High-Quality T2-Weighted 4-Dimensional Magnetic Resonance Imaging for Radiation Therapy Applications

被引:32
作者
Du, Dongsu [1 ]
Caruthers, Shelton D. [2 ]
Glide-Hurst, Carri [3 ]
Low, Daniel A. [4 ]
Li, H. Harold [1 ]
Mutic, Sasa [1 ]
Hu, Yanle [1 ,5 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO USA
[2] Philips Healthcare, Cleveland, OH USA
[3] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI USA
[4] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[5] Mayo Clin Arizona, Dept Radiat Oncol, Phoenix, AZ 85054 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2015年 / 92卷 / 02期
基金
美国国家卫生研究院;
关键词
BREATH-HOLD TECHNIQUE; TUMOR MOTION; RESPIRATORY SURROGATE; COMPUTED-TOMOGRAPHY; GATED RADIOTHERAPY; ORGAN MOTION; LUNG-TUMORS; REGISTRATION; 4D-CT; LIVER;
D O I
10.1016/j.ijrobp.2015.01.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to improve triggering efficiency of the prospective respiratory amplitude-triggered 4-dimensional magnetic resonance imaging (4DMRI) method and to develop a 4DMRI imaging protocol that could offer T2 weighting for better tumor visualization, good spatial coverage and spatial resolution, and respiratory motion sampling within a reasonable amount of time for radiation therapy applications. Methods and Materials: The respiratory state splitting (RSS) and multi-shot acquisition (MSA) methods were analytically compared and validated in a simulation study by using the respiratory signals from 10 healthy human subjects. The RSS method was more effective in improving triggering efficiency. It was implemented in prospective respiratory amplitude-triggered 4DMRI. 4DMRI image datasets were acquired from 5 healthy human subjects. Liver motion was estimated using the acquired 4DMRI image datasets. Results: The simulation study showed the RSS method was more effective for improving triggering efficiency than the MSA method. The average reductions in 4DMRI acquisition times were 36% and 10% for the RSS and MSA methods, respectively. The human subject study showed that T2-weighted 4DMRI with 10 respiratory states, 60 slices at a spatial resolution of 1.5 x 1.5 x 3.0 mm 3 could be acquired in 9 to 18 minutes, depending on the individual's breath pattern. Based on the acquired 4DMRI image datasets, the ranges of peak-to-peak liver displacements among 5 human subjects were 9.0 to 12.9 mm, 2.5 to 3.9 mm, and 0.5 to 2.3 mm in superior-inferior, anterior-posterior, and left-right directions, respectively. Conclusions: We demonstrated that with the RSS method, it was feasible to acquire high-quality T2-weighted 4DMRI within a reasonable amount of time for radiation therapy applications. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:430 / 437
页数:8
相关论文
共 33 条
  • [1] Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT
    Beddar, A. Sam
    Kainz, Kristofer
    Briere, Tina Marie
    Tsunashima, Yoshikazu
    Pan, Tinsu
    Prado, Karl
    Mohan, Radhe
    Gillin, Michael
    Krishnan, Sunil
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (02): : 630 - 638
  • [2] 4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis
    Boldea, Vlad
    Sharp, Gregory C.
    Jiang, Steve B.
    Sarrut, David
    [J]. MEDICAL PHYSICS, 2008, 35 (03) : 1008 - 1018
  • [3] Technical note: Creating a four-dimensional model of the liver using finite element analysis
    Brock, KK
    Hollister, SJ
    Dawson, LA
    Balter, JM
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1403 - 1405
  • [4] BRYAN PJ, 1984, J ULTRAS MED, V3, P317
  • [5] Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: A feasibility study
    Cai, Jing
    Chang, Zheng
    Wang, Zhiheng
    Segars, William Paul
    Yin, Fang-Fang
    [J]. MEDICAL PHYSICS, 2011, 38 (12) : 6384 - 6394
  • [6] Characterization of lung tumors motion baseline using cone-beam computed tomography
    Gauthier, Jean-Francois
    Varfalvy, Nicolas
    Tremblay, Daniel
    Cyr, Marc-Francois
    Archambault, Louis
    [J]. MEDICAL PHYSICS, 2012, 39 (11) : 7062 - 7070
  • [7] Quantification of respiration-induced abdominal tumor motion and its impact on IMRT dose distributions
    Gierga, DP
    Chen, GTY
    Kung, JH
    Betke, M
    Lombardi, J
    Willett, CG
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (05): : 1584 - 1595
  • [8] Evaluation of two synchronized external surrogates for 4D CT sorting
    Glide-Hurst, Carri K.
    Smith, Megan Schwenker
    Ajlouni, Munther
    Chetty, Indrin J.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 117 - 132
  • [9] Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    Hanley, J
    Debois, MM
    Mah, D
    Mageras, GS
    Raben, A
    Rosenzweig, K
    Mychalczak, B
    Schwartz, LH
    Gloeggler, PJ
    Lutz, W
    Ling, CC
    Leibel, SA
    Fuks, Z
    Kutcher, GJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03): : 603 - 611
  • [10] Respiratory Amplitude Guided 4-Dimensional Magnetic Resonance Imaging
    Hu, Yanle
    Caruthers, Shelton D.
    Low, Daniel A.
    Parikh, Parag J.
    Mutic, Sasa
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (01): : 198 - 204