Metal-ceramic bond strength of Co-Cr alloy fabricated by selective laser melting

被引:81
作者
Xiang, Nan [1 ]
Xin, Xian-Zhen [1 ]
Chen, Jie [1 ]
Wei, Bin [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Peoples Hosp 9,Shanghai Key Lab Stomat, Stomatol Special Consultat Clin,Dept Prosthodont, Shanghai 200011, Peoples R China
关键词
Co-Cr; Selective laser melting (Slm); Metal-ceramic; Bonding; Sem; Bending test; PORCELAIN ADHERENCE; FRACTURE; GOLD;
D O I
10.1016/j.jdent.2012.02.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study was to evaluated the metal-ceramic bond strength of a Co-Cr dental alloy prepared using a selective laser melting (SLM) technique. Methods: Two groups comprised of twenty Co-Cr metal bars each were prepared using either a SLM or traditional lost-wax casting method. Ten bars from each group were moulded into standard ISO 9693:1999 dimensions of 25 mm x 3 mm x 0.5 mm with 1.1 mm of porcelain fused onto an 8 mm x 3 mm rectangular area in the centre of each bar. Metal-ceramic bonding was assessed using a three-point bending test. Fracture mode analysis and area fraction of adherence porcelain (AFAP) were determined by measuring Si content of specimens by SEM/EDS. Results: Student's t-test within the groups demonstrated no significant difference for the mean bond strength between the SLM and traditional cast sample groups. While SEM/EDS analysis indicated a mixed fracture mode on the debonding interface of both the SLM and the cast groups, the SLM group showed significantly more porcelain adherence than the control group (p < 0.05). Conclusions: The SLM metal-ceramic system exhibited a bonding strength that exceeds the requirement of ISO 9691: 1999(E) and it even showed a better behaviour in porcelain adherence test comparable to traditional cast methods. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:453 / 457
页数:5
相关论文
共 20 条
[11]   Longevity of fixed partial dentures [J].
Libby, G ;
Arcuri, MR ;
LaVelle, WE ;
Hebl, L .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (02) :127-131
[12]   FRACTURE LOAD OF TITANIUM CROWNS COATED WITH GOLD OR TITANIUM NITRIDE AND BONDED TO LOW-FUSING PORCELAIN [J].
Lim, Hyn-Pil ;
Msd, Ji-Hye Kim Dds ;
Lee, Kwang-Min ;
Park, Sang-Won .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (03) :164-170
[13]   Influence of Surface Treatment on the Shear Bond Strength of Ceramics Fused to Cobalt-Chromium [J].
Lombardo, Geraldo H. L. ;
Nishioka, Renato S. ;
Souza, Rodrigo O. A. ;
Michida, Silvia M. A. ;
Kojima, Alberto N. ;
Mesquita, Alfredo M. M. ;
Buso, Leonardo .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (02) :103-111
[14]   High density selective laser melting of Waspaloy® [J].
Mumtaz, Kamran Aamir ;
Erasenthiran, Poonjolai ;
Hopkinson, Neil .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2008, 195 (1-3) :77-87
[15]   Fracture reasons in ceramic-fused-to-metal restorations [J].
Özcan, M .
JOURNAL OF ORAL REHABILITATION, 2003, 30 (03) :265-269
[16]   Porcelain adherence vs force to failure for palladium-gallium alloys:: A critique of metal-ceramic bond testing [J].
Papazoglou, E ;
Brantley, WA .
DENTAL MATERIALS, 1998, 14 (02) :112-119
[17]   AN X-RAY SPECTROMETRIC TECHNIQUE FOR MEASURING PORCELAIN-METAL ADHERENCE [J].
RINGLE, RD ;
MACKERT, JR ;
FAIRHURST, CW .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (08) :933-936
[18]  
Strub J R, 1988, Quintessence Int, V19, P215
[19]   A study of the micro structural evolution during selective laser melting of Ti-6Al-4V [J].
Thijs, Lore ;
Verhaeghe, Frederik ;
Craeghs, Tom ;
Van Humbeeck, Jan ;
Kruth, Jean-Pierre .
ACTA MATERIALIA, 2010, 58 (09) :3303-3312
[20]   Bond strength and interfacial characterization of eight low fusing porcelains to cp Ti [J].
Zinelis, S. ;
Barmpagadaki, X. ;
Vergos, V. ;
Chakmakchi, M. ;
Eliades, G. .
DENTAL MATERIALS, 2010, 26 (03) :264-273