Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation

被引:134
作者
Altiok, Ertunc [1 ]
Koos, Ralf [1 ]
Schroeder, Joerg [1 ]
Brehmer, Kathrin [1 ]
Hamada, Sandra [1 ]
Becker, Michael [1 ]
Mahnken, Andreas H. [2 ]
Almalla, Mohammad [1 ]
Dohmen, Guido [3 ]
Autschbach, Ruediger [3 ]
Marx, Nikolaus [1 ]
Hoffmann, Rainer [1 ]
机构
[1] Univ Hosp RWTH Aachen, Dept Cardiol, Aachen, Germany
[2] Univ Hosp RWTH Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[3] Univ Hosp RWTH Aachen, Dept Cardiothorac Surg, Aachen, Germany
关键词
MULTISLICE COMPUTED-TOMOGRAPHY; HEART-VALVE; STENOSIS; ECHOCARDIOGRAPHY; ROOT; PROSTHESIS; EXPERIENCE; REGURGITATION; REPLACEMENT; DIMENSIONS;
D O I
10.1136/hrt.2011.223974
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Different two-dimensional (2D) and three-dimensional (3D) imaging techniques are used for procedure planning and selection of prosthesis size before transcatheter aortic valve implantation. This study sought to compare different 2D and 3D imaging techniques and determine the accuracy of 3D transoesophageal echocardiography (TEE) for accurate analysis of aortic annulus dimensions. Methods In 49 consecutive patients with severe aortic stenosis undergoing transcatheter aortic valve implantation angiography, 2D transthoracic echocardiography (TTE), 2D and 3D TEE, and dual-source CT (DSCT) were performed to determine aortic annulus diameters. TTE and 2D TEE provided only one diameter of the aortic annulus. Angiography, DSCT and 3D TEE allowed measurement of diameters in sagittal and coronal views. The distance between aortic annulus and left main coronary artery ostium was measured by angiography, DSCT and 3D TEE. Results Sagittal diameters determined by angiography, TTE, 2D TEE, 3D TEE and DSCT were smaller than coronal diameters determined by angiography, 3D TEE and DSCT. Coronal and sagittal diameters determined by 3D TEE were in high agreement with corresponding measurements by DSCT (23.60 +/- 1.89 vs 23.46 +/- 2.07 mm and 22.19 +/- 1.96 vs 22.27 +/- 2.01 mm, respectively; mean +/- SD). There was a high correlation between DSCT and 3D TEE for the definition of coronal and sagittal aortic annulus diameters (r=0.88, SEE=0.89 mm and r=0.77, SEE=1.26 mm, respectively). Correlation of 3D TEE (13.47 +/- 1.67 mm) and DSCT (13.64 +/- 1.82 mm) in the analysis of the distance between aortic annulus and left main coronary artery ostium was better (r=0.54, SEE=1.55 mm) than between angiography (14.85 +/- 3.84 mm) and DSCT (r=0.35, SEE=1.77 mm). Conclusions 3D imaging techniques should be used to evaluate aortic annulus diameters, as 2D imaging techniques, providing only a sagittal view, underestimate them. 3D TEE provides measurements of aortic annulus diameters similar to those obtained by DSCT.
引用
收藏
页码:1578 / 1584
页数:7
相关论文
共 23 条
  • [1] Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    Abdel-Wahab, Mohamed
    Zahn, Ralf
    Horack, Martin
    Gerckens, Ulrich
    Schuler, Gerhard
    Sievert, Horst
    Eggebrecht, Holger
    Senges, Jochen
    Richardt, Gert
    [J]. HEART, 2011, 97 (11) : 899 - 906
  • [2] Echocardiography for transcatheter aortic valve implantation
    Chin, Derek
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01): : I21 - I29
  • [3] Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis
    Cribier, A
    Eltchaninoff, H
    Tron, C
    Bauer, F
    Agatiello, C
    Sebagh, L
    Bash, A
    Nusimovici, D
    Litzler, PY
    Bessou, JP
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) : 698 - 703
  • [4] Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience
    Cribier, A
    Eltchaninoff, H
    Tron, C
    Bauer, F
    Agatiello, C
    Nercolini, D
    Tapiero, S
    Litzler, PY
    Bessou, JP
    Babaliaros, V
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) : 1214 - 1223
  • [5] Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function
    Delgado, Victoria
    Ng, Arnold C. T.
    van de Veire, Nico R.
    van der Kley, Frank
    Schuijf, Joanne D.
    Tops, Laurens F.
    de Weger, Arend
    Tavilla, Giuseppe
    de Roos, Albert
    Kroft, Lucia J.
    Schalij, Martin J.
    Bax, Jeroen J.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (09) : 1114 - 1123
  • [6] Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence
    Detaint, Delphine
    Lepage, Laurent
    Himbert, Dominique
    Brochet, Eric
    Messika-Zeitoun, David
    Iung, Bernard
    Vahanian, Alec
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) : 821 - 827
  • [7] Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease - The Siegburg First-in-Man Study
    Grube, Eberhard
    Laborde, Jean C.
    Gerckens, Ulrich
    Felderhoff, Thomas
    Sauren, Barthel
    Buellesfeld, Lutz
    Mueller, Ralf
    Menichelli, Maurizio
    Schmidt, Thomas
    Zickmann, Bernfried
    Iversen, Stein
    Stone, Gregg W.
    [J]. CIRCULATION, 2006, 114 (15) : 1616 - 1624
  • [8] High-resolution transthoracic real-time three-dimensional echocardiography -: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging
    Kuhl, HP
    Schreckenberg, M
    Rulands, D
    Katoh, M
    Schäfer, W
    Schummers, G
    Bücker, A
    Hanrath, P
    Franke, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) : 2083 - 2090
  • [9] Pre-Procedural Imaging of Aortic Root Orientation and Dimensions Comparison Between X-Ray Angiographic Planar Imaging and 3-Dimensional Multidetector Row Computed Tomography
    Kurra, Vikram
    Kapadia, Samir R.
    Tuzcu, E. Murat
    Halliburton, Sandra S.
    Svensson, Lars
    Roselli, Eric E.
    Schoenhagen, Paul
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (01) : 105 - 113
  • [10] Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery.
    Leon, Martin B.
    Smith, Craig R.
    Mack, Michael
    Miller, D. Craig
    Moses, Jeffrey W.
    Svensson, Lars G.
    Tuzcu, E. Murat
    Webb, John G.
    Fontana, Gregory P.
    Makkar, Raj R.
    Brown, David L.
    Block, Peter C.
    Guyton, Robert A.
    Pichard, Augusto D.
    Bavaria, Joseph E.
    Herrmann, Howard C.
    Douglas, Pamela S.
    Petersen, John L.
    Akin, Jodi J.
    Anderson, William N.
    Wang, Duolao
    Pocock, Stuart
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) : 1597 - 1607