Rapid method for evaluating reversed-phase high-performance liquid chromatography column stability

被引:28
作者
Fonseca, DA
Gutiérrez, HR
Collins, KE
Collins, CH
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
[2] Univ Estadual Campinas, Inst Fis, BR-13084971 Campinas, SP, Brazil
关键词
stationary phases; LC; stability studies;
D O I
10.1016/j.chroma.2003.12.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A procedure is presented for the rapid evaluation of HPLC stationary phase stability at pH 8.4 or 10.1 using a temperature of 60degreesC. Mobile phase (MeOH-0.1 mol 1(-1) aqueous NaHCO3, 50:50, v/v) is continuously passed through the column with periodic injections of a test solution until the several chromatographic parameters of the resulting chromatograms are degraded. The tests were applied to several commercial and laboratory-made stationary phases. After degradation two of these phases, one commercial and one laboratory-made, were examined by elemental analysis and scanning electron microscopy to elucidate the degradation process. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
[31]   Determination of lipophilicity by reversed-phase high-performance liquid chromatography - Influence of 1-octanol in the mobile phase [J].
Liu, XL ;
Tanaka, H ;
Yamauchi, A ;
Testa, B ;
Chuman, H .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1091 (1-2) :51-59
[32]   Development and validation of a reversed-phase high-performance liquid chromatographic method for the quantitation and stability of α-lipoic acid in cosmetic creams [J].
Papageorgiou, S. ;
Varvaresou, A. ;
Panderi, I. ;
Giannakou, M. ;
Spiliopoulou, C. ;
Athanaselis, S. .
INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 2020, 42 (03) :221-228
[33]   Preparation of stationary phases for reversed-phase high-performance liquid chromatography using thermal treatments at high temperature [J].
Vigna, Camila R. M. ;
Bottoli, Carla B. G. ;
Collins, Kenneth E. ;
Collins, Carol H. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1156 (1-2) :60-67
[34]   Use of reversed-phase high-performance liquid chromatography on polystyrene-divinylbenzene columns for the rapid separation and purification of acid-soluble nuclear proteins [J].
Zhelev, NZ ;
Barratt, MJ ;
Mahadevan, LC .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :65-70
[35]   Optimization of chromatographic parameters for the determination of biogenic amines in wines by reversed-phase high-performance liquid chromatography [J].
Romero, R ;
Gázquez, D ;
Bagur, MG ;
Sánchez-Viñas, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 871 (1-2) :75-83
[36]   Reversed-phase liquid chromatography column testing: robustness study of the test [J].
Le Mapihan, K ;
Vial, J ;
Jardy, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) :149-158
[37]   Enhancement of selectivity in reversed-phase liquid chromatography [J].
Lavine, BK ;
Ritter, JP ;
Peterson, S .
JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) :83-90
[38]   Studies of retention and stability of a horizontally polymerized bonded phase for reversed-phase liquid chromatography [J].
Li, L ;
Carr, PW ;
Evans, JF .
JOURNAL OF CHROMATOGRAPHY A, 2000, 868 (02) :153-167
[39]   Column selectivity in reversed-phase liquid chromatography I. A general quantitative relationship [J].
Wilson, NS ;
Nelson, MD ;
Dolan, JW ;
Snyder, LR ;
Wolcott, RG ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (02) :171-193
[40]   Retention characteristics of an immobilized artificial. membrane column in reversed-phase liquid chromatography [J].
Lepont, C ;
Poole, CF .
JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) :107-124