Platelet activation in newborns detected by flow-cytometry

被引:0
|
作者
Gatti, L [1 ]
Guarneri, D [1 ]
Caccamo, ML [1 ]
Gianotti, GA [1 ]
Marini, A [1 ]
机构
[1] UNIV MILAN, DIPARTIMENTO OSTETR & GINECOL L MANGIAGALLI, DIV NEONATOL, I-20122 MILAN, ITALY
来源
BIOLOGY OF THE NEONATE | 1996年 / 70卷 / 06期
关键词
platelet activation; neonates; flow-cytometry; ADP; thromboxane A(2);
D O I
暂无
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Platelet function was investigated in full-term infants on the first, the fourth and the tenth days of life and compared to normal adult controls. Platelet function was analyzed through a new cytofluorimetric technique with two murine monoclonal antibodies, PAC-1 and anti-GMP-140, directed against two membrane proteins expressed on the activated platelets' surface. The percentage of activated platelets detected with PAC-1 and anti-GMP-140 was evaluated at basal condition and after in vitro stimulation with a wear; agonist (ADP) and a strong Txa(2) analogue inducer (Li 46619). At day I platelet activation at basal condition was negligible and similar to adult controls both with PAC-1 (1.2 vs, 1.1%) and anti-GMP-140 (2.6 vs, 3.3%), On the contrary, after ADP stimulation the percentage of PAC-1-positive activated platelets was significantly reduced in neonates compared to adults (22 vs. 66%; p < 0.001) and even more after U 46619 (11 vs., 72%; p < 0.001). The percentage of anti-GMP-140-positive activated platelets behaved similarly after adding both ADP (26 vs. 46% p < 0.01) and U 46619 (37 vs. 67%,; p < 0.001). The reduced platelet activation after ADP and U 46619 persisted at day 4 both with PAC-1 and with anti-GMP-130. On the contrary, at day 10 newborn platelets analyzed with anti-GMP-140 behaved similarly to the adult ones both at basal condition and after stimulation with ADP or U 46619 (6 vs. 3% at basal. state, 42 vs. 46% after ADP addition, and 55 vs. 67% after U 46619). These data demonstrate that the reduced platelet activation present in newborns is restored by the tenth day after birth.
引用
收藏
页码:322 / 327
页数:6
相关论文
共 50 条
  • [1] PLATELET ACTIVATION DURING PREPARATION AND STORAGE OF CONCENTRATES - DETECTION BY FLOW-CYTOMETRY
    GOODALL, AH
    BLOOD COAGULATION & FIBRINOLYSIS, 1991, 2 (02) : 377 - 382
  • [2] FLOW-CYTOMETRY OF THE COMPATIBILITY OF PLATELET TRANSFUSIONS
    DITTMANN, J
    LYNEN, R
    HUMPE, A
    RIGGERT, J
    LEGLER, T
    NEUMEYER, H
    KOHLER, M
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1995, 22 : 54 - 55
  • [3] THE CLINICAL USE OF FLOW-CYTOMETRY FOR ASSESSING PLATELET ACTIVATION IN ACUTE CORONARY SYNDROMES
    BECKER, RC
    TRACY, RP
    BOVILL, EG
    MANN, KG
    AULT, K
    CORONARY ARTERY DISEASE, 1994, 5 (04) : 339 - 345
  • [4] HEMOSTATIC PARAMETERS AND PLATELET ACTIVATION BY FLOW-CYTOMETRY IN NORMAL-PREGNANCY - A LONGITUDINAL-STUDY
    GATTI, L
    TENCONI, PM
    GUARNERI, D
    BERTULESSI, C
    OSSOLA, MW
    BOSCO, P
    GIANOTTI, GA
    INTERNATIONAL JOURNAL OF CLINICAL & LABORATORY RESEARCH, 1994, 24 (04): : 217 - 219
  • [5] QUANTITATIVE-DETERMINATION OF CIRCULATING PLATELET MICROPARTICLES BY FLOW-CYTOMETRY
    YANO, Y
    KAMBAYASHI, JI
    KAWASAKI, T
    SAKON, M
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1994, 47 (01) : S13 - S19
  • [6] Effect of menopause on platelet activation markers determined by flow cytometry
    Roshan, TM
    Normah, J
    Rehman, A
    Naing, L
    AMERICAN JOURNAL OF HEMATOLOGY, 2005, 80 (04) : 257 - 261
  • [7] A FLOW CYTOMETRY METHOD FOR CHARACTERIZING PLATELET ACTIVATION
    Alzua, Brian
    Smith, Mark
    Chen, Yan
    PROCEEDINGS OF THE 2020 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2020), 2020,
  • [8] Platelet activation as a marker for in vivo prothrombotic activity:: Detection by flow cytometry
    Tomer, A
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2004, 18 (02): : 172 - 177
  • [9] Effect of atorvastatin upon platelet activation in hypercholesterolemia, evaluated by flow cytometry
    Labiós, M
    Martínez, M
    Gabriel, F
    Guiral, V
    Martínez, E
    Aznar, J
    THROMBOSIS RESEARCH, 2005, 115 (04) : 263 - 270
  • [10] FLOW-CYTOMETRY IN THE DIAGNOSIS OF CANCER
    ORFAO, A
    CIUDAD, J
    GONZALEZ, M
    LOPEZ, A
    ABAD, MDM
    BOUZA, JIP
    CRUZ, JJ
    ALONSO, AG
    MIGUEL, JFS
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1995, 55 : 145 - 152