Analysis of axial scanning range and magnification variation in wide-field microscope for measurement using an electrically tunable lens

被引:15
|
作者
Qu, Yufu [1 ]
Hu, Yongbo [1 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Dept Measurement Technol & Instrument, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
axial scanning range; liquid lens; magnification variation; wide-field microscope for measurement;
D O I
10.1002/jemt.23113
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Inserting an electrically tunable lens (ETL), such as liquid lens or tunable acoustic gradient lens, into a microscope can enable fast axial scanning, autofocusing, and extended depth of field. However, placing the ETL at different positions has different influences on image quality. Specially, in a wide-field microscope for measurement, the magnification has to be constant when introducing an ETL, otherwise it will affect measurement accuracy. To determine the best position of ETL, axial scanning range and magnification variation are quantitatively analyzed and discussed in finite and infinite microscopes through theoretical analysis, optical simulation, and experiment for four configurations: when ETL is placed at the back focal plane of objective, at the conjugate plane of objective's back focal plane between two relay lenses, or behind two relay lenses, and at imaging detector plane. The obtained results are as follows. When ETL is placed at the back focal plane, the system has a large scanning range, but the magnification varies because the back focal plane is inside the objective. When ETL is placed between two relay lenses, the magnification stays constant, but the scanning range is small. When ETL is placed behind two relay lenses, the magnification keeps invariant and the scanning range is large, but ETL and two relay lenses are inside the microscope and the system has to be customized. Finally, when ETL is placed at imaging detector plane, the magnification stays constant, but the scanning range is 0, which means the system has no axial scanning capability.
引用
收藏
页码:101 / 113
页数:13
相关论文
共 8 条
  • [1] Optical axial scanning in confocal microscopy using an electrically tunable lens
    Jabbour, Joey M.
    Malik, Bilal H.
    Olsovsky, Cory
    Cuenca, Rodrigo
    Cheng, Shuna
    Jo, Javier A.
    Cheng, Yi-Shing Lisa
    Wright, John M.
    Maitland, Kristen C.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (02): : 645 - 652
  • [2] Using Electrically Tunable Lens to Improve Axial Resolution and Imaging Field in Light Sheet Fluorescence Microscope
    Zhai, Muyue
    Huang, Xiaoshuai
    Mao, Heng
    Zhu, Qiudong
    Wang, Shanshan
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SENSING AND IMAGING, 2019, 506 : 411 - 419
  • [3] A Fully Electronic Confocal Microscope Using a Digital Micromirror Device and an Electrically Tunable Lens for 3D Measurement
    Kim, Sung Hyun
    Ko, Min Sung
    Shin, Jae Hun
    Yu, Jin Sun
    Oh, Cha-Hwan
    CURRENT OPTICS AND PHOTONICS, 2024, 8 (06)
  • [4] Large depth-of-field 3D shape measurement using an electrically tunable lens
    Hu, Xiaowei
    Wang, Guijin
    Zhang, Yujin
    Yang, Huazhong
    Zhang, Song
    OPTICS EXPRESS, 2019, 27 (21) : 29697 - 29709
  • [5] Colorful 3D Reconstruction and an Extended Depth of Field for a Monocular Biological Microscope Using an Electrically Tunable Lens
    Cheng, Yang
    Liu, Mengyao
    Ou, Yangqi
    Liu, Lin
    Hao, Qun
    BIOMIMETICS, 2024, 9 (01)
  • [6] Enhanced Axial Resolution of Wide-Field Two-Photon Excitation Microscopy by Line Scanning Using a Digital Micromirror Device
    Park, Jong Kang
    Rowlands, Christopher J.
    So, Peter T. C.
    MICROMACHINES, 2017, 8 (03):
  • [7] High-speed 3-D measurement with a large field of view based on direct-view confocal microscope with an electrically tunable lens
    Jeong, Hyeong-jun
    Yoo, Hongki
    Gweon, DaeGab
    OPTICS EXPRESS, 2016, 24 (04): : 3806 - 3816
  • [8] Single-Molecule Fluorescence Lifetime Imaging Using Wide-Field and Confocal-Laser Scanning Microscopy: A Comparative Analysis
    Oleksiievets, Nazar
    Mathew, Christeena
    Thiele, Jan Christoph
    Gallea, Jose Ignacio
    Nevskyi, Oleksii
    Gregor, Ingo
    Weber, Andre
    Tsukanov, Roman
    Enderlein, Joerg
    NANO LETTERS, 2022, 22 (15) : 6454 - 6461