Electrical impedance-based biopsy for prostate cancer detection

被引:0
|
作者
Mishra, Vaishali [1 ]
Bouyad, Hamza [1 ]
Halter, Ryan J. [1 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
来源
2011 IEEE 37TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC) | 2011年
关键词
prostate cancer; biopsy; electrical impedance; spectroscopy; Impedance;
D O I
暂无
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Currently biopsy is considered the gold standard for diagnosis of prostate cancer in humans, although it samples only 19mm(3) volume of prostate, corresponding to 0.95% of a 50cm(3) prostate gland for a regular 12-core biopsy procedure. The aim of this study was to increase the sampling volume by incorporating electrical impedance spectroscopy (EIS) into the standard biopsy needle. Electrical impedance can act as a reliable biomarker for distinguishing malignant from benign tissues in human prostate. The EIS biopsy needle allows tip of the needle to act as sensor to measure the electrical impedance of the tissue core extracted. The sensitivity of the prototype device was evaluated in a series of saline bath experiments. We demonstrated that EIS biopsy needle senses 286.92 mm(3) of volume of the tissue on either side of the needle trajectory for each core, adding up to 2 X 12 X 286.92 = 6886.08 mm(3) or 13.8% of tissue's volume. Thus, measuring electrical properties in addition to core extraction is expected to enhance the sensitivity and specificity of the device. A few experiments have been conducted on ex vivo porcine samples to envisage EIS biopsy needle's ability in distinguishing two different kinds of tissues.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Impedance-based fault detection methodology for rotating machines
    Ap Cavalini, Aldemir, Jr.
    Finzi Neto, Roberto Mendes
    Steffen, Valder, Jr.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2015, 14 (03): : 228 - 240
  • [22] An Impedance-Based Islanding Detection Method for DC Grids
    Paz, Francisco
    Ordonez, Martin
    2018 9TH IEEE INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2018,
  • [23] On the Effectiveness of Impedance-Based Fingerprint Presentation Attack Detection
    Kolberg, Jascha
    Glaesner, Daniel
    Breithaupt, Ralph
    Gomez-Barrero, Marta
    Reinhold, Joerg
    von Twickel, Arndt
    Busch, Christoph
    SENSORS, 2021, 21 (17)
  • [24] PZT impedance-based damage detection for civil infrastructures
    Zhu, Hong-Ping
    Wang, Dan-Sheng
    Chen, Xiao-Qiang
    STRUCTURAL CONDITION ASSESSMENT, MONITORING AND IMPROVEMENT, VOLS 1 AND 2, 2007, : 893 - 899
  • [25] An Impedance-Based Immunosensor for the Detection of Ovalbumin in White Wine
    Calabrese, Alessia
    Capo, Alessandro
    Capaccio, Angela
    Agovino, Elettra
    Varriale, Antonio
    Pascale, Michelangelo
    D'Auria, Sabato
    Staiano, Maria
    BIOSENSORS-BASEL, 2023, 13 (07):
  • [26] Impedance-based ventilation detection during cardiopulmonary resuscitation
    Risdal, Martin
    Aase, Sven Ole
    Stavland, Mette
    Eftestol, Trygve
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (12) : 2237 - 2245
  • [27] Transrectal electrical impedance tomography of the prostate: Spatially coregistered pathological findings for prostate cancer detection
    Wan, Yuqing
    Borsic, Andrea
    Heaney, John
    Seigne, John
    Schned, Alan
    Baker, Michael
    Wason, Shaun
    Hartov, Alex
    Halter, Ryan
    MEDICAL PHYSICS, 2013, 40 (06)
  • [28] Impedance-based biosensors
    Huang, X
    Greve, DW
    Nausieda, I
    Nguyen, D
    Domach, MM
    NANOENGINEERED ASSEMBLIES AND ADVANCED MICRO/NANOSYSTEMS, 2004, 820 : 241 - 247
  • [30] A feasibility study of magnetic resonance electrical impedance tomography for prostate cancer detection
    Liu, Yang
    Zhang, Yingchun
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (04) : 567 - 581