Criticality in the fabrication of ion extraction system for SST-1 neutral beam injector

被引:5
作者
Jana, M. R. [1 ]
Mattoo, S. K. [1 ]
机构
[1] Inst Plasma Res, Gandhinagar 382428, Gujarat, India
关键词
SST-1; neutral beam injector; positive ion source; extraction system; measurements of grid dimensions;
D O I
10.1016/j.fusengdes.2008.02.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
For the heating of plasma in steady-state superconducting tokamak (SST-1) (Y.C. Saxena, SST-1 Team, Present status of the SST-1 project, Nucl. Fusion 40 (2000) 1069-1082; D. Bora, SST-1 Team, Test results on systems developed for the SST-1 tokamak, Nucl. Fusion 43 (2003) 1748-1758), a neutral beam injector is provided to raise the ion temperature to similar to 1 keV. This injector has a capability of injecting hydrogen beam with the power of 0.5 MW at 30 keV. For the upgrade of SST-1, power of 1.7 MW at 55 KeV is required. Further, beam power is to be provided for a pulse length of 1000S. We have designed a neutral beam injector (S.K. Mattoo, A.K. Chakraborty, U.K. Baruah, P.K. Jayakumar, M. Bandyopadhyay, N. Bisai, Ch. Chakrapani, M.R. Jana, R. Onali, V. Prahlad, P.J. Patel, G.B. Patel, B. Prajapati, N.V.M. Rao, S. Rambabu, C. Rotti, S.K. Sharma, S. Shah, V. Sharma, M.J. Singh, Engineering design of the steady-state neutral beam injector for SST-1, Fusion Eng. Des. 56 (2001) 685-691; A.K. Chakraborty, N. Bisai, M.R. Jana, P.K. Jayakumar, U.K. Baruah, P.J. Patel, K. Rajasekar, S.K. Mattoo, Neutral beam injector for steady-state superconducting tokamak, Fusion Technol. (1996) 657-660; P.K. Jayakumar, M.R. Jana, N. Bisai, M. Bajpai, N.P Singh, U.K. Baruah, A.K. Chakraborty, M. Bandyopadhyay, C. Chrakrapani, D. Patel, G.B. Patel, P. Patel, V. Prahlad, N.V.M. Rao, C. Rotti, V. Sreedhar, S.K. Mattoo, Engineering issues of a 1000S neutral beam ion source, Fusion Technol. 1 (1998) 419-422) satisfying the requirements for both SST-1 and its upgrade. Since intense power is to be transported to SST-1 situated at a distance of several meters from the ion source, the optical quality of the beam becomes a primary concern. This in turn, is determined by the uniformity of the ion source plasma and the extractor geometry. To obtain the desired optical quality of the beam, stringent tolerances are to be met during the fabrication of ion extractor system. SST-1 neutral beam injector is based on positive ion source. The extraction system consists of three grids, each having extraction area of (width) 230 mm x (height) 480 mm and 774-shaped apertures of 8-mm diameter. To obtain horizontal focal length of 5.4 m and vertical of 7 m, each grid consists of two halves with 387 apertures. Two halves are inclined at an angle of 1.07+/-0.01 degrees. For long pulse operation, active water cooling is provided by in-laid down of dense network of 22 wavy semicircular (r= 1.1+/-0.05 mm) cooling channels in the space available between the apertures. The required flatness of the copper plate is 100 mu m and positioning tolerance of aperture is +/-60 mu m. The measurement obtained after fabrication is compared with the specifications. It is pointed out that fabrication within set tolerance limit could be achieved only through process of fabrication and high-resolution measurements. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:649 / 654
页数:6
相关论文
共 50 条
  • [1] Design of an ion extractor system for a prototype ion source experiment for SST-1 neutral beam injector
    Jana, M. R.
    Bandyopadhaya, M.
    Singh, N. P.
    Sharma, S. K.
    Chakraborty, A. K.
    Baruah, U. K.
    Mattoo, S. K.
    FUSION ENGINEERING AND DESIGN, 2010, 85 (01) : 122 - 125
  • [2] Engineering design of the steady state neutral beam injector for SST-1
    Mattoo, SK
    Chakraborty, AK
    Baruah, UK
    Jayakumar, PK
    Bandyopadhyay, M
    Bisai, N
    Chakrapani, C
    Jana, MR
    Onali, R
    Prahlad, V
    Patel, PJ
    Patel, GB
    Prajapati, B
    Rao, NVM
    Rambabu, S
    Rotti, C
    Sharma, SK
    Shah, S
    Sharma, V
    Singh, MJ
    Singh, NP
    Sridhar, B
    FUSION ENGINEERING AND DESIGN, 2001, 56-57 : 685 - 691
  • [3] Long pulse characteristics of 5 MW ion source for SST-1 neutral beam injector
    Jana, M. R.
    Mattoo, S. K.
    Chakraborty, A. K.
    Baruah, U. K.
    Patel, G. B.
    Jayakumar, P. K.
    FUSION ENGINEERING AND DESIGN, 2008, 83 (5-6) : 729 - 735
  • [4] Neutral transport baffling studies for SST-1
    Jaishankar, S
    Warrier, M
    Deshpande, SP
    FUSION ENGINEERING AND DESIGN, 2002, 60 (02) : 167 - 178
  • [5] Vacuum system of SST-1 Tokamak
    Khan, Ziauddin
    Pathan, Firozkhan
    George, Siju
    Semwal, Pratibha
    Dhanani, Kalpesh
    Paravastu, Yuvakiran
    Thankey, Prashant
    Ramesh, Gattu
    Himabindu, Manthena
    Pradhan, Subrata
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 692 - 695
  • [6] Fabrication of new joints for SST-1 TF coil winding packs
    Prasad, Upendra
    Sharma, A. N.
    Patel, Dipak
    Doshi, Kalpesh
    Khristi, Yohan
    Varmora, Pankaj
    Chauhan, Pradeep
    Jadeja, S. J.
    Gupta, Pratibha
    Pradhan, S.
    FUSION ENGINEERING AND DESIGN, 2013, 88 (11) : 2945 - 2949
  • [7] Overview of data acquisition system for SST-1 diagnostics
    Sharma, Manika
    Mansuri, Imran
    Raval, Tushar
    Sharma, A. L.
    Pradhan, S.
    FUSION ENGINEERING AND DESIGN, 2016, 112 : 872 - 876
  • [8] Design of a 500 kW CW water load SST-1 tokamak 3.7 GHz for the LHCD system of SST-1 tokamak
    Dixit, Harish V.
    Jain, Yogesh M.
    Jadav, Aviraj R.
    Cheeran, Alice N.
    Gupta, Vikas N.
    Sharma, P. K.
    FUSION ENGINEERING AND DESIGN, 2017, 121 : 32 - 38
  • [9] The Timing System of the Neutral Beam Injector on EAST
    盛鹏
    胡纯栋
    赵远哲
    崔庆龙
    张小丹
    吴德云
    张睿
    林宇莲
    NBI team
    Plasma Science and Technology, 2015, (05) : 425 - 429
  • [10] The Timing System of the Neutral Beam Injector on EAST
    Sheng Peng
    Hu Chundong
    Zhao Yuanzhe
    Cui Qinglong
    Zhang Xiaodan
    Wu Deyun
    Zhang Rui
    Lin Yulian
    PLASMA SCIENCE & TECHNOLOGY, 2015, 17 (05) : 425 - 429