Mathematical modeling and cascade design of hollow fiber membrane contactor for CO2 absorption by monoethanolamine

被引:60
作者
Boributh, Somnuk [1 ]
Rongwong, Wichitpan [1 ]
Assabumrungrat, Suttichai [2 ]
Laosiripojana, Navadol [3 ]
Jiraratananon, Ratana [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Dept Chem Engn, Bangkok 10140, Thailand
[2] Chulalongkorn Univ, Dept Chem Engn, Fac Engn, Bangkok 10330, Thailand
[3] King Mongkuts Univ Technol Thonburi, Joint Grad Sch Energy & Environm, Bangkok 10140, Thailand
关键词
Carbon dioxide; Cascade design; Membrane contactor; Membrane wetting; MASS-TRANSFER; CARBON-DIOXIDE; GAS; RESISTANCE; REMOVAL;
D O I
10.1016/j.memsci.2012.01.048
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The absorption of CO2 from the gas mixture (CO2-CH4) by polyvinylidenefluoride (PVDF) hollow fiber membrane contactor using monoethanolamine (MEA) as the absorbent was performed. The mathematical model has been developed to predict the absorption performance. The model is validated with the experimental results for estimating the wetting ratio (x*) as the function of liquid velocity and MEA concentration. The suitable hollow fiber membrane module with effective fiber length of 50 cm is selected for the design of multistage membrane contactors. The absorption flux of multistage membrane contactor is simulated based on the value of x* obtained from the experiments. The three-stage cascade design is selected to compare the system performance with different gas and liquid flow patterns. The results of the simulation show that the individual gas flow (G-ID) gives higher performance compared to the gas flow in series (G-IS) for all operating conditions studied. The three different flow patterns of liquid including (i) liquid flow in series (L-IS), (ii) liquid flow in series with splitting (L-ISS) and (iii) liquid flow in series with recycle (L-ISR) are compared. At low MEA concentration (0.25 M), the L-ISR can improve the system performance at low liquid velocities, while L-ISS shows the highest performance at high liquid velocities. For the system with high MEA concentration (1.0 M), L-ISR can improve the performance at low to moderate liquid velocities, whereas L-ISS does not improve the system performance at any liquid velocity. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 189
页数:15
相关论文
共 25 条
[1]   Mass transfer study and modeling of gas-liquid membrane contacting process by multistage cascade model for CO2 absorption [J].
Atchariyawut, Supakorn ;
Jiraratananon, Ratana ;
Wang, Rong .
SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 63 (01) :15-22
[2]   Separation of CO2 from CH4 by using gas-liquid membrane contacting process [J].
Atchariyawut, Supakorn ;
Jiraratananon, Ratana ;
Wang, Rong .
JOURNAL OF MEMBRANE SCIENCE, 2007, 304 (1-2) :163-172
[3]   A modeling study on the effects of membrane characteristics and operating parameters on physical absorption of CO2 by hollow fiber membrane contactor [J].
Boributh, Somnuk ;
Assabumrungrat, Suttichai ;
Laosiripojana, Navadol ;
Jiraratananon, Ratana .
JOURNAL OF MEMBRANE SCIENCE, 2011, 380 (1-2) :21-33
[4]   Effect of membrane module arrangement of gas-liquid membrane contacting process on CO2 absorption performance: A modeling study [J].
Boributh, Somnuk ;
Assabumrungrat, Suttichai ;
Laosiripojana, Navadol ;
Jiraratananon, Ratana .
JOURNAL OF MEMBRANE SCIENCE, 2011, 372 (1-2) :75-86
[5]   CO2 removal from a gas stream by membrane contactor [J].
Bottino, Aldo ;
Capannelli, Gustavo ;
Comite, Antonio ;
Di Felice, Renzo ;
Firpo, Raffaella .
SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 59 (01) :85-90
[6]   CO2 absorption at elevated pressures using a hollow fiber membrane contactor [J].
Dindore, VY ;
Brilman, DWF ;
Feron, PHM ;
Versteeg, GF .
JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) :99-109
[7]   Evaluation of the removal of CO2 using membrane contactors: Membrane wettability [J].
El-Naas, Muftah H. ;
Al-Marzouqi, Mohamed ;
Marzouk, Sayed A. ;
Abdullatif, Nadia .
JOURNAL OF MEMBRANE SCIENCE, 2010, 350 (1-2) :410-416
[8]   Hollow fiber membrane contactors [J].
Gabelman, A ;
Hwang, ST .
JOURNAL OF MEMBRANE SCIENCE, 1999, 159 (1-2) :61-106
[9]   Analysis of CO2 separation and simulation of a partially wetted hollow fiber membrane contactor [J].
Keshavarz, R. ;
Fathikalajahi, J. ;
Ayatollahi, S. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (03) :1237-1247
[10]   A mathematical model for gas absorption membrane contactors that studies the effect of partially wetted membranes [J].
Khaisri, Sakarin ;
deMontigny, David ;
Tontiwachwuthikul, Paitoon ;
Jiraratananon, Ratana .
JOURNAL OF MEMBRANE SCIENCE, 2010, 347 (1-2) :228-239