Comparison of bone-implant attachment strength between the implants with hydroxyapatite-coating and tricalciumphosphate-coating on titanium arc sprayed titanium

被引:0
|
作者
Hayashi, K [1 ]
Hara, T [1 ]
Inamura, T [1 ]
Iwamoto, Y [1 ]
机构
[1] Kyushu Univ, Fac Med, Dept Orthopaed, Higashi Ku, Fukuoka 812, Japan
来源
关键词
D O I
10.1016/B978-008042692-1/50069-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compared the bone-implant attachment strength between are sprayed titanium without ceramic coating(Proarc), hydroxyapatite(HA)-coated Proarc(Proarc HA),and tricalciumphosphate(TCP)-coated Proarc(Proarc TCP) by push-out test in dog femurs,Push-out strength of Proarc-HA was significantly greater than that of Proarc(p<0.05) 4 weeks postimplantation. There was no significant difference between Proarc and Proarc TCP. There was no significant difference between Proarc HA and Proarc TCP,Combination with significant difference between three materials was not found.
引用
收藏
页码:291 / 294
页数:4
相关论文
共 50 条
  • [1] Hydroxyapatite-coating on titanium arc sprayed titanium implants
    Nakashima, Y
    Hayashi, K
    Inadome, T
    Uenoyama, K
    Hara, T
    Kanemaru, T
    Sugioka, Y
    Noda, I
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1997, 35 (03): : 287 - 298
  • [2] Effect of hydroxyapatite-coating on the bonding of bone to titanium implants in the femur of ovariectomized rats
    Hara, T
    Hayashi, K
    Nakashima, Y
    Iwamoto, Y
    BIOCERAMICS, VOL 10, 1997, : 471 - 473
  • [3] Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface
    Walsh, William R.
    Bertollo, Nicky
    Christou, Chrisopher
    Schaffner, Dominik
    Mobbs, Ralph J.
    SPINE JOURNAL, 2015, 15 (05): : 1041 - 1049
  • [4] COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF SOLID HYDROXYAPATITE AND HYDROXYAPATITE-COATED TITANIUM IMPLANTS
    HAYASHI, K
    INADOME, T
    MASHIMA, T
    SUGIOKA, Y
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (05): : 557 - 563
  • [5] Comparison of metal implants with Co-Cr-Mo and hydroxyapatite coating in bone-implant interfacial bonding strength and bone ingrowth
    Lin, Chi-Chang
    Chen, Po-Quang
    Hang, Yi-Shiong
    Cheng, Cheng-Kung
    Chueh, Shan-Chang
    Biomedical Engineering - Applications, Basis and Communications, 1994, 6 (02): : 164 - 173
  • [6] Comparison between bone-implant interfaces of microtopographically modified zirconia and titanium implants
    Thu, Myint Kyaw
    Kang, Young Suk
    Kwak, Jeong Min
    Jo, Ye-Hyeon
    Han, Jung-Suk
    Yeo, In-Sung Luke
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] Effect of hydroxyapatite containing glass coating on the bonding between bone and titanium implants
    Ishikawa, T.
    Itoh, H.
    Maruno, S.
    Iwata, H.
    Ban, S.
    Clinical Materials, 1993, 14 (04): : 277 - 285
  • [8] Porous PEEK improves the bone-implant interface compared to plasma-sprayed titanium coating on PEEK
    Torstrick, F. Brennan
    Lin, Angela S. P.
    Potter, Daniel
    Safranski, David L.
    Sulchek, Todd A.
    Gall, Ken
    Guldberg, Robert E.
    BIOMATERIALS, 2018, 185 : 106 - 116
  • [9] Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
    Weiyang Zhong
    Jianxiao Li
    Chenbo Hu
    Zhengxue Quan
    Dianming Jiang
    Scientific Reports, 11
  • [10] Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
    Zhong, Weiyang
    Li, Jianxiao
    Hu, Chenbo
    Quan, Zhengxue
    Jiang, Dianming
    SCIENTIFIC REPORTS, 2021, 11 (01)