Clinical Significance of Tear Menisci in Dry Eye

被引:29
作者
Li, Jianhua [1 ,3 ]
Shen, Meixiao [1 ]
Wang, Jianhua [2 ]
Ma, Huixiang [1 ]
Tao, Aizhu [1 ]
Xu, Suzhong [1 ]
Lu, Fan [1 ]
机构
[1] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou 325027, Zhejiang, Peoples R China
[2] Univ Miami, Bascom Palmer Eye Inst, Miami, FL USA
[3] Affiliated Hosp N Sichuan Med Collage, Dept Ophthalmol, Nanchong, Sichuan, Peoples R China
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2012年 / 38卷 / 03期
关键词
Tear menisci; Dry eye; Real-time OCT; OPTICAL COHERENCE TOMOGRAPHY; ARTIFICIAL TEARS; OCULAR SURFACE; DIAGNOSIS; MENISCOMETRY; INSTILLATION; HEIGHT;
D O I
10.1097/ICL.0b013e318252ce0c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the relationships among tear menisci variables and clinical tests used in the diagnosis of dry eye patients. Methods: Dry eye patients (n=50; age, 35.2 years) and healthy subjects (n=48; age, 33.3 years) were recruited. Upper and lower tear menisci were imaged noninvasively by optical coherence tomography (OCT) immediately after normal and delayed blinking in both eyes. Tear meniscus heights, areas, and radius of curvatures were obtained by custom software. Tear film break-up time was measured by fluorescein (fluorescein film tear break-up time, FTBUT) and tearscope (noninvasive tear film break-up time), ocular surface vital staining was evaluated with fluorescein (FS), and secretion was measured by Schirmer I test without and with anesthesia. Results: In dry eye patients, all lower tear meniscus variables during normal blinking were correlated with all clinical tests except Schirmer I test without anesthesia. Upper tear meniscus variables were correlated with FTBUT and Schirmer I test with anesthesia. During delayed blinking, upper and lower tear menisci variables were correlated with Schirmer I test without anesthesia and FS; however, there were no correlations between menisci variables and FTBUT or Schirmer I test with anesthesia. In healthy subjects, only lower meniscus variables were correlated with Schirmer I test with anesthesia during normal blinking. During delayed blinking, the lower meniscus variables were correlated with only the Schirmer I test without anesthesia. Conclusions: Lower tear menisci were correlated more strongly with the clinical tests than were upper menisci. The tear menisci were associated with the basic tear secretion during normal blinking. Delayed blinking may affect reflex tearing levels.
引用
收藏
页码:183 / 187
页数:5
相关论文
共 20 条
[1]   Strip meniscometry: A new and simple method of tear meniscus evaluation [J].
Dogru, Murat ;
Ishida, Katsushi ;
Matsumoto, Yukihiro ;
Goto, Eiki ;
Ishioka, Misaki ;
Kojima, Takashi ;
Goto, Tateki ;
Saeki, Megumi ;
Tsubota, Kazuo .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (05) :1895-1901
[2]  
Doughty Michael J, 2002, Cont Lens Anterior Eye, V25, P57, DOI 10.1016/S1367-0484(01)00005-4
[3]  
Golding TR, 1997, CORNEA, V16, P649
[4]   Application of Visante Optical Coherence Tomography Tear Meniscus Height Measurement in the Diagnosis of Dry Eye Disease [J].
Ibrahim, Osama M. A. ;
Dogru, Murat ;
Takano, Yoji ;
Satake, Yoshiyuki ;
Wakamatsu, Tais Hitomi ;
Fukagawa, Kazumi ;
Tsubota, Kazuo ;
Fujishima, Hiroshi .
OPHTHALMOLOGY, 2010, 117 (10) :1923-1929
[5]   Temporal changes in the tear menisci following a blink [J].
Johnson, Michael E. ;
Murphy, Paul J. .
EXPERIMENTAL EYE RESEARCH, 2006, 83 (03) :517-525
[6]   A comparative study to assess the clinical use of Fluorescein Meniscus Time (FMT) with Tear Break up Time (TBUT) and Schirmer's tests (ST) in the diagnosis of dry eyes [J].
Kallarackal, GU ;
Ansari, EA ;
Amos, N ;
Martin, JC ;
Lane, C ;
Camilleri, JP .
EYE, 2002, 16 (05) :594-600
[7]   Quantitative evaluation of tear meniscus height from fluorescein photographs [J].
Kawai, Masataka ;
Yamada, Masakazu ;
Kawashima, Motoko ;
Inoue, Makoto ;
Goto, Eiki ;
Mashima, Yukihiko ;
Tsubota, Kazuo .
CORNEA, 2007, 26 (04) :403-406
[8]   Prevalence of dry eye among an elderly chinese population in Taiwan - The Shihpai eye study [J].
Lin, PY ;
Tsai, SY ;
Cheng, CY ;
Liu, JH ;
Chou, P ;
Hsu, WM .
OPHTHALMOLOGY, 2003, 110 (06) :1096-1101
[9]   Tear meniscus measurement in the diagnosis of dry eye [J].
Mainstone, JC ;
Bruce, AS ;
Golding, TR .
CURRENT EYE RESEARCH, 1996, 15 (06) :653-661
[10]   EFFECT OF FLUORESCEIN INSTILLATION ON THE PRE-CORNEAL TEAR FILM STABILITY [J].
MENGHER, LS ;
BRON, AJ ;
TONGE, SR ;
GILBERT, DJ .
CURRENT EYE RESEARCH, 1985, 4 (01) :9-12