Indoor Carbon Dioxide, Fine Particulate Matter and Total Volatile Organic Compounds in Private Healthcare and Elderly Care Facilities

被引:23
|
作者
Baudet, Alexandre [1 ,2 ]
Baures, Estelle [3 ]
Blanchard, Olivier [3 ]
Le Cann, Pierre [3 ]
Gangneux, Jean-Pierre [3 ,4 ]
Florentin, Arnaud [2 ,5 ]
机构
[1] Univ Lorraine, Fac Odontol, CHRU Nancy, F-54505 Vandoeuvre Les Nancy, France
[2] Univ Lorraine, APEMAC, F-54000 Nancy, France
[3] Univ Rennes, EHESP Sch Publ Hlth, IRSET Inst Rech Sante Environm & Travail UMR S 10, INSERM, F-35000 Rennes, France
[4] CHU Rennes, Lab Parasitol Mycol, F-35000 Rennes, France
[5] Univ Lorraine, Fac Med, CHRU Nancy, F-54505 Vandoeuvre Les Nancy, France
关键词
indoor air quality; carbon dioxide; particulate matter; total volatile organic compounds; dental offices; general practitioner offices; pharmacies; nursing homes; AIR-QUALITY; VENTILATION; AREAS; HOMES; RISK;
D O I
10.3390/toxics10030136
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Poor indoor air quality can have adverse effects on human health, especially in susceptible populations. The aim of this study was to measure the concentrations of dioxide carbon (CO2), fine particulate matter (PM2.5) and total volatile organic compounds (TVOCs) in situ in private healthcare and elderly care facilities. These pollutants were continuously measured in two rooms of six private healthcare facilities (general practitioner's offices, dental offices and pharmacies) and four elderly care facilities (nursing homes) in two French urban areas during two seasons: summer and winter. The mean CO2 concentrations ranged from 764 +/- 443 ppm in dental offices to 624 +/- 198 ppm in elderly care facilities. The mean PM2.5 concentrations ranged from 13.4 +/- 14.4 mu g/m(3) in dental offices to 5.7 +/- 4.8 mu g/m(3) in general practitioner offices. The mean TVOC concentrations ranged from 700 +/- 641 ppb in dental offices to 143 +/- 239 ppb in general practitioner offices. Dental offices presented higher levels of indoor air pollutants, associated with the dental activities. Increasing the ventilation of these facilities by opening a window is probably an appropriate method for reducing pollutant concentrations and maintaining good indoor air quality.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Source Apportionment of Personal Exposure to Fine Particulate Matter and Volatile Organic Compounds using Positive Matrix Factorization
    Pekey, Hakan
    Pekey, Beyhan
    Arslanbas, Demet
    Bozkurt, Zehra Bulut
    Dogan, Guray
    Tuncel, Gurdal
    WATER AIR AND SOIL POLLUTION, 2013, 224 (01):
  • [22] Oxides of carbon, particulate matters and volatile organic compounds impact on indoor air quality during waterpipe smoking
    A. N. Al-Dabbous
    A. R. Khan
    S. A. Al-Tamimi
    M. Shalash
    A. D. Bajoga
    M. J. Malek
    International Journal of Environmental Science and Technology, 2019, 16 : 2849 - 2854
  • [23] Oxides of carbon, particulate matters and volatile organic compounds impact on indoor air quality during waterpipe smoking
    Al-Dabbous, A. N.
    Khan, A. R.
    Al-Tamimi, S. A.
    Shalash, M.
    Bajoga, A. D.
    Malek, M. J.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2019, 16 (06) : 2849 - 2854
  • [24] Indoor levels of volatile organic compounds and formaldehyde from emission sources at elderly care centers in Korea
    Lee, Kyoungho
    Choi, Jae-Hyun
    Lee, Seokwon
    Park, Hee-Jin
    Oh, Yu-Jin
    Kim, Geun-Bae
    Lee, Woo-Seok
    Son, Bu-Soon
    PLOS ONE, 2018, 13 (06):
  • [25] Assessment of Modeled Indoor Air Concentrations of Particulate Matter, Gaseous Pollutants, and Volatile Organic Compounds Emitted from Candles
    Cattaneo, Andrea
    Tecce, Nicola
    Derudi, Marco
    Gelosa, Simone
    Nano, Giuseppe
    Cavallo, Domenico Maria
    HUMAN AND ECOLOGICAL RISK ASSESSMENT, 2014, 20 (04): : 962 - 979
  • [26] A scripted activity study of the impact of protective advice on personal exposure to ultra-fine and fine particulate matter and volatile organic compounds
    David M Stieb
    Gregory J Evans
    Kelly Sabaliauskas
    L I Chen
    Monica E Campbell
    Amanda J Wheeler
    Jeffrey R Brook
    Mireille Guay
    Journal of Exposure Science & Environmental Epidemiology, 2008, 18 : 495 - 502
  • [27] A scripted activity study of the impact of protective advice on personal exposure to ultra-fine and fine particulate matter and volatile organic compounds
    Stieb, David M.
    Evans, Gregory J.
    Sabaliauskas, Kelly
    Chen, Li
    Campbell, Monica E.
    Wheeler, Amanda J.
    Brook, Jeffrey R.
    Guay, Mireille
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2008, 18 (05) : 495 - 502
  • [28] Indoor air quality in German daycare centers - carbon dioxide (CO2), volatile organic compounds (VOC) and fine dust - LUPE 3
    Fromme, H.
    Lahrz, T.
    Burkhardt, R.
    Fembacher, L.
    Kraft, M.
    Sievering, S.
    Kadler, D.
    Dietrich, S.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2016, 76 (03): : 55 - 61
  • [29] Response of fine particulate matter to emission changes of oxides of nitrogen and anthropogenic volatile organic compounds in the Eastern United States
    Tsimpidi, Alexandra P.
    Karydis, Vlassis A.
    Pandis, Spyros N.
    Journal of the Air and Waste Management Association, 2008, 58 (11): : 1463 - 1473
  • [30] Measurement of fine particulate matter nonvolatile and semi-volatile organic material with the Sunset Laboratory Carbon Aerosol Monitor
    Grover, Brett D.
    Kleinman, Michael
    Eatough, Norman L.
    Eatough, Delbert J.
    Cary, Robert A.
    Hopke, Philip K.
    Wilson, William E.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2008, 58 (01) : 72 - 77