External Quality Assurance of Fibrinogen Assays Using Normal Plasma Results of the 2008 College of American Pathologists Proficiency Testing Program in Coagulation

被引:14
作者
Cunningham, Mark T. [1 ]
Olson, John D. [2 ]
Chandler, Wayne L. [3 ]
Van Cott, Elizabeth M. [4 ]
Eby, Charles S. [5 ]
Teruya, Jun [6 ]
Hollensead, Sandra C. [7 ]
Adcock, Dorothy M. [8 ]
Allison, Paul M. [9 ]
Kottke-Marchant, Kandice K. [10 ]
Smith, Marc D. [11 ]
机构
[1] Univ Kansas, Med Ctr, Dept Pathol, Kansas City, KS 66160 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Dept Pathol, San Antonio, TX 78229 USA
[3] Methodist Hosp, Phys Org, Dept Pathol & Lab Med, Houston, TX 77030 USA
[4] Massachusetts Gen Hosp, Dept Pathol, Boston, MA 02114 USA
[5] Washington Univ, Sch Med, Dept Pathol, St Louis, MO 63110 USA
[6] Texas Childrens Hosp, Baylor Coll Med, Dept Pathol, Houston, TX 77030 USA
[7] Univ Louisville Hosp, Dept Pathol, Louisville, KY USA
[8] Esoterix Inc, Englewood, CO USA
[9] St Lukes Episcopal Hosp, Dept Pathol, Houston, TX 77030 USA
[10] Cleveland Clin, Dept Pathol & Lab Med, Cleveland, OH 44106 USA
[11] William Beaumont Hosp, Dept Clin Pathol, Royal Oak, MI 48072 USA
关键词
FRESH-FROZEN PLASMA; COMMON CALIBRATOR; DYSFIBRINOGENEMIA; CRYOPRECIPITATE; COAGULOPATHY; GUIDELINES; DIAGNOSIS; CLAUSS; RISK;
D O I
10.5858/arpa.2011-0322-OA
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-Proper diagnosis and therapy of fibrinogen deficiency requires high-quality fibrinogen assays. Objective.-To assess the interlaboratory bias, precision, and grading of fibrinogen assays used by laboratories participating in the United States College of American Pathologists proficiency testing program in coagulation. Design.-Two identical vials of normal plasma were sent to more than 3500 laboratories. Participants measured fibrinogen levels using local methods. Results.-Fifty different fibrinogen methods were evaluated. All-method bias was 8.3% (range of method-specific biases, 0.0%-27.0%) and all-method coefficient of variation was 7.7%(range of method-specific coefficients of variation, 0.7%-25.8%). After controlling for reagent/instrument type, mean fibrinogen levels were 11.6% higher for prothrombin time-based reagents compared to Clauss (P<.001), and coefficient of variation was 46% lower for mechanical endpoint instruments compared to photo-optical. Most testing events (97.4%) could be reliably graded as pass or fail using a target range of +/- 20% from the method mean (total pass rate, 98.8%). Total fail rate was 3.0-fold lower for mechanical instruments compared to photo-optical (0.5% versus 1.5%, P=.001). Nonetheless many photo-optical methods had very high precision and very low fail rates. Conclusions.-Fibrinogen assays showed highly variable methodology and performance characteristics. Bias, precision, and grading were affected by the type of reagent or instrument used. (Arch Pathol Lab Med. 2012; 136: 789-795; doi: 10.5858/arpa.2011-0322-OA)
引用
收藏
页码:789 / 795
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 1994, JAMA, V271, P777
[2]   Pathophysiology and Treatment of Coagulopathy in Massive Hemorrhage and Hemodilution [J].
Bolliger, Daniel ;
Goerlinger, Klaus ;
Tanaka, Kenichi A. .
ANESTHESIOLOGY, 2010, 113 (05) :1205-1219
[3]  
BOVILL EG, 1993, ARCH PATHOL LAB MED, V117, P58
[4]   RESULTS OF A COLLABORATIVE STUDY FOR FIBRINOGEN MEASUREMENT - EVIDENCE THAT THE USE OF A COMMON CALIBRATOR IMPROVES INTERLABORATORY AGREEMENT [J].
CHANTARANGKUL, V ;
TRIPODI, A ;
MANNUCCI, PM .
BLOOD COAGULATION & FIBRINOLYSIS, 1994, 5 (05) :761-766
[5]   INACCURACY OF THE DERIVED FIBRINOGEN MEASUREMENT [J].
CHITOLIE, A ;
MACKIE, IJ ;
GRANT, D ;
HAMILTON, JL ;
MACHIN, SM .
BLOOD COAGULATION & FIBRINOLYSIS, 1994, 5 (06) :955-957
[6]   CLOTTING FACTOR LEVELS AND THE RISK OF DIFFUSE MICROVASCULAR BLEEDING IN THE MASSIVELY TRANSFUSED PATIENT [J].
CIAVARELLA, D ;
REED, RL ;
COUNTS, RB ;
BARON, L ;
PAVLIN, E ;
HEIMBACH, DM ;
CARRICO, CJ .
BRITISH JOURNAL OF HAEMATOLOGY, 1987, 67 (03) :365-368
[7]   Quality assurance in hemostasis: The perspective from the College of American Pathologists proficiency testing program [J].
Cunningham, Mark T. ;
Brandt, John T. ;
Chandler, Wayne L. ;
Eby, Charles S. ;
Hayes, Timothy E. ;
Krishnan, Jayashree ;
Lefkowitz, Jerry B. ;
Olson, John D. ;
Stasik, Christopher J. ;
Teruya, Jun ;
Van Cott, Elizabeth M. .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2007, 33 (03) :250-258
[8]  
Cunningham MT, 1999, ARCH PATHOL LAB MED, V123, P199
[9]  
Cunningham MT, 2002, ARCH PATHOL LAB MED, V126, P499
[10]   Congenital Fibrinogen Disorders [J].
de Moerloose, Philippe ;
Neerman-Arbez, Marguerite .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2009, 35 (04) :356-366