Individualized margins in 3D conformal radiotherapy planning for lung cancer: Analysis of physiological movements and their dosimetric impacts

被引:1
|
作者
Germain, Francois [1 ]
Beaulieu, Luc [1 ]
Fortin, Andre [1 ]
机构
[1] Univ Laval, Dept Radiat Oncol, Ctr Hosp, Univ Quebec, Quebec City, PQ G1K 7P4, Canada
关键词
movements; lung tumor; radiation therapy;
D O I
10.1016/j.meddos.2007.05.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generate individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1 %. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage. (c) 2008 American Association of Medical Dosimetrists.
引用
收藏
页码:48 / 54
页数:7
相关论文
共 50 条
  • [41] Radiomics Analysis of 3D Dose Distributions to Predict Toxicity of Radiotherapy for Cervical Cancer
    Lucia, Francois
    Bourbonne, Vincent
    Visvikis, Dimitris
    Miranda, Omar
    Gujral, Dorothy M.
    Gouders, Dominique
    Dissaux, Gurvan
    Pradier, Olivier
    Tixier, Florent
    Jaouen, Vincent
    Bert, Julien
    Hatt, Mathieu
    Schick, Ulrike
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (05):
  • [42] Dosimetric comparison of 3-dimensional conformal radiotherapy (3D-CRT) and volumetric-modulated arc therapy (VMAT) in locally advanced cancer cervix
    Agrawal, Animesh
    Hadi, Rahat
    Rath, Satyajeet
    Bharati, Avinav
    Rastogi, Madhup
    Khurana, Rohini
    Sahni, Kamal
    Sapru, Shantanu
    Gandhi, Ajeet Kumar
    Srivastava, Anoop Kumar
    Mishra, Surendra Prasad
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 60 - 67
  • [43] 3D surface imaging for monitoring intrafraction motion in frameless stereotactic body radiotherapy of lung cancer
    Alderliesten, Tanja
    Sonke, Jan-Jakob
    Betgen, Anja
    van Vliet-Vroegindeweij, Corine
    Remeijer, Peter
    RADIOTHERAPY AND ONCOLOGY, 2012, 105 (02) : 155 - 160
  • [44] Reduced toxicity in the treatment of locally advanced rectal cancer: a comparison of volumetric modulated arc therapy and 3D conformal radiotherapy
    Droege, Leif Hendrik
    Weber, Hanne Elisabeth
    Guhlich, Manuel
    Leu, Martin
    Conradi, Lena-Christin
    Gaedcke, Jochen
    Hennies, Steffen
    Herrmann, Markus Karl
    Rave-Fraenk, Margret
    Wolff, Hendrik Andreas
    BMC CANCER, 2015, 15
  • [45] Implementation of 3D conformal radiotherapy technology at the National Cancer Centre Mongolia: A successful Asia-Pacific collaborative initiative
    Koh, Eng-Siew
    Gogna, Nirdosh Kumar
    Minjgee, Minjmaa
    Tsegmed, Uranchimeg
    Gonchig, Odontuya
    Vanchinbazar, Enkhtsetseg
    Erdenetuya, Yadamsuren
    Yap, Mei Ling
    Shelton, Nikki
    Ochoa, Cesar
    Ceylan, Abdurrahman
    Lowe, Toby
    Heng, Soo Min
    Scott, Alison
    Oar, Andrew
    Ward, Iain
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2021, 65 (04) : 454 - 459
  • [46] mARC preoperative rectal cancer treatments vs. 3D conformal radiotherapy. A dose distribution comparative study
    Bermudez Luna, Rocio
    de Torres Olombrada, Maria Victoria
    PLOS ONE, 2019, 14 (08):
  • [47] CONFIRMATION OF TARGET LOCALIZATION AND DOSIMETRY FOR 3D CONFORMAL RADIOTHERAPY TREATMENT PLANNING BY MR-IMAGING OF A FERROUS SULFATE GEL HEAD PHANTOM
    CHAN, MF
    AYYANGAR, KM
    MEDICAL PHYSICS, 1995, 22 (07) : 1171 - 1175
  • [48] A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer
    Dickey, Mike
    Roa, Wilson
    Drodge, Suzanne
    Ghosh, Sunita
    Murray, Brad
    Scrimger, Rufus
    Gabos, Zsolt
    MEDICAL DOSIMETRY, 2015, 40 (04) : 347 - 351
  • [49] Comparison of 3D and 4D Monte Carlo optimization in robotic tracking stereotactic body radiotherapy of lung cancer
    Chan, Mark K. H.
    Werner, Rene
    Ayadi, Miriam
    Blanck, Oliver
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (02) : 161 - 171
  • [50] Patient positioning variations to reduce dose to normal tissues during 3D conformal radiotherapy for high-risk prostate cancer
    Czigner, K.
    Agoston, P.
    Forgacs, G.
    Kasler, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (09) : 816 - 822