Autograft contamination during preparation for anterior cruciate ligament reconstruction

被引:49
作者
Hantes, Michael E.
Basdekis, Georgios K.
Varitimidis, Sokratis E.
Giotikas, Dimitrios
Petinaki, Efthimia
Malizos, Konstantinos N.
机构
[1] Univ Thessalia, Sch Med, Univ Hosp Larissa, Dept Orthopaed, Larisa, Greece
[2] Univ Thessalia, Sch Med, Univ Hosp Larissa, Dept Microbiol, Larisa, Greece
关键词
D O I
10.2106/JBJS.G.00806
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The autograft preparation process for anterior cruciate ligament reconstruction has a potential for graft contamination. The purpose of this study was to evaluate the possibility of contamination of the bone-patellar tendon-bone and hamstring tendon autograft during preparation for anterior cruciate ligament reconstruction. Methods: A primary isolated reconstruction of the anterior cruciate ligament with use of bone-patellar tendon-bone autograft (thirty patients) and hamstring tendon autograft (thirty patients) was performed in a prospective, consecutive series of patients. Three tissue samples were obtained for culture from each graft at different time-intervals during the graft preparation. In addition, the erythrocyte sedimentation rate and the C-reactive protein level were evaluated preoperatively and on the third, seventh, and twentieth postoperative days, and the clinical course of all patients was monitored. Results: The time needed for graft preparation was significantly longer for hamstring autografts (nineteen minutes) than for bone-patellar tendon-bone autografts (ten minutes) (p = 0.032). In the hamstring group, cultures of graft tissue from four patients (13%) were positive for bacteria. In the bone-patellar tendon-bone group, cultures of graft tissue from three patients (10%) were positive for bacteria; the difference between groups was not significant (p = 0.923). No patient had development of a postoperative infection. There were no differences between patients with a contaminated graft and those with an uncontaminated graft with regard to postoperative changes in the erythrocyte sedimentation rate or the C-reactive protein level at all time-intervals. Conclusions: A high rate (12%) of autograft contamination can be expected during autograft preparation for anterior cruciate ligament reconstruction. The contamination rate is almost equal for both bone-patellar tendon-bone and hamstring tendon autografts. We could not identify an association between contaminated grafts implanted in the knee and postoperative inflammatory markers such as the erythrocyte sedimentation rate and the C-reactive protein level. Level of Evidence: Therapeutic Level II. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:760 / 764
页数:5
相关论文
共 24 条
[1]   The effects of chlorhexidine irrigation solution on contaminated bone-tendon allografts [J].
Burd, T ;
Conroy, BP ;
Meyer, SC ;
Allen, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (02) :241-244
[2]  
COOPER D E, 1991, Arthroscopy, V7, P272, DOI 10.1016/0749-8063(91)90125-H
[3]   Intraoperative bacterial contamination in operations for joint replacement [J].
Davis, N ;
Curry, A ;
Gambhir, AK ;
Panigrahi, H ;
Walker, CRC ;
Wilkins, EGL ;
Worsley, MA ;
Kay, PR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :886-889
[4]   Positive culture in allograft ACL-reconstruction:: what to do? [J].
Díaz-de-Rada, P ;
Barriga, A ;
Barroso, JL ;
García-Barrecheguren, E ;
Alfonso, M ;
Valentí, JR .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (04) :219-222
[5]   CONTAMINATED RABBIT PATELLAR TENDON GRAFTS - IN-VIVO ANALYSIS OF DISINFECTING METHODS [J].
GOEBEL, ME ;
DREZ, D ;
HECK, SB ;
STOMA, MK .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :387-391
[6]   Anterior and posterior cruciate ligament reconstruction in the new millennium: a global perspective [J].
Harner, CD ;
Fu, FH ;
Irrgang, JJ ;
Vogrin, TM .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2001, 9 (06) :330-336
[7]   A survey of sports medicine specialists investigating the preferred management of contaminated anterior cruciate ligament grafts [J].
Izquierdo, R ;
Cadet, ER ;
Bauer, R ;
Stanwood, W ;
Levine, WN ;
Ahmad, CS .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (11) :1348-1353
[8]   Infections following arthroscopic anterior cruciate ligament reconstruction [J].
Judd, D ;
Bottoni, C ;
Kim, D ;
Burke, M ;
Hooker, S .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (04) :375-384
[9]  
KOHN D, 1988, Arthroscopy, V4, P287, DOI 10.1016/S0749-8063(88)80047-1
[10]  
LARSSON S, 1992, CLIN ORTHOP RELAT R, P237