [8] Set-up and calibration of a triple ionization chamber system for dosimetry in mixed neutron/photon fields
    Becker, J.
    Brunckhorst, E.
    Roca, A.
    Stecher-Rasmussen, F.
    Moss, R.
    Boettger, R.
    Schmidt, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13): : 3715 - 3727
  • [9] OPTIMIZATION OF ELECTRET IONIZATION-CHAMBER FOR DOSIMETRY IN MIXED NEUTRON-GAMMA RADIATION-FIELDS
    DORSCHEL, B
    PRETZSCH, G
    RADIATION PROTECTION DOSIMETRY, 1984, 9 (01) : 43 - 47
  • [10] Concept of a fast neutron detector based on 10B-RPCs
    Morozov, A.
    Margato, L. M. S.
    Blanco, A.
    Galaviz, D.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (02)