Validation of a GEANT4 simulation of neutron stimulated emission computed tomography

被引:1
作者
Kapadia, Anuj J. [1 ]
Harrawood, Brian P. [1 ]
Tourassi, Georgia D. [1 ]
机构
[1] Duke Univ, Med Ctr, Duke Adv Imaging Labs, Durham, NC 27705 USA
来源
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2008年 / 6913卷
关键词
neutron; spectroscopy; gamma; iron-overload; NSECT; tomography; simulation; GEANT4;
D O I
10.1117/12.773196
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Neutron stimulated emission computed tomography (NSECT) is being proposed as a non-invasive technique to detect concentrations of elements in the body for diagnosis of liver iron overload. Several experiments have been conducted to investigate NSECT's ability to determine iron concentration in liver tissue and evaluate the accuracy and sensitivity of the system. While these experiments have been successful in demonstrating NSECT's capability of quantifying iron and other tissue elements in-vivo, they have been prohibitively time consuming, often requiring as much as 24 hour acquisitions for accurate quantification. Such extensive scan times limit the use of the experimental system for initial feasibility testing and optimization. As a practical alternative, GEANT4 simulations are being developed to investigate system optimization and aid further progress of the experimental technique. This work presents results of a validation study comparing the results of a GEANT4 simulation with experimental data obtained from a sample of iron. A simulation of the NSECT system is implemented in GEANT4 and used to acquire a spectrum from a simulated iron sample. Scanning is performed with a 7.5 MeV neutron beam to stimulate gamma emission from iron nuclei. The resulting gamma spectrum is acquired and reconstructed using high-purity germanium (HPGe) detectors and analyzed for energy peaks corresponding to iron. The simulated spectrum is compared with a corresponding experimental spectrum acquired with an identical source-detector-sample configuration. Five peaks are detected corresponding to gamma transitions from iron in both spectra with relative errors ranging from 4.5% to 17% for different peaks. The result validates the GEANT4 simulation as a feasible alternative to perform simulated NSECT experiments using only computational resources.
引用
收藏
页数:6
相关论文
共 18 条
  • [1] AL, ZN, CU, MN AND FE LEVELS IN BRAIN IN ALZHEIMERS-DISEASE
    ANDRASI, E
    FARKAS, E
    SCHEIBLER, H
    REFFY, A
    BEZUR, L
    [J]. ARCHIVES OF GERONTOLOGY AND GERIATRICS, 1995, 21 (01) : 89 - 97
  • [2] Bomboi Giuseppe, 2005, Ann Ist Super Sanita, V41, P205
  • [3] HEPATIC IRON OVERLOAD - DIAGNOSIS AND QUANTIFICATION BY NONINVASIVE IMAGING
    CHEZMAR, JL
    NELSON, RC
    MALKO, JA
    BERNARDINO, ME
    [J]. GASTROINTESTINAL RADIOLOGY, 1990, 15 (01): : 27 - 31
  • [4] A search for trace elements in some human intracranial tumors by instrumental neutron activation analysis
    Civit, T
    Houdayer, AJ
    Kennedy, G
    [J]. BIOLOGICAL TRACE ELEMENT RESEARCH, 2000, 74 (03) : 203 - 210
  • [5] ELYAZIGI A, 1986, CLIN CHEM, V32, P2187
  • [6] Neutron stimulated emission computed tomography: Background corrections
    Floyd, Carey E., Jr.
    Sharma, Amy C.
    Bender, Janelle E.
    Kapadia, Anuj J.
    Xia, Jessie Q.
    Harrawood, Brian P.
    Tourassi, Georgia D.
    Lo, Joseph Y.
    Kiser, Matthew R.
    Crowell, Alexander S.
    Pedroni, Ronald S.
    Macri, Robert A.
    Tajima, Shigeyuki
    Howell, Calvin R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 254 (02) : 329 - 336
  • [7] Introduction to neutron stimulated emission computed tomography
    Floyd, Carey E., Jr.
    Bender, Janelle E.
    Sharma, Amy C.
    Kapadia, Anuj
    Xia, Jessie
    Harrawood, Brian
    Tourassi, Georgia D.
    Lo, Joseph Y.
    Crowell, Alexander
    Howell, Calvin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) : 3375 - 3390
  • [8] Neutron stimulated emission computed tomography of stable isotopes
    Floyd, CE
    Howell, C
    Harrawood, B
    Crowell, A
    Kapadia, A
    Macri, R
    Xia, J
    Pedroni, R
    Bowsher, J
    Kiser, M
    Tourassi, G
    Tornow, W
    Walter, R
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 248 - 254
  • [9] AN ELEMENTAL CORRELATION STUDY IN CANCEROUS AND NORMAL BREAST-TISSUE WITH SUCCESSIVE CLINICAL STAGES BY NEUTRON-ACTIVATION ANALYSIS
    GARG, AN
    SINGH, V
    WEGINWAR, RG
    SAGDEO, VN
    [J]. BIOLOGICAL TRACE ELEMENT RESEARCH, 1994, 46 (03) : 185 - 202
  • [10] Concentrations of Fe, Cu and Zn in breast tissue: a synchrotron XRF study
    Geraki, K
    Farquharson, MJ
    Bradley, DA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13) : 2327 - 2339