Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate

被引:259
作者
Bhagoria, JL
Saini, JS [1 ]
Solanki, SC
机构
[1] Univ Roorkee, Dept Mech & Ind Engn, Roorkee 247667, Uttar Pradesh, India
[2] MACT, REC, Dept Mech Engn, Bhopal 462007, India
关键词
solar air heater; heat transfer; friction;
D O I
10.1016/S0960-1481(01)00057-X
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
As is well known. the heat transfer coefficient of a solar air heater duct can be increased by providing artificial roughness on the heated wall (i.e. the absorber plate). Experiments were performed to collect heat transfer and friction data for forced convection flow of air in solar air heater rectangular duct with one broad wall roughened by wedge shaped transverse integral ribs. The experiment encompassed the Reynolds number range from 3000 to 18000; relative roughness height 0.015 to 0.033 the relative roughness pitch 60.17 phi (-1.0264) < ple < 12.12; and rib wedge angle (phi) of 8, 10, 12 and 15 degrees. The effect of parameters on the heat transfer coefficient and friction factor are compared with the result of smooth duct under similar flow conditions. Statistical correlations for the Nusselt number and friction factor have been developed in terms of geometrical parameters of the roughness elements and the flow Reynolds number. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:341 / 369
页数:29
相关论文
共 24 条
[1]  
Bhatti M.S., 1987, HDB SINGLE PHASE CON
[2]  
Dipprey D.F., 1963, Int. J. Heat Mass Transfer, V6, P329, DOI [10.1016/0017-9310(63)90097-8, DOI 10.1016/0017-9310(63)90097-8]
[3]  
EDWARDS FJ, 1961, ASME, P415
[4]  
EHLINGER AH, 1950, KENTS MECH ENG HDB, V1
[5]  
EMERSON WH, 1966, P 3 INT HEAT TRANSF, P267
[6]  
GUPTA D, 1993, THESIS UOR ROORKEE
[7]   DEVELOPING HEAT-TRANSFER IN RECTANGULAR CHANNELS WITH RIB TURBULATORS [J].
HAN, JC ;
PARK, JS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (01) :183-195
[8]   HIGH-PERFORMANCE HEAT-TRANSFER DUCTS WITH PARALLEL BROKEN AND V-SHAPED BROKEN RIBS [J].
HAN, JC ;
ZHANG, YM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (02) :513-523
[9]  
HAN JC, 1984, T ASME, V106, P774
[10]  
HOLMAN JP, 1971, EXPT METHODS ENG SCI