Electrolyte-gated transistor for CO2 gas detection at room temperature

被引:14
作者
Ersoez, Bora [1 ,2 ]
Schmitt, Katrin [1 ,3 ]
Woellenstein, Jurgen [1 ,3 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn IMTEK, Freiburg, Germany
[2] Robert Bosch South East Asia Pte Ltd, Corp Res, Singapore, Singapore
[3] Fraunhofer Inst Phys Measurement Tech IPM, Freiburg, Germany
关键词
Ionic liquid; Gas sensing; Carbon dioxide; Electrolyte-gated transistor; Metal oxide; Indium oxide; IONIC LIQUIDS; OXIDE; SENSORS; NANOPARTICLES; MEMBRANE; FILM;
D O I
10.1016/j.snb.2020.128201
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The availability of a low-cost CO2 sensor with small package size and low power consumption is crucial to enter market for consumer application. This study is set out to deliver proof-of-concept and a hypothetical mechanism for a new CO2 sensing concept based on an electrolyte-gated transistor (EGT), which consists of the n-semi-conducting metal oxide (MOX) In2O3 as channel-forming layer and ionic liquid (IL) [EMIM][BF4] as electrolyte. Gas measurements were performed under typical conditions for indoor and outdoor air quality evaluation, i.e. CO2 in the range 400-4000 ppm. The device behavior was reversible with response and recovery times (t(90)) of about 20 s in DC mode. Channel conductivity showed a linear CO2 sensitivity of 0.1 %/ppm and resolution <= 200 ppm at low CO2 concentrations (<= 1200 ppm). Fitting to the Clifford-Tuma model yielded a sensitivity coefficient of 175ppm(-1) in the CO2 range 0-4000 ppm. The sensing mechanism is most likely based on simultaneous electrochemical reactions of H2O, O-2, CO2. Basically, the CO2 sensitivity originates from the depletion of O-2 in proximity to MOX, which leads to an amplified electrical current. The presented CO2 detection principle synergistically combines advantages of several device classes: Sensitivity of transistors, selectivity of electrochemical sensors, and simplicity of chemiresistors.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Detection of room air contamination of angiographic CO2 with use of a gas analyzer
    Culp, WC
    Culp, WC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (07) : 735 - 737
  • [42] Polytetrafluoroethylene bindered hematite (α-Fe2O3) nanostructure for ammonia gas detection at room temperature
    Madusanka, H. T. D. S.
    Samarasekara, P.
    Fernando, C. A. N.
    MATERIALS RESEARCH EXPRESS, 2018, 5 (12):
  • [43] Facile fabrication of an electrolyte-gated In2O3 nanoparticle-based thin-film transistor uniting laser ablation and inkjet printing
    Hassan, Basem
    Liang, You
    Yong, Jason
    Yu, Yang
    Ganesan, Kumaravelu
    Walla, Andrew
    Evans, Robin
    Chana, Gursharan
    Nasr, Babak
    Skafidas, Efstratios
    FLEXIBLE AND PRINTED ELECTRONICS, 2018, 3 (04):
  • [44] Low-picomolar, label-free procalcitonin analytical detection with an electrolyte-gated organic field-effect transistor based electronic immunosensor
    Seshadri, Preethi
    Manoli, Kyriaki
    Schneiderhan-Marra, Nicole
    Anthes, Uwe
    Wierzchowiec, Piotr
    Bonrad, Klaus
    Di Franco, Cinzia
    Torsi, Luisa
    BIOSENSORS & BIOELECTRONICS, 2018, 104 : 113 - 119
  • [45] Room Temperature CO2 Detection using Interdigitated Capacitors with Heteropolysiloxane Sensing Films
    Kim, Choongsoon
    Pavlidis, Spyridon
    Kim, Min-gu
    Brand, Oliver
    Chen, Hang
    2016 IEEE SENSORS, 2016,
  • [46] Label-free C-reactive protein electronic detection with an electrolyte-gated organic field-effect transistor-based immunosensor
    Magliulo, Maria
    De Tullio, Donato
    Vikholm-Lundin, Inger
    Albers, Willem M.
    Munter, Tony
    Manoli, Kyriaki
    Palazzo, Gerardo
    Torsi, Luisa
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (15) : 3943 - 3952
  • [47] Role of H2O for CO2 Reduction Reactions at Platinum/Electrolyte Interfaces in Imidazolium Room-Temperature Ionic Liquids
    Ratschmeier, Bjoern
    Kemna, Andre
    Braunschweig, Bjoern
    CHEMELECTROCHEM, 2020, 7 (07) : 1765 - 1774
  • [48] Versatile transduction scheme based on electrolyte-gated organic field-effect transistor used as immunoassay readout system
    Piro, Benoit
    Wang, Dengjun
    Benaoudia, Dihia
    Tibaldi, Alexandra
    Anquetin, Guillaume
    Noel, Vincent
    Reisberg, Steeve
    Mattana, Giorgio
    Jackson, Brianna
    BIOSENSORS & BIOELECTRONICS, 2017, 92 : 215 - 220
  • [49] Metal-Free Fully Solution-Processable Flexible Electrolyte-Gated Carbon Nanotube Field Effect Transistor
    Bhatt, Vijay Deep
    Joshi, Saumya
    Lugli, Paolo
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2017, 64 (03) : 1375 - 1379
  • [50] Highly sensitive and selective detection of the pancreatic cancer biomarker CA 19-9 with the electrolyte-gated MoS2-based field-effect transistor immunosensor
    Rahmani, Hedyeh
    Majd, Samira Mansouri
    Salimi, Abdollah
    IONICS, 2023, 29 (09) : 3769 - 3779