Study on Cavity Ring-Down Spectroscopy in High Power Ion Source

被引:4
作者
Hu Chun-dong [1 ,2 ]
Yan Jing-yang [1 ,2 ]
Wang Yan [1 ,2 ]
Liang Li-zhen [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
关键词
Cavity ring-down spectroscopy; Negative hydrogen ion; High power ion source;
D O I
10.3964/j.issn.1000-0593(2018)02-0346-06
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
High power ion source is a core component of neutral beam injector for tokamak. Negative ion source is the reference source for ITER neutral beam injection system as negative ion beam has a high neutralization efficiency in high energy. Cavity ring-down spectroscopy (CRDS) is a highly sensitive optical absorption spectroscopic technique. CRDS is able to measure the absolute line-of-sight integrated density of negative hydrogen ions based on photodetachment process. Compared with laser photodetachment method and optical emission spectroscopy, CRDS is insensitive to electromagnetic interference and doesn't need plasma parameters for calculating, thus yielding reliable results. CRDS system is composed of laser, optical cavity, detector and data acquisition system. Equipment selection principle was analyzed. The basic principle of CRDS was presented, and then the analytical form of using CRDS to measure H- density was derived in detail. CRDS has already been applied to high power ion source in laboratories of Germany, Japan and Italy. Results displayed that source parameters, including pressure and power, affected H- density. H- density increased from 1016 m(-3) magnitude to 10(17) m(-3) magnitude in Cs seeded operation. The linearity between H- density and extracted current was proved by NIFS.
引用
收藏
页码:346 / 351
页数:6
相关论文
共 12 条
[1]   Photodetachment diagnostic techniques for measuring negative ion densities and temperatures in plasmas [J].
Bacal, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (11) :3981-4006
[2]  
Christ-Koch S, 2009, PLASMA SOURCES SCI T, V18, P12
[3]   A novel diagnostic technique for H-(D-) densities in negative hydrogen ion sources [J].
Fantz, U. ;
Wuenderlich, D. .
NEW JOURNAL OF PHYSICS, 2006, 8
[4]   Negative hydrogen ion transport in RF-driven ion sources for ITER NBI [J].
Gutser, R. ;
Wuenderlich, D. ;
Fantz, U. .
PLASMA PHYSICS AND CONTROLLED FUSION, 2009, 51 (04)
[6]   Achievement of 100 s Long Pulse Neutral Beam Extraction in EAST Neutral Beam Injector [J].
Hu Chundong .
PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (03) :201-203
[7]   Comparison of Optical Emission Spectroscopy and Cavity Ring-Down Spectroscopy in Large-Scaled Negative-Ion Source [J].
Ikeda, K. ;
Nakano, H. ;
Tsumori, K. ;
Fantz, U. ;
Kaneko, O. ;
Kisaki, M. ;
Nagaoka, K. ;
Osakabe, M. ;
Takeiri, Y. .
SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES, 2011, 1390
[8]   Cavity Ring-Down System for Density Measurement of Negative Hydrogen Ion on Negative Ion Source [J].
Nakano, Haruhisa ;
Tsumori, Katsuyoshi ;
Nagaoka, Kenichi ;
Shibuya, Masayuki ;
Fantz, Ursel ;
Kisaki, Masashi ;
Ikeda, Katsunori ;
Osakabe, Masaki ;
Kaneko, Osamu ;
Asano, Eiji ;
Kondo, Tomoki ;
Sato, Mamoru ;
Komada, Seiji ;
Sekiguchi, Haruo ;
Takeiri, Yasuhiko .
SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES, 2011, 1390
[9]   CAVITY RING-DOWN OPTICAL SPECTROMETER FOR ABSORPTION-MEASUREMENTS USING PULSED LASER SOURCES [J].
OKEEFE, A ;
DEACON, DAG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (12) :2544-2551
[10]   Design of a cavity ring-down spectroscopy diagnostic for negative ion rf source SPIDER [J].
Pasqualotto, R. ;
Alfier, A. ;
Lotto, L. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10)