ultra performance liquid chromatography;
solid-phase extraction;
tandem mass spectrometry;
environmental analysis;
surface water;
pharmaceutical;
drug;
matrix effect;
standard addition;
D O I:
10.1016/j.chroma.2008.01.064
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Herein, a new method for the detection of 13 different pharmaceuticals and one metabolite in surface water at low ng/L levels is described. The method utilizes ultra performance liquid chromatography-tandem mass spectrometry and a solid-phase extraction sample preparation. Mean method detection limits were low(4.10 ng/L and overall solid-phase extraction recovery and reproducibility was adequate (mean recovery, 77.9%; mean RSD, 7.3%). The method allows for quick run times and minimal solvent use as compared with other previously reported high performance liquid chromatography-based methods. Application of this method for the detection of pharmaceuticals in Tennessee River surface water determined that caffeine, sulfamethoxazole, and carbamazepine were frequently detected (100% of samples). Trimethoprim was moderately detected (30% of samples); acetaminophen, atorvastatin, and lovastatin were infrequently detected (10% of samples); and ciprofloxacin, diltiazem, fluoxetine, levofloxacin, norfluoxetine, ranitidine, and sertraline were not detected. This study reports the first detection of lovastatin in surface water. (C) 2008 Elsevier B.V. All rights reserved.