Development of x-ray microcalorimeter imaging spectrometers for the X-ray Surveyor mission concept

被引:5
|
作者
Bandler, Simon R. [1 ]
Adams, Joseph S. [1 ,2 ,3 ]
Chervenak, James A. [1 ]
Datesman, Aaron M. [1 ,10 ]
Eckart, Megan E. [1 ]
Finkbeiner, Fred M. [1 ,9 ]
Kelley, Richard L. [1 ]
Kilbourne, Caroline A. [1 ]
Betancourt-Martineza, Gabriel [1 ,4 ,5 ]
Miniussi, Antoine R. [1 ,6 ,7 ]
Porter, Frederick S. [1 ]
Sadleir, John E. [1 ]
Sakai, Kazuhiro [1 ,6 ,7 ]
Smith, Stephen J. [1 ,2 ,3 ]
Stevenson, Thomas R. [1 ]
Wakeham, Nicholas A. [1 ,8 ]
Wassell, Edward J. [1 ,10 ]
Yoon, Wonsik [1 ,8 ]
Becker, Dan [11 ]
Bennett, Douglas [11 ]
Doriese, Wilham B. [11 ]
Fowler, Joseph W. [11 ]
Gard, Johnathon D. [11 ,12 ]
Hilton, Gene C. [11 ]
Mates, Benjamin [11 ,12 ]
Morgan, Kelsey M. [11 ]
Reintsema, Carl D. [11 ]
Swetz, Daniel [11 ]
Ullom, Joel N. [11 ,12 ]
Chaudhuri, Saptarshi [13 ]
Irwin, Kent D. [13 ]
Lee, Sang-Jun [13 ]
Vikhlinin, Alexey [14 ]
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[2] CRESST, Baltimore, MD 21250 USA
[3] Univ Maryland Baltimore Cty, Baltimore, MD 21250 USA
[4] CRESST, College Pk, MD 20742 USA
[5] Univ Maryland Coll Pk, College Pk, MD 20742 USA
[6] CRESST, Greenbelt, MD 20771 USA
[7] Univ Space Res Assoc, Greenbelt, MD 20771 USA
[8] Univ Space Res Assoc, NASA Postdoctoral Program, Greenbelt, MD 20771 USA
[9] Wyle Informat Syst Inc, Mclean, VA 22102 USA
[10] Stinger Ghaffarian Technol, Greenbelt, MD 20771 USA
[11] Natl Inst Stand & Technol, Boulder, CO 80305 USA
[12] Univ Colorado, Boulder, CO 80309 USA
[13] Stanford Univ, Palo Alto, CA 94305 USA
[14] Smithsonian Astrophys Observ, Cambridge, MA 02912 USA
关键词
X-ray Surveyor; microcalorimeter; hydra; multiplexing; MULTIPLEXER; DETECTORS;
D O I
10.1117/12.2232156
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Four astrophysics missions are currently being studied by NASA as candidate large missions to be chosen in the 2020 astrophysics decadal survey.(1) One of these missions is the "X-Ray Surveyor" (XRS), and possible configurations of this mission are currently under study by a science and technology definition team (STDT). One of the key instruments under study is an X-ray microcalorimeter, and the requirements for such an instrument are currently under discussion. In this paper we review some different detector options that exist for this instrument, and discuss what array formats might be possible. We have developed one design option that utilizes either transition-edge sensor (TES) or magnetically coupled calorimeters (MCC) in pixel array-sizes approaching 100 kilo-pixels. To reduce the number of sensors read out to a plausible scale, we have assumed detector geometries in which a thermal sensor such a TES or MCC can read out a sub-array of 20-25 individual 1" pixels. In this paper we describe the development status of these detectors, and also discuss the different options that exist for reading out the very large number of pixels.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] The microcalorimeter X-ray detector: A true paradigm shift in X-ray spectroscopy
    T. Jach
    J. N. Ullom
    W. T. Elam
    The European Physical Journal Special Topics, 2009, 169 : 237 - 242
  • [33] X-RAY SPECTROMETERS FOR PIXE
    CAMPBELL, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 115 - 125
  • [34] SEMICONDUCTOR X-RAY SPECTROMETERS
    CAMERON, JF
    RIDLEY, JD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (01) : 363 - &
  • [35] Precision x-ray spectrometers
    Hudson, JC
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA AND REVIEW OF SCIENTIFIC INSTRUMENTS, 1924, 9 (03): : 259 - 301
  • [36] SEMICONDUCTOR X-RAY SPECTROMETERS
    MUGGLETON, AH
    NUCLEAR INSTRUMENTS & METHODS, 1972, 101 (01): : 113 - +
  • [37] Development of the X-ray microcalorimeter with a superconductive Iridium layer
    Ohno, M
    Noguchi, Y
    Fukuda, D
    Takahashi, H
    Nakazawa, M
    Ataka, M
    Ukibe, M
    Hirayama, F
    Ohkubo, M
    Shimizu, HM
    LOW TEMPERATURE DETECTORS, 2002, 605 : 259 - 262
  • [38] Constellation X-ray mission - Recent developments for mission concept and technology development
    Tananbaum, H
    White, N
    Bookbinder, J
    Petre, R
    Weaver, K
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 492 - 504
  • [39] X-ray imaging spectrometers for Astro-E: Ground calibration in soft X-ray range
    Hayashida, K
    Kitamoto, S
    Miyata, E
    Tsunemi, H
    Yoshita, E
    Kohmura, T
    Mori, K
    Katayama, K
    Katayama, H
    Shouho, M
    Ohta, M
    Dotani, T
    Ozaki, M
    Koyama, K
    Awaki, H
    Tsuru, TG
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 123 - 136
  • [40] Beyond Chandra - the X-ray Surveyor
    Weisskopf, Martin C.
    Gaskin, Jessica
    Tananbaum, Harvey
    Vikhlinin, Alexey
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE IV, 2015, 9510