Estimating subjective evaluation of low-contrast resolution using convolutional neural networks

被引:4
作者
Doi, Yujiro [1 ]
Teramoto, Atsushi [2 ]
Yamada, Ayumi [2 ]
Kobayashi, Masanao [2 ]
Saito, Kuniaki [2 ]
Fujita, Hiroshi [3 ]
机构
[1] Fujita Hlth Univ Hosp, Dept Radiol, 1-98 Dengakugakubo,Kutsukake Cho, Toyoake, Aichi 4701192, Japan
[2] Fujita Hlth Univ, Grad Sch Med Sci, 1-98 Dengakugakubo,Kutsukake Cho, Toyoake, Aichi 4701192, Japan
[3] Gifu Univ, Fac Engn, 1-1 Yanagido, Gifu, Gifu 5011194, Japan
关键词
Image quality; Computed tomography; Deep learning; Convolutional neural network; Subjective evaluation; FILTERED BACK-PROJECTION; IMAGE QUALITY; CT; RECONSTRUCTION; SAFIRE;
D O I
10.1007/s13246-021-01062-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To develop a convolutional neural network-based method for the subjective evaluation of computed tomography (CT) images having low-contrast resolution due to imaging conditions and nonlinear image processing. Four radiological technologists visually evaluated CT images that were reconstructed using three nonlinear noise reduction processes (AIDR 3D, AIDR 3D Enhanced, AiCE) on a CT system manufactured by CANON. The visual evaluation consisted of two items: low contrast detectability (score: 0-9) and texture pattern (score: 1-5). Four AI models with different convolutional and max pooling layers were constructed and trained on pairs of CANON CT images and average visual assessment scores of four radiological technologists. CANON CT images not used for training were used to evaluate prediction performance. In addition, CT images scanned with a SIEMENS CT system were input to each AI model for external validation. The mean absolute error and correlation coefficients were used as evaluation metrics. Our proposed AI model can evaluate low-contrast detectability and texture patterns with high accuracy, which varies with the dose administered and the nonlinear noise reduction process. The proposed AI model is also expected to be suitable for upcoming reconstruction algorithms that will be released in the future.
引用
收藏
页码:1285 / 1296
页数:12
相关论文
共 24 条
  • [1] Abadi M, 2016, PROCEEDINGS OF OSDI'16: 12TH USENIX SYMPOSIUM ON OPERATING SYSTEMS DESIGN AND IMPLEMENTATION, P265
  • [2] Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the Liver
    Baker, Mark E.
    Dong, Frank
    Primak, Andrew
    Obuchowski, Nancy A.
    Einstein, David
    Gandhi, Namita
    Herts, Brian R.
    Purysko, Andrei
    Remer, Erick
    Vachani, Neil
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) : 8 - 18
  • [3] Chollet F., 2018, DEEP LEARNING WITH R
  • [4] Unenhanced helical CT using increased pitch for suspected renal colic: An effective technique for radiation dose reduction?
    Diel, J
    Perlmutter, S
    Venkataramanan, N
    Mueller, R
    Lane, MJ
    Katz, DS
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (05) : 795 - 801
  • [5] Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study
    Heyer, Christoph M.
    Mohr, Patrick S.
    Lemburg, Stefan P.
    Peters, Soeren A.
    Nicolas, Volkmar
    [J]. RADIOLOGY, 2007, 245 (02) : 577 - 583
  • [6] Blind Image Quality Assessment via Deep Learning
    Hou, Weilong
    Gao, Xinbo
    Tao, Dacheng
    Li, Xuelong
    [J]. IEEE TRANSACTIONS ON NEURAL NETWORKS AND LEARNING SYSTEMS, 2015, 26 (06) : 1275 - 1286
  • [7] Robustness of Deep Learning Algorithm to Varying Imaging Conditions in Detecting Low Contrast Objects in Computed Tomography Phantom Images: In Comparison to 12 Radiologists
    Kim, Hae Young
    Lee, Kyeorye
    Chang, Won
    Kim, Youngjune
    Lee, Sungsoo
    Oh, Dong Yul
    Sunwoo, Leonard
    Lee, Yoon Jin
    Kim, Young Hoon
    [J]. DIAGNOSTICS, 2021, 11 (03)
  • [8] Deep Learning of Human Visual Sensitivity in Image Quality Assessment Framework
    Kim, Jongyoo
    Lee, Sanghoon
    [J]. 30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, : 1969 - 1977
  • [9] Feasibility of low-radiation-dose CT for abdominal examinations with hybrid iterative reconstruction algorithm: Low-contrast phantom study
    Kondo M.
    Hatakenaka M.
    Higuchi K.
    Fujioka T.
    Shirasaka T.
    Nakamura Y.
    Nakamura K.
    Yoshiura T.
    Honda H.
    [J]. Radiological Physics and Technology, 2013, 6 (2) : 287 - 292
  • [10] Automated OCT angiography image quality assessment using a deep learning algorithm
    Lauermann, J. L.
    Treder, M.
    Alnawaiseh, M.
    Clemens, C. R.
    Eter, N.
    Alten, F.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (08) : 1641 - 1648