Characterization of wear particles generated from CoCrMo alloy under sliding wear conditions

被引:55
作者
Pourzal, R. [1 ]
Catelas, I. [2 ]
Theissmann, R. [1 ,3 ]
Kaddick, C. [4 ]
Fischer, A.
机构
[1] Univ Duisburg Essen, Fac Engn, D-47057 Duisburg, Germany
[2] Univ Ottawa, Dept Mech Engn, Ottawa, ON K1N 6N5, Canada
[3] Univ Duisburg Essen, CeNIDE, D-47057 Duisburg, Germany
[4] ENDOLAB GmbH, D-83101 Thansau Rosenheim, Germany
关键词
Wear particles; Hip joint; CoCrMo; Wear; TEM; TOTAL HIP-ARTHROPLASTY; LONG-TERM SURVIVAL; ON-METAL BEARINGS; MCKEE-FARRAR; IN-VITRO; DIGESTION PROTOCOLS; JOINT BEARINGS; PROSTHESES; DEBRIS; HYPERSENSITIVITY;
D O I
10.1016/j.wear.2010.12.045
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Biological effects of wear products (particles and metal ions) generated by metal-on-metal (MoM) hip replacements made of CoCrMo alloy remain a major cause of concern. Periprosthetic osteolysis, potential hypersensitivity response and pseudotumour formation are possible reactions that can lead to early revisions. To accurately analyse the biological response to wear particles from MoM implants, the exact nature of these particles needs to be characterized. Most previous studies used energy-dispersive X-ray spectroscopy (EDS) analysis for characterization. The present study used energy filtered transmission electron microscopy (TEM) and electron diffraction pattern analysis to allow for a more precise determination of the chemical composition and to gain knowledge of the crystalline structure of the wear particles. Particles were retrieved from two different test rigs: a reciprocating sliding wear tribometer (CoCrMo cylinder vs. bar) and a hip simulator according to ISO 14242-1 (CoCrMo head vs. CoCrMo cup). All tests were conducted in new born calf serum (30 g/l protein content). Particles were retrieved from the test medium using a previously published enzymatic digestion protocol. Particles isolated from tribometer samples had a size of 100-500 nm. Diffraction pattern analysis clearly revealed the lattice structure of strain induced hcp epsilon-martensite. Hip simulator samples revealed numerous particles of 15-30 nm and 30-80 nm size. Most of the larger particles appeared to be only partially oxidized and exhibited cobalt locally. The smallest particles were Cr2O3 with no trace of cobalt. It optically appeared that these Cr2O3 particles were flaking off the surface of larger particles that depicted a very high intensity of oxygen, as well as chromium, and only background noise of cobalt. The particle size difference between the two test rigs is likely related to the conditions of the two tribosystems, in particular the difference in the sample geometry and in the type of sliding (reciprocating vs. multidirectional). Results suggest that there may be a critical particle size at which chromium oxidation and cobalt ionization are accelerated. Since earlier studies have shown that wear particles are covered by organic residue which may act as a passive layer inhibiting further oxidation, it would suggest that this organic layer may be removed during the particle isolation process, resulting in a change of the particle chemical composition due to their pyrophoric properties. However, prior to being isolated from the serum lubricant, particles remain within the contact area of head and cup as a third-body. It is therefore possible that during that time, particles may undergo significant transformation and changes in chemical composition in the contact area of the head and cup within the tribological interface due to mechanical interaction with surface asperities. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1658 / 1666
页数:9
相关论文
共 42 条
  • [1] Bhabra G, 2009, NAT NANOTECHNOL, V4, P876, DOI [10.1038/NNANO.2009.313, 10.1038/nnano.2009.313]
  • [2] Billi Fabrizio, 2009, SAS J, V3, P133, DOI 10.1016/j.esas.2009.11.006
  • [3] Serum cobalt levels after metal-on-metal total hip arthroplasty
    Brodner, W
    Bitzan, P
    Meisinger, V
    Kaider, A
    Gottsauner-Wolf, F
    Kotz, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) : 2168 - 2173
  • [4] Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation
    Brown, Christopher
    Williams, Sophie
    Tipper, Joanne L.
    Fisher, John
    Ingham, Eileen
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2007, 18 (05) : 819 - 827
  • [5] Brown SR, 2002, CLIN ORTHOP RELAT R, P157
  • [6] The pathways of dynamic recrystallization in all-metal hip joints
    Büscher, R
    Fischer, A
    [J]. WEAR, 2005, 259 : 887 - 897
  • [7] Büscher R, 2005, PRAKT METALLOGR-PR M, V42, P15
  • [8] BUSCHER R, 2005, THESIS U DUISBURG ES
  • [9] Histological Features of Pseudotumor-like Tissues From Metal-on-Metal Hips
    Campbell, Pat
    Ebramzadeh, Edward
    Nelson, Scott
    Takamura, Karren
    De Smet, Koen
    Amstutz, Harlan C.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) : 2321 - 2327
  • [10] Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time
    Catelas, I
    Campbell, PA
    Bobyn, JD
    Medley, JB
    Huk, OL
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) : 195 - 208