Capnographic monitoring for carbon dioxide insufflation during endoscopic mucosal dissection: comparison of transcutaneous and end-tidal capnometers

被引:9
作者
Kusunoki, Ryusaku [2 ]
Amano, Yuji [1 ]
Yuki, Takafumi [1 ]
Oka, Akihiko [2 ]
Okada, Mayumi [2 ]
Tada, Yasumasa [2 ]
Uno, Goichi [1 ]
Moriyama, Ichiro [3 ]
Ishimura, Norihisa [2 ]
Ishihara, Shunji [2 ]
Kinoshita, Yoshikazu [2 ]
机构
[1] Shimane Univ Hosp, Div Endoscopy, Izumo, Shimane 6938501, Japan
[2] Shimane Univ, Fac Med, Dept Internal Med 2, Izumo, Shimane, Japan
[3] Shimane Univ Hosp, Div Canc Ctr, Izumo, Shimane 6938501, Japan
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2012年 / 26卷 / 02期
关键词
Capnography; ESD; EtCO(2); PtCO(2); SPONTANEOUSLY BREATHING PATIENTS; DOUBLE-BLIND TRIAL; SUBMUCOSAL DISSECTION; CLINICAL-EVALUATION; PULSE OXIMETRY; COLONOSCOPY; EFFICACY; PATIENT; CO2; ANESTHESIA;
D O I
10.1007/s00464-011-1908-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
The use of carbon dioxide (CO(2)) insufflation during endoscopic procedures is effective in reducing patient discomfort caused by bloating. However, transcutaneous arterial CO(2) (PtCO(2)) monitoring usually is required for safety during long endoscopic procedures. To evaluate a new capnometer for monitoring end-tidal carbon dioxide (EtCO(2)) concentrations and to compare PtCO(2) with EtCO(2) measured in the same patient, a prospective comparative study of EtCO(2) and PtCO(2) values measured simultaneously was designed. The study enrolled 20 consecutive patients (18 men and two women; mean age, 70.1 years) with upper gastrointestinal neoplasms scheduled for endoscopic submucosal dissection (ESD) using conscious sedation with CO(2) insufflation, and EtCO(2) and PtCO(2) were simultaneously measured by each capnometer. Patient status was evaluated before ESD by the American Society of Anesthesiologists (ASA) physical status classification system, and eight patients were judged as class 1, nine patients as class 2, and three patients as class 3. The exclusion criteria ruled out patients with chronic obstructive pulmonary disease or ASA class 4 or 5 physical status. The correlation between EtCO(2) and PtCO(2) values and the availability of EtCO(2) capnography were investigated. The mean EtCO(2) value during ESD was 34.7 +/- A 4.5 mmHg, and the mean PtCO(2) value was 51.6 +/- A 2.4 mmHg. There was a statistically significant correlation between EtCO(2) and PtCO(2) (r = 0.331; P = 0.002). Hypoxic events (< 90% oxygen saturation [SpO(2)]) caused by decreased respiratory rate occurred for 12 patients. In 10 (83%) of 12 events, a significant reduction in EtCO(2) was seen before the decrease in SpO(2). The EtCO(2) values correlated with the PtCO(2) values, and the respiratory monitoring methods allowed earlier detection of hypoxia during ESD with conscious sedation than transcutaneous monitoring. The EtCO(2) capnometer was considered to be available for the ESD procedure with the patient under conscious sedation using CO(2) insufflation.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 50 条
  • [31] Continuous end-tidal carbon dioxide monitoring in pediatric intensive care units
    Langhan, Melissa
    JOURNAL OF CRITICAL CARE, 2009, 24 (02) : 227 - 230
  • [32] Noninvasive Capnometry for End-tidal Carbon Dioxide Monitoring via Nasal Cannula in Nonintubated Neonates
    Tai, Chih-Che
    Lu, Frank Leigh
    Chen, Pau-Chung
    Jeng, Suh-Fang
    Chou, Hung-Chieh
    Chen, Chien-Yi
    Tsao, Po-Nien
    Hsieh, Wu-Shiun
    PEDIATRICS AND NEONATOLOGY, 2010, 51 (06) : 330 - 335
  • [33] Safety of Carbon Dioxide Insufflation during Endoscopic Submucosal Dissection for Esophageal Squamous Cell Carcinoma
    Takada, Jun
    Araki, Hiroshi
    Mizutani, Taku
    Ozawa, Noritaka
    Sugiyama, Tomohiko
    Kubota, Masaya
    Ibuka, Takashi
    Shimizu, Masahito
    DIGESTIVE DISEASES, 2019, 37 (02) : 93 - 99
  • [34] The usefulness of end-tidal carbon dioxide monitoring during apnea test in brain-dead patients
    Kim, Ha Yeon
    Kim, Gaab-Soo
    Shin, Young Hee
    Cha, So Ra
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 67 (03) : 186 - 192
  • [35] ARE PULSE OXIMETRY AND END-TIDAL CARBON-DIOXIDE TENSION MONITORING RELIABLE DURING LAPAROSCOPIC SURGERY
    NYARWAYA, JB
    MAZOIT, JX
    SAMII, K
    ANAESTHESIA, 1994, 49 (09) : 775 - 778
  • [36] End-tidal carbon dioxide monitoring improves patient safety during propofol-based sedation for breast lumpectomy A randomised controlled trial
    Li, Mengzhu
    Liu, Zhiqiang
    Lin, Fuqing
    Wang, Huiying
    Niu, Xiaozhen
    Ge, Xun
    Fu, Shukun
    Fang, Lin
    Li, Cheng
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2018, 35 (11) : 848 - 855
  • [37] Simultaneous measurements of end-tidal and transcutaneous carbon dioxide pressure in ventilated preterm and term newborn infants
    Arsowa, S
    Schmalisch, G
    Wauer, RR
    KLINISCHE PADIATRIE, 1997, 209 (02): : 47 - 53
  • [38] Detection of hypoventilation during deep sedation in patients undergoing ambulatory gynaecological hysteroscopy: a comparison between transcutaneous and nasal end-tidal carbon dioxide measurements
    De Oliveira, G. S., Jr.
    Ahmad, S.
    Fitzgerald, P. C.
    McCarthy, R. J.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 104 (06) : 774 - 778
  • [39] Uses and pitfalls of measurement of end-tidal carbon dioxide during cardiac arrest
    Nicholson, Tonia C.
    Paiva, Edison F.
    CURRENT OPINION IN CRITICAL CARE, 2020, 26 (06) : 612 - 616
  • [40] COMPARISON OF END-TIDAL AND ARTERIAL CARBON-DIOXIDE MEASUREMENTS DURING ANESTHESIA WITH THE LARYNGEAL MASK AIRWAY
    HICKS, IR
    SONI, NC
    SHEPHARD, JN
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (05) : 734 - 735