Treatment of radioactive decay in pharmacokinetic modeling:: Influence on parameter estimation in cardiac 13N-PET

被引:20
作者
Glatting, G [1 ]
Reske, SN [1 ]
机构
[1] Univ Ulm, Abt Nukl Med, D-89070 Ulm, Germany
关键词
modeling; parameter estimation; PET;
D O I
10.1118/1.598561
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radioactive decay during measurement can be accounted for by either a (d) under bar ecay correction of the measured data (b) under bar efore (m) under bar odeling (DbM) or by direct implementation of (d) under bar ecay (i) under bar nto the pharmacokinetic (m) under bar odel (DiM). The purpose of this study was to quantify the influence of the type of decay correction on the calculated parameters for the example of a three-compartment model used for the calculation of myocardial perfusion with N-13 ammonia and positron emission tomography (PET). For a given input function [C-a(t)proportional to t exp(-kt), k = 1.72/min] the tissue uptake for two parameter sets of K1, k2, k3, TBV were calculated for 20 frames (12 X 10 s, 3 X 30 s, 3 X 120 s, 1 X 300 s). These values were mathematically deteriorated by various noise levels according to Poisson statistics and fitted by a Levenberg-Marquardt algorithm. Estimated parameter means and coefficients of variation of the fitted parameters were calculated for the DbM and DiM case. The estimated parameter means for both decay correction methods were of comparable quality. The important measure for a single fit is the relative variability of the fitted parameters. This value is up to a factor 1.15 smaller for K-1 obtained with DiM and a reasonable noise level of 10%. Therefore, decay correction should be taken into account during modeling to reduce the variability in the fitted parameters. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00204-7].
引用
收藏
页码:616 / 621
页数:6
相关论文
共 15 条
[1]  
[Anonymous], 1989, NUMERICAL RECIPES FO
[2]   THE EFFECTS OF MEASUREMENT ERRORS IN THE PLASMA RADIOACTIVITY CURVE ON PARAMETER-ESTIMATION IN POSITRON EMISSION TOMOGRAPHY [J].
CHEN, K ;
HUANG, SC ;
YU, DC .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09) :1183-1200
[3]  
Coxson PG, 1997, J NUCL MED, V38, P660
[4]  
FENG D, 1991, BIOMED SCI INSTRUM, V27, P43
[5]   A new double modeling approach for dynamic cardiac PET studies using noise and spillover contaminated LV measurements [J].
Feng, DG ;
Li, XJ ;
Huang, SC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (03) :319-327
[6]   QUANTITATION OF MYOCARDIAL BLOOD-FLOW WITH (H2O)-O-15 AND POSITRON EMISSION TOMOGRAPHY - ASSESSMENT AND ERROR ANALYSIS OF A MATHEMATICAL APPROACH [J].
HERRERO, P ;
MARKHAM, J ;
BERGMANN, SR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (05) :862-873
[7]  
HOFFMAN E J, 1986, P237
[8]  
HUANG S-C, 1986, P287
[9]   KINETIC DATA-ANALYSIS WITH A NOISY INPUT FUNCTION [J].
HUESMAN, RH ;
MAZOYER, BM .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (12) :1569-1579
[10]   NONINVASIVE QUANTIFICATION OF REGIONAL BLOOD-FLOW IN THE HUMAN HEART USING N-13 AMMONIA AND DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING [J].
HUTCHINS, GD ;
SCHWAIGER, M ;
ROSENSPIRE, KC ;
KRIVOKAPICH, J ;
SCHELBERT, H ;
KUHL, DE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) :1032-1042