A procedure is presented for the rapid evaluation of HPLC stationary phase stability at pH 8.4 or 10.1 using a temperature of 60degreesC. Mobile phase (MeOH-0.1 mol 1(-1) aqueous NaHCO3, 50:50, v/v) is continuously passed through the column with periodic injections of a test solution until the several chromatographic parameters of the resulting chromatograms are degraded. The tests were applied to several commercial and laboratory-made stationary phases. After degradation two of these phases, one commercial and one laboratory-made, were examined by elemental analysis and scanning electron microscopy to elucidate the degradation process. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
[21]   Sensitive determination of melatonin by precolumn derivatization and reversed-phase high-performance liquid chromatography [J].
Iinuma, F ;
Hamase, K ;
Matsubayashi, S ;
Takahashi, M ;
Watanabe, M ;
Zaitsu, K .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :67-72
[22]   High-performance liquid chromatography of basic compounds - Problems, possible solutions and tests of reversed-phase columns [J].
McCalley, DV ;
Brereton, RG .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :407-420
[23]   Use of alumina with anchored polymer coating as packing material for reversed-phase high-performance liquid chromatography [J].
Mao, Y ;
Fung, BM .
JOURNAL OF CHROMATOGRAPHY A, 1997, 790 (1-2) :9-15
[24]   Stability of silica-based, endcapped columns with pH 7 and 11 mobile phases for reversed-phase high-performance liquid chromatography [J].
Kirkland, JJ ;
Henderson, JW ;
DeStefano, JJ ;
vanStraten, MA ;
Claessens, HA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :97-112
[25]   Sensitive determination of alkoxyethanols by pre-column derivatization with 1-anthroylnitrile and reversed-phase high-performance liquid chromatography [J].
Yoshikawa, M ;
Tani, C .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) :215-221
[26]   Reversed-phase high-performance liquid chromatography of basic compounds at pH11 with silica-based column packings [J].
Kirkland, JJ ;
van Straten, MA ;
Claessens, HA .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :111-120
[27]   Influence of sample mass on the performance of reversed-phase columns in the analysis of strongly basic compounds by high-performance liquid chromatography [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (01) :31-46
[28]   Separation of primary and secondary amines as their sulfonamide derivatives by reversed-phase high-performance liquid chromatography [J].
Saleh, MI ;
Pok, FW .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :173-178
[29]   Native and modified alumina, titania and zirconia in normal and reversed-phase high-performance liquid chromatography [J].
Kurganov, A ;
Trudinger, U ;
Isaeva, T ;
Unger, K .
CHROMATOGRAPHIA, 1996, 42 (3-4) :217-222
[30]   Feasibility of using gravimetry to measure excess adsorption effects of a binary solvent system in a reversed-phase high-performance liquid chromatography column [J].
Loeser, Eric ;
Babiak, Stanislaw ;
Liu, Zhaoxia ;
Girgis, Michael ;
Drumm, Patrick .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) :3927-3932