Diagnostic accuracy of computed tomography for colon cancer staging: A systematic review

被引:87
|
作者
Leufkens, Anke M. [1 ]
van den Bosch, Maurice A. A. J. [2 ]
van Leeuwen, Maarten S. [2 ]
Siersema, Peter D. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Gastroenterol & Hepatol, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
关键词
Cancer staging; colon cancer; computed tomography; systematic review; TNM-stage; LIVER METASTASES; CT; CARCINOMA; METAANALYSIS; STATISTICS; UTILITY;
D O I
10.3109/00365521.2011.574732
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background. Computed Tomography (CT) is a frequently used staging modality for colon cancer patients in clinical practice. Our aim was to systemically review the available literature on diagnostic accuracy of CT for TNM staging of colon cancer. Methods. A systematic review of literature was performed. PubMed was searched using MeSH terms with the following search terms: "Tomography, X-Ray Computed" or "Tomography, Spiral Computed" and Colonic Neoplasms. Studies on rectal cancer and studies without separate analyses for the colon were excluded. We identified 779 publications, of which 11 were included for review. Overall and sample-size-weight sensitivity, specificity, accuracy, true-positive, truenegative, false-positive, false-negative, positive and negative predictive values were calculated for T, N and M stages. Results. In the 11 studies, a total of 753 patients with 759 colon cancers underwent CT for staging. Sample-size-weighted sensitivity, specificity and accuracy for T-staging was 77%, 3% and 67%, respectively; for N-staging 76%, 55% and 69%, respectively; and for M-staging 85%, 98% and 95%, respectively. Additional clinical findings were reported in 59/372 (16%) patients, with 12 having a malignant and 47 a benign origin. Conclusions. While accuracy of CT for TN-staging of colon cancer is only reasonable, the real value of CT is its high accuracy to detect distant metastases.
引用
收藏
页码:887 / 894
页数:8
相关论文
共 50 条
  • [31] Diagnostic accuracy of cone-beam breast computed tomography: a systematic review and diagnostic meta-analysis
    Johannes Uhlig
    Annemarie Uhlig
    Lorenz Biggemann
    Uwe Fischer
    Joachim Lotz
    Susanne Wienbeck
    European Radiology, 2019, 29 : 1194 - 1202
  • [32] Diagnostic accuracy of multidetector row computed tomography in T- and N staging of gastric cancer with histopathologic correlation
    Hur, Jin
    Park, Mi-Suk
    Lee, Jae Hee
    Lim, Joon Seok
    Yu, Jeong-Sik
    Hong, Yoo Jin
    Kim, Ki Whang
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (03) : 372 - 377
  • [33] Computed tomography and magnetic resonance imaging in staging of uterine cervical carcinoma: a systematic review
    Bipat, S
    Glas, AS
    van der Velden, J
    Zwinderman, AH
    Bossuyt, PMM
    Stoker, J
    GYNECOLOGIC ONCOLOGY, 2003, 91 (01) : 59 - 66
  • [34] Diagnostic Accuracy of Artificial Intelligence for Detection of Rib Fracture on X-ray and Computed Tomography Imaging: A Systematic Review
    Collins, Christopher E.
    Giammanco, Peter Aldo
    Trivedi, Sunny M.
    Sarsour, Reem O.
    Kricfalusi, Mikayla
    Elsissy, Joseph G.
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2025,
  • [35] A Prospective Diagnostic Accuracy Study of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography, Multidetector Row Computed Tomography, and Magnetic Resonance Imaging in Primary Diagnosis and Staging of Pancreatic Cancer
    Kauhanen, Saila P.
    Komar, Gaber
    Seppaenen, Marko P.
    Dean, Kirsti I.
    Minn, Heikki R.
    Kajander, Sami A.
    Rinta-Kiikka, Irina
    Alanen, Kalle
    Borra, Ronald J.
    Puolakkainen, Pauli A.
    Nuutila, Pirjo
    Ovaska, Jari T.
    ANNALS OF SURGERY, 2009, 250 (06) : 957 - 963
  • [36] Accuracy of water-enema multidetector computed tomography (WE-MDCT) in colon cancer staging: a prospective study
    E. Sibileau
    Catherine Ridereau-Zins
    D. Vanel
    A. H. Pavageau
    S. Bertrais
    E. Metivier-Cesbron
    A. Venara
    C. Aubé
    Abdominal Imaging, 2014, 39 : 941 - 948
  • [37] Diagnostic Test Accuracy of Ultrasonography vs Computed Tomography for Papillary Thyroid Cancer Cervical Lymph Node Metastasis A Systematic Review and Meta-analysis
    Alabousi, Mostafa
    Alabousi, Abdullah
    Adham, Sami
    Pozdnyakov, Alex
    Ramadan, Sherif
    Chaudhari, Hanu
    Young, J. Edward M.
    Gupta, Michael
    Harish, Srinivasan
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2022, 148 (02) : 107 - 118
  • [38] Accuracy of water-enema multidetector computed tomography (WE-MDCT) in colon cancer staging: a prospective study
    Sibileau, E.
    Ridereau-Zins, Catherine
    Vanel, D.
    Pavageau, A. H.
    Bertrais, S.
    Metivier-Cesbron, E.
    Venara, A.
    Aube, C.
    ABDOMINAL IMAGING, 2014, 39 (05): : 941 - 948
  • [39] Diagnostic accuracy of EUS and CT of vascular invasion in pancreatic cancer: a systematic review
    Yang, RenBao
    Lu, ManPeng
    Qian, XiaoXing
    Chen, Jiong
    Li, Liang
    Wang, JiaWen
    Zhang, YouQian
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2014, 140 (12) : 2077 - 2086
  • [40] The diagnostic accuracy of cone beam computed tomography in detecting temporomandibular joint bony disorders: a systematic review
    Szczesniak, Marta
    Issa, Julien
    Ozturk, Irem
    Karahan, Emre
    Czajka-Jakubowska, Agata
    Orhan, Kaan
    Dyszkiewicz-Konwinska, Marta
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e292 - e301