Determinants of aerosolized albuterol delivery to mechanically ventilated infants

被引:23
|
作者
Coleman, DM
Kelly, HW
McWilliams, BC
机构
[1] UNIV NEW MEXICO,HLTH SCI CTR,SCH MED,COLL PHARM,ALBUQUERQUE,NM 87131
[2] UNIV NEW MEXICO,HLTH SCI CTR,SCH MED,DEPT PEDIAT,ALBUQUERQUE,NM 87131
关键词
aerosol delivery; albuterol; infant; mechanical ventilation; metered-dose inhaler; nebulizer; spacer;
D O I
10.1378/chest.109.6.1607
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
An in vitro lung model and a volume ventilator were used to evaluate the delivery of aerosolized albuterol through an infant ventilator circuit, We compared the following: continuous nebulization (CNA) and intermittent nebulization (INA); various nebulizer gas flows, 5.0, 6.5, and 8.0 L/min; and duty cycle of 33% and 50%. The efficiency and consistency of aerosol delivery by metered-dose inhaler (MDI) with four different spacer devices and by nebulizer positioned at the manifold and at the same position as the MDI were also evaluated. A volume ventilator (Servo 900B) was used with settings selected to reflect those of a moderately to severely ill 4-kg infant. A 3.5-mm endotracheal tube,vas used in all experiments, A specific type of nebulizer used (Airlife Misty Neb; Baxter; Valencia, Calif) and several spacers were studied (Aerochamber and Aerovent, Diemolding Healthcare Div, Canastota, NY; ACE, Monaghan Medical Corp, Plattsburgh, NY; and an in-line MDI adapter, Instrumentation Industries Inc, Pittsburgh). CNA delivered significantly more aerosol to the lung model (4.8+/-0.6% of the starting dose) than INA (3.8+/-0.3%; p<0.01), There was a significant stepwise decrease in aerosol delivery with increasing nebulizer flow (4.8+/-1.3% at 5.0 L/min; 3.7+/-1.1% at 6.5 L/min; and 2.7+/-1.1% at 8.0 L/min). Increasing duty cycle did not significantly affect delivery. Overall the spacers with MDI were more efficient than the nebulizer in either position delivering about twice the percentage of the starting dose than the nebulizers. All modes of delivery, except the Aerochamber, demonstrated a marked degree of variability. Most of the starting dose of albuterol either remained in the nebulizer (30.4+/-6.0% at 5.0 L/min and 25.3+/-4.1% at 8.0 L/min) or was deposited in the inspiratory tubing (34.7+/-0.7% at 5.0 L/min and 43.7+/-4.9% at 8.0 L/min) in our system. In conclusion, we have confirmed that aerosol delivery depends on the mode of delivery and the operating conditions. Although delivery with an MDI and spacer is more efficient than a nebulizer, both methods may produce high variability depending on the method or spacer used.
引用
收藏
页码:1607 / 1613
页数:7
相关论文
共 50 条
  • [21] Impact of ventilatory modes on the breathing variability in mechanically ventilated infants
    Baudin, Florent
    Wu, Hau-Tieng
    Bordessoule, Alice
    Beck, Jennifer
    Jouvet, Philippe
    Frasch, Martin G.
    Emeriaud, Guillaume
    FRONTIERS IN PEDIATRICS, 2014, 2
  • [22] An evaluation of extubation failure predictors in mechanically ventilated infants and children
    Farias, JA
    Alía, I
    Retta, A
    Olazarri, F
    Fernández, A
    Esteban, A
    Palacios, K
    Di Nunzio, L
    Fernández, G
    Bordón, A
    Berrondo, C
    Sheehan, G
    INTENSIVE CARE MEDICINE, 2002, 28 (06) : 752 - 757
  • [23] Predictors of extubation success and failure in mechanically ventilated infants and children
    Khan, N
    Brown, A
    Venkataraman, ST
    CRITICAL CARE MEDICINE, 1996, 24 (09) : 1568 - 1579
  • [24] Obstetric delivery in mechanically ventilated critically ill pregnant women
    SE Lapinsky
    JA Rojas-Suarez
    TM Crozier
    DN Vasquez
    N Barrett
    G Bourjeily
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [25] Aerosol delivery to ventilated newborn infants: historical challenges and new directions
    Jan Mazela
    Richard A. Polin
    European Journal of Pediatrics, 2011, 170 : 433 - 444
  • [26] Aerosolized drug delivery during mechanical ventilation
    Ehrmann, S.
    Guillon, A.
    Mercier, E.
    Vecellio, L.
    Dequin, P. -F.
    REANIMATION, 2012, 21 (01): : 42 - 54
  • [27] A computerized decision support system to predict the variations in the cerebral blood flow of mechanically ventilated infants
    Tehrani, Fleur T.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (10) : 1402 - 1406
  • [28] Comparison of four methods for measuring elevation of FRC in mechanically ventilated infants
    Riou, Y
    Storme, L
    Leclerc, F
    Neve, V
    Logier, R
    Lequien, P
    INTENSIVE CARE MEDICINE, 1999, 25 (10) : 1118 - 1125
  • [29] Impact of ventilatory modes on the breathing variability mechanically ventilated infants: a commentary
    Mhanna, Maroun J.
    FRONTIERS IN PEDIATRICS, 2014, 2
  • [30] Aerosol therapy in relation to retinopathy of prematurity in mechanically ventilated preterm infants
    Yang, Mei-Chin
    Hsiao, Hsiu-Feng
    Tseng, Hsiu-Li
    Chiu, Ya-Wen
    Weng, Yi-Hao
    BMC PULMONARY MEDICINE, 2019, 19 (01)