Topological Placement of Quality Sensors in Water-Distribution Networks without the Recourse to Hydraulic Modeling

被引:57
作者
Giudicianni, C. [1 ,2 ]
Herrera, M. [3 ]
Di Nardo, A. [1 ,2 ,4 ]
Greco, R. [1 ,2 ]
Creaco, E. [2 ,5 ]
Scala, A. [4 ]
机构
[1] Univ Campania Luigi Vanvitelli, Dipartimento Ingn, Via Roma 29, I-81031 Aversa, Italy
[2] EU, European Innovat Partnership Water, Act Grp CTRL SWAN, Via Roma 29, I-81031 Aversa, Italy
[3] Univ Cambridge, Dept Engn, Inst Mfg, 17 Charles Babbage Rd, Cambridge CB3 0FS, England
[4] Italian Natl Res Council, Inst Complex Syst, Via Taurini 19, I-00185 Rome, Italy
[5] Univ Pavia, Dipartimento Ingn Civile & Architettura, Via Ferrata 3, I-27100 Pavia, Italy
关键词
Water network protection; Contamination warning system; Sensor placement; Topological centrality; CONTAMINATION WARNING SYSTEMS; MONITORING STATIONS; STRATEGIES; DESIGN; OPTIMIZATION;
D O I
10.1061/(ASCE)WR.1943-5452.0001210
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The detection of contaminant intrusion into a water-distribution network (WDN) is a difficult issue due to uncertainty related to the type of injected contaminant, source location, and intrusion time. The placement of water quality sensors has received increasing interest in the last years, and it still represents an open problem and a great challenge for researchers and utilities. Efficient numerical techniques are needed to support any contamination warning system (CWS) design. These require a well-calibrated hydraulic model of the WDN and a great deal of information, both of which are often unavailable to water utilities. In addition, as the size of the WDN increases, the choice of effective sensor placement becomes a computationally intractable problem. This paper introduces a methodology to support water utilities in the design of an effective CWS without any use of hydraulic information, but just exploiting the knowledge of the topology of the WDN. To ensure a complete coverage of the network, the method relies on a priori clustering of the WDN and on the installation of quality sensors at the most central nodes of each cluster, selected according to different topological centrality metrics. The procedure is tested on a benchmark network and on a real WDN serving a town close to Naples, Italy. The solutions obtained with topological criteria are effective in terms of detection time, detection likelihood, redundancy, and population exposed through ingestion.
引用
收藏
页数:12
相关论文
共 70 条
[1]   A state-of-the-art review of an optimal sensor placement for contaminant warning system in a water distribution network [J].
Adedoja, Oluwaseye S. ;
Hamam, Yskandar ;
Khalaf, Baset ;
Sadiku, Rotimi .
URBAN WATER JOURNAL, 2018, 15 (10) :985-1000
[2]  
[Anonymous], 2005, P WORLD WAT ENV RES
[3]  
[Anonymous], 2009, WORLD ENV WAT RES C, DOI DOI 10.1061/(ASCE)WR.1943-5452.0000187
[4]  
[Anonymous], 2006, P 8 ANN WAT DISTR SY
[5]  
[Anonymous], EPA600R076
[6]  
[Anonymous], 2006, P 8 ANN WAT DISTR SY
[7]  
[Anonymous], ARTIFICIAL INTELLIGE
[8]  
[Anonymous], 2008, P WATER DISTRIBUTION
[9]  
[Anonymous], 2006, P 8 ANN WAT DISTR SY
[10]  
[Anonymous], 2004, CRITICAL TRANSITIONS, DOI DOI 10.1061/40737(2004)481