Determination of critical power in trained rowers using a three-minute all-out rowing test

被引:44
作者
Cheng, Ching-Feng [4 ]
Yang, Yi-Shan [3 ]
Lin, Hui-Mei [2 ]
Lee, Chia-Lun [1 ]
Wang, Chun-Yi [5 ]
机构
[1] Yu Da Univ, Dept Recreat Sports Management, Chaochiao Township 361, Miaoli, Taiwan
[2] Taipei Phys Educ Coll, Dept Sports Sci Aquat, Taipei, Taiwan
[3] Chih Ping Senior High Sch, Tao Yuan, Taiwan
[4] Natl Taiwan Normal Univ, Dept Athlet Performance, Taipei, Taiwan
[5] Natl Taiwan Normal Univ, Dept Phys Educ, Taipei, Taiwan
关键词
Exercise intensity; Exercise testing; Aerobic capacity; Indoor rowing; ANAEROBIC WORK CAPACITY; CYCLING TEST; OXYGEN-UPTAKE; STEADY-STATE; EXERCISE; HUMANS; DEFICIT;
D O I
10.1007/s00421-011-2081-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this study was to determine whether the hyperbolic relationship between power output and time to exhaustion (work - time and power - [1/time] models) could be estimated from a modified version of a three-minute all-out rowing test (3-min RT), and to investigate the test-retest reliability of the 3-min RT. Eighteen male rowers volunteered to participate in this study and underwent an incremental exercise test (IRT), three constant-work rate tests to establish the critical power (CP) and the curvature constant (W'), and two 3-min RTs against a fixed resistance to estimate the end-test power (EP) and work-done-above-EP (WEP) on a rowing ergometer. Peak (V)Over dotO(2peak) and maximal (V)Over dotO(2max)oxygen uptakes were calculated as the highest 30 s average achieved during the 3-min RT and IRT tests. The results showed that EP and WEP determinations, based on the 3-min RT, have moderate reproducibility (P = 0.002). EP (269 +/- A 39 W) was significantly correlated with CP (work - time, 272 +/- A 30 W; power - [1/time], 276 +/- A 32 W) (P = 0.000), with no significant differences observed between the EP and CP values (P = 0.474). However, WEP did not significantly correlate with W' (P = 0.254), and was significantly higher than the W' values. There was a significant correlation between the EP and CP values (P = 0.474). However, WEP did not significantly correlate with W' (P = 0.254), and was significantly higher than theW0 values. There was a significant correlation between the (V)Over dotO(2peak) (60 +/- 3 ml kg(-1) min(-1)) and (V)Over dotO(2max) (61 +/- 4 ml kg(-1) min(-1)) (P = 0.003). These results indicate that the 3- min RT has moderate reliability, and is able to appropriately estimate the aerobic capacity in rowers, particularly for the CP and (V)Over dotO(2max) parameters.
引用
收藏
页码:1251 / 1260
页数:10
相关论文
共 26 条
  • [1] Response similarities between cycle and rowing ergometry
    Barfield, JP
    Sherman, TE
    Michael, TJ
    [J]. PHYSICAL THERAPY IN SPORT, 2003, 4 (02) : 82 - 86
  • [2] Dependence of the maximal lactate steady state on the motor pattern of exercise
    Beneke, R
    Leithäuser, RM
    Hütler, M
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 2001, 35 (03) : 192 - 196
  • [3] Brooks G., 2004, EXERCISE PHYSL HUMAN, V4th
  • [4] A 3-min all-out test to determine peak oxygen uptake and the maximal steady state
    Burnley, Mark
    Doust, Jonathan H.
    Vanhatalo, Anni
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (11) : 1995 - 2003
  • [5] Estimation of critical torque using intermittent isometric maximal voluntary contractions of the quadriceps in humans
    Burnley, Mark
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2009, 106 (03) : 975 - 983
  • [6] Intensity-dependent tolerance to exercise after attaining VO2 max in humans
    Coats, EM
    Rossiter, HB
    Day, JR
    Miura, A
    Fukuba, Y
    Whipp, BJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (02) : 483 - 490
  • [7] Determination of critical power from a single test
    Dekerle, J.
    Vanhatalo, A.
    Burnley, A.
    [J]. SCIENCE & SPORTS, 2008, 23 (05) : 231 - 238
  • [8] Defining Intensity Domains from the End Power of a 3-min All-out Cycling Test
    Francis, James T., Jr.
    Quinn, Timothy J.
    Amann, Markus
    LaRoche, Dain P.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (09) : 1769 - 1775
  • [9] VARIABLE RESISTANCE ALL-OUT TEST TO GENERATE ACCUMULATED OXYGEN DEFICIT AND PREDICT ANAEROBIC CAPACITY
    GASTIN, PB
    LAWSON, DL
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1994, 69 (04): : 331 - 336
  • [10] MEASUREMENT OF ANAEROBIC CAPACITIES IN HUMANS - DEFINITIONS, LIMITATIONS AND UNSOLVED PROBLEMS
    GREEN, S
    DAWSON, B
    [J]. SPORTS MEDICINE, 1993, 15 (05) : 312 - 327