Assessment of a portable device for the quantitative measurement of ankle joint stiffness in spastic individuals

被引:22
作者
Lorentzen, Jakob [2 ,3 ]
Grey, Michael J. [4 ]
Geertsen, Svend S. [4 ]
Biering-Sorensen, Fin [5 ]
Brunton, Kelly [6 ]
Gorassini, Monica [6 ]
Nielsen, Jens Bo [1 ,4 ]
机构
[1] Univ Copenhagen, Dept Phys Exercise & Sport Sci, Panum Inst, DK-2200 Copenhagen N, Denmark
[2] Hvidovre Univ Hosp, Dept Physiotherapy, DK-2950 Hvidovre, Denmark
[3] Copenhagen Univ Hosp, Dept Neurorehabil, TBI Unit, Glostrup, Denmark
[4] Univ Copenhagen, Dept Neurosci & Pharmacol, DK-2200 Copenhagen N, Denmark
[5] Univ Copenhagen, Clin Spinal Cord Injury, Rigshosp, Fac Hlth Sci, DK-2100 Copenhagen O, Denmark
[6] Univ Alberta, Dept Biomed Engn, Edmonton, AB, Canada
关键词
Spasticity; Spasticity evaluation; Stiffness; Spinal cord injury; Multiple sclerosis; MULTIPLE-SCLEROSIS PATIENTS; TONE MEASUREMENT DEVICE; SPINAL-CORD-INJURY; MUSCLE TONE; HAND-HELD; REFLEX; STRETCH; RIGIDITY; PATHOPHYSIOLOGY; COMPONENTS;
D O I
10.1016/j.clinph.2011.11.001
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Spasticity is a common complication with neurological diseases and CNS lesions. Instrumented systems to evaluate spasticity often cannot provide an immediate result, thus limiting their clinical usefulness. In this study we investigated the accuracy and reliability of the portable Neurokinetics RA1 Ridgidity Analyzer to measure stiffness of the ankle joint in 46 controls, 14 spinal cord injured (SCI) and 23 multiple sclerosis (MS) participants. Methods: Ankle stiffness measures were made twice by two raters, at speeds above and below the expected stretch reflex threshold. Ankle torque was measured with the portable device and a stationary torque motor. Inter- and intra-rater reliability was assessed with the intra-class correlation coefficient (ICC). Results: Stiffness measures with the portable and stationary devices were significantly correlated for controls and MS participants (p < 0.01). Intra-rater reliability for the portable device ranged from 0.60-0.89 (SCI) and 0.63-0.67 (control) and inter-rater reliability ranged from 0.70-0.73 (SCI) and 0.61-0.77 (control). Ankle stiffness measures in SCI and MS participants were significantly larger than in controls for both slow (p < 0.05) and fast movements (p < 0.01), with stiffness being larger for fast compared to slow movements in SCI and MS participants (p < 0.05), but not in controls (p = 0.5). Conclusion: The portable device correlated well with measures obtained by a torque motor in both controls and MS participants, showed high intra- and inter-rater reliability for the SCI participants, and could easily distinguish between stiff and control ankle joints. However, the device, in its current form, maybe less accurate during rapid movements when inertia contributes to stiffness and the shape of the air-filled pads did not provide a good interface with the foot. Significance: This study demonstrates that a portable device can potentially be a useful diagnostic tool to obtain reliable information of stiffness for the ankle joint. (C) 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1371 / 1382
页数:12
相关论文
共 37 条
[1]  
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[2]   Spasticity-assessment: a review [J].
Biering-Sorensen, F. ;
Nielsen, J. B. ;
Klinge, K. .
SPINAL CORD, 2006, 44 (12) :708-722
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[5]   USE OF A HAND-HELD DYNAMOMETER AND A KIN-COM(R) DYNAMOMETER FOR EVALUATING SPASTIC HYPERTONIA IN CHILDREN - A RELIABILITY STUDY [J].
BOITEAU, M ;
MALOUIN, F ;
RICHARDS, CL .
PHYSICAL THERAPY, 1995, 75 (09) :796-802
[6]   The use of a portable muscle tone measurement device to measure the effects of botulinum toxin type a on elbow flexor spasticity [J].
Chen, JJJ ;
Wu, YN ;
Huang, SC ;
Lee, HM ;
Wang, YL .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (08) :1655-1660
[7]   NORMAL AND IMPAIRED REGULATION OF MUSCLE-STIFFNESS IN GAIT - A NEW HYPOTHESIS ABOUT MUSCLE HYPERTONIA [J].
DIETZ, V ;
BERGER, W .
EXPERIMENTAL NEUROLOGY, 1983, 79 (03) :680-687
[8]   REFLEX ACTIVITY AND MUSCLE TONE DURING ELBOW MOVEMENTS IN PATIENTS WITH SPASTIC PARESIS [J].
DIETZ, V ;
TRIPPEL, M ;
BERGER, W .
ANNALS OF NEUROLOGY, 1991, 30 (06) :767-779
[9]   ELECTRO-PHYSIOLOGICAL STUDIES OF GAIT IN SPASTICITY AND RIGIDITY - EVIDENCE THAT ALTERED MECHANICAL-PROPERTIES OF MUSCLE CONTRIBUTE TO HYPERTONIA [J].
DIETZ, V ;
QUINTERN, J ;
BERGER, W .
BRAIN, 1981, 104 (SEP) :431-449
[10]   Spastic movement disorder: impaired reflex function and altered muscle mechanics [J].
Dietz, Volker ;
Sinkjaer, Thomas .
LANCET NEUROLOGY, 2007, 6 (08) :725-733