Heat exchanger; Passive heat transfer; Swirl flow devices; Turbulators; Friction Factor; Nusselt number; Heat transfer performance; FRICTION FACTOR CHARACTERISTICS; COILED WIRE INSERTS; THERMAL PERFORMANCE-CHARACTERISTICS; TWISTED-TAPE; TURBULENT-FLOW; CIRCULAR TUBE; TRANSFER AUGMENTATION; NATURAL-CONVECTION; PRESSURE-DROP; CORRUGATED TUBES;
D O I
10.1016/j.rser.2015.04.113
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Economic reasons (material and energy saving) leads to make efforts for making more efficient heat exchange. The heat transfer enhancement techniques are widely used in many applications in the heating process to make possible reduction in weight and size or enhance the performance of heat exchangers. These techniques are classified as active and passive techniques. The active technique required external power while the passive technique does not need any external power. The passive techniques are valuable compared with the active techniques because the swirl inserts manufacturing process is simple and can be easily employed in an existing heat exchanger. Insertion of swirl flow devices enhance the convective heat transfer by making swirl into the bulk flow and disrupting the boundary layer at the tube surface due to repeated changes in the surface geometry. An effort has been made in this paper to carry out an extensive literature review of various turbulators (coiled tubes, extended surfaces (fin, louvered strip, winglet), rough surfaces (Corrugated tube, Rib) and swirl flow devices such as twisted tape, conical ring, snail entry turbulator, vortex rings, coiled wire) for enhancing heat transfer in heat exchangers. It can be concluded that wire coil gives better overall performance if the pressure drop penalty is considered. The use of coiled square wire turbulators leads to a considerable increase in heat transfer and friction loss over those of a smooth wall tube. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:444 / 469
页数:26
相关论文
共 117 条
[1]   Heat transfer augmentation by coiled wire inserts during forced convection condensation of R-22 inside horizontal tubes [J].
Agrawal, KN ;
Kumar, A ;
Behabadi, MAA ;
Varma, HK .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1998, 24 (04) :635-650
[2]   A comparison of heat transfer enhancement in a medium temperature thermal energy storage heat exchanger using fins [J].
Agyenim, Francis ;
Eames, Philip ;
Smyth, Mervyn .
SOLAR ENERGY, 2009, 83 (09) :1509-1520
[4]   Pressure drop and heat transfer augmentation due to coiled wire inserts during laminar flow of oil inside a horizontal tube [J].
Akhavan-Behabadi, M. A. ;
Kumar, Ravi ;
Salimpour, M. R. ;
Azimi, R. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (02) :373-379
[5]   Evaluation of heat transfer and exergy loss in a concentric double pipe exchanger equipped with helical wires [J].
Akpinar, Ebru Kavak .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (18-19) :3473-3486
[6]   Numerical study on turbulent heat transfer and pressure drop of nanofluid in coiled tube-in-tube heat exchangers [J].
Aly, Wael I. A. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 79 :304-316
[7]  
[Anonymous], 2006, P 2 JOINT INT C SUST
[8]   Performance assessment in a heat exchanger tube fitted with double counter twisted tape inserts [J].
Bhuiya, M. M. K. ;
Sayem, A. S. M. ;
Islam, M. ;
Chowdhury, M. S. U. ;
Shahabuddin, M. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2014, 50 :25-33
[9]   Thermal characteristics in a heat exchanger tube fitted with triple twisted tape inserts [J].
Bhuiya, M. M. K. ;
Chowdhury, M. S. U. ;
Shahabuddin, M. ;
Saha, M. ;
Memon, L. A. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 48 :124-132
[10]   Convective heat transfer in a channel with perforated ribs [J].
Buchlin, JM .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (04) :332-340