Protection of inverter-based microgrids from ground faults by an innovative directional element

被引:9
作者
Mahamedi, Behnam [1 ]
Zhu, Jian Guo [2 ]
Eskandari, Mohsen [1 ]
Fletcher, John Edward [3 ]
Li, Li [1 ]
机构
[1] Univ Technol Sydney, Sch Elect & Data Engn, Sydney, NSW 2007, Australia
[2] Univ Sydney, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
[3] Univ New South Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
关键词
invertors; distributed power generation; power generation faults; power distribution faults; reactive power; earthing; time delay; protective schemes; zero-sequence power; zero-sequence reactive power; reverse ground faults; time domain; conventional phasor-based methods; inverter-based microgrids; innovative directional element; inverter-interfaced distributed generators; fault sensing; polarisation; faulted phase selection; zero-sequence component; IIDG-based microgrids; OVERCURRENT PROTECTION; POWER; ALGORITHM; DESIGN; COMPONENTS; CURRENTS; SCHEME;
D O I
10.1049/iet-gtd.2018.5469
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The complicated response of inverter-interfaced distributed generators (IIDG) to faults has been reported, which severely affects all parts of relaying, i.e. fault sensing and polarisation, and faulted phase selection. Given this, the root causes of difficulties in dealing with the protection of inverter-based microgrids are explained. Then, the study describes a directional element using unique features of zero-sequence components that retains satisfactory performance even in IIDG-based microgrids. The zero-sequence component is the only sequence component that can be calculated in the time domain without time delay and thus can cause less delay in the outcome of protective schemes compared with the other two sequences. With this, instantaneous zero-sequence power is defined and one term derived from it, zero-sequence reactive power, is utilised to polarise ground faults. It is proven that the zero-sequence reactive power is negative for forwarding ground faults and positive for reverse ground faults. An interesting feature is that the zero-sequence reactive power is calculated by averaging a new quantity in the time domain over half a power cycle. Hence, the time delay is half that of the conventional phasor-based methods. A sample microgrid is simulated in MATLAB/SIMULINK to evaluate the directional element and the results demonstrate the improvements.
引用
收藏
页码:5918 / 5927
页数:10
相关论文
共 56 条
[51]   Current-Only Directional Overcurrent Protection for Distribution Automation: Challenges and Solutions [J].
Ukil, Abhisek ;
Deck, Bernhard ;
Shah, Vishal H. .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (04) :1687-1694
[52]  
Voloh I., 2009, 62 ANN C PROT REL EN
[53]   Ultra-high-speed travelling wave directional protection based on electronic transformers [J].
Wang, Dong ;
Gao, Houlei ;
Zou, Guibin ;
Luo, Sibei .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (08) :2065-2074
[54]   Design and analysis of active power control strategies for distributed generation inverters under unbalanced grid faults [J].
Wang, F. ;
Duarte, J. L. ;
Hendrix, M. A. M. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (08) :905-916
[55]   Fundamental phasor calculation with short delay [J].
Yao, Ziwen .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (03) :1280-1287
[56]   Suitability analysis of practical directional algorithms for use in directional comparison bus protection based on IEC61850 process bus [J].
Zadeh, M. R. D. ;
Sidhu, T. S. ;
Klimek, A. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (02) :199-208