Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study

被引:26
作者
Chevance, Virgile [1 ]
Damy, Thibaud [2 ,3 ,4 ,5 ]
Tacher, Vania [1 ,3 ]
Legou, Francois [1 ]
Ridouani, Fourat [1 ]
Luciani, Alain [1 ,6 ]
Kobeiter, Hicham [1 ,3 ]
Rahmouni, Alain [1 ,6 ]
Deux, Jean-Francois [1 ,3 ,4 ,5 ]
机构
[1] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Imagerie Med, F-94000 Creteil, France
[2] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Cardiol, F-94000 Creteil, France
[3] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ ATVB Ageing Thorax Vessels Blo, F-94000 Creteil, France
[4] Univ Paris Est Creteil UPEC, GRC Amyloid Res Inst, F-94000 Creteil, France
[5] Univ Paris Est Creteil UPEC, Reseau Amylose Mondor Grp Hosp Henri Mondor Alber, F-94000 Creteil, France
[6] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ VIC Virus Immun Canc, F-94000 Creteil, France
关键词
Amyloidosis/diagnosis; Amyloidosis/complication; Dual-energy computed tomography; Cardiac imaging techniques; Iodine map; EXTRACELLULAR VOLUME FRACTION; CARDIOVASCULAR MAGNETIC-RESONANCE; LIGHT-CHAIN AMYLOIDOSIS; TRANSTHYRETIN AMYLOIDOSIS; NONINVASIVE DETECTION; CT; CARDIOMYOPATHY; QUANTIFICATION; PROGNOSIS; FIBROSIS;
D O I
10.1007/s00330-017-4984-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. IVS thickness was significantly (p < 0.001) higher in CA (17 +/- 4 mm) and CH (15 +/- 3 mm) patients than in control patients (10 +/- 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 +/- 0.12) and ECV (0.56 +/- 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 +/- 0.07 and 0.36 +/- 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 +/- 0.07 and 0.35 +/- 0.04, respectively). CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters.
引用
收藏
页码:816 / 823
页数:8
相关论文
共 50 条
  • [41] Dual-Energy Computed Tomography Iodine Maps: Application in the Diagnosis of Periprosthetic Joint Infection in Total Hip Arthroplasty
    Cheng, Qiang
    Yang, Yaji
    Li, Feilong
    Li, Xiaobin
    Qin, Leilei
    Huang, Wei
    JOURNAL OF ARTHROPLASTY, 2025, 40 (02) : 499 - 505
  • [42] The application of dual-energy computed tomography in the diagnosis of acute gouty arthritis
    Huaxiang Wu
    Jing Xue
    Lu Ye
    Qijing Zhou
    Dan Shi
    Rongzhen Xu
    Clinical Rheumatology, 2014, 33 : 975 - 979
  • [43] Cardiac myocardial perfusion imaging using dual source computed tomography
    Blankstein, Ron
    Okada, David R.
    Rocha-Filho, Jose A.
    Rybicki, Frank J.
    Brady, Thomas J.
    Cury, Ricardo C.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 209 - 216
  • [44] What is the diagnostic value of dual-energy computed tomography in patients with clinical diagnosis of gout?
    Lee, Jung Sun
    Seo, Wook Jang
    ADVANCES IN RHEUMATOLOGY, 2021, 61 (01)
  • [45] Correlation of Quantitative Dual-Energy Computed Tomography Iodine Maps and Abdominal Computed Tomography Perfusion Measurements Are Single-Acquisition Dual-Energy Computed Tomography Iodine Maps More Than a Reduced-Dose Surrogate of Conventional Computed Tomography Perfusion?
    Stiller, Wolfram
    Skornitzke, Stephan
    Fritz, Franziska
    Klauss, Miriam
    Hansen, Jens
    Pahn, Gregor
    Grenacher, Lars
    Kauczor, Hans-Ulrich
    INVESTIGATIVE RADIOLOGY, 2015, 50 (10) : 703 - 708
  • [46] Added value of iodine-specific imaging and virtual non-contrast imaging for gastrointestinal assessment using dual-energy computed tomography
    Kocher, Madison R.
    Kovacs, Mark D.
    Stewart, William
    Flemming, Brian P.
    Hinen, Shaun
    Hardie, Andrew D.
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2021, 11 : 1 - 8
  • [47] Evaluation of Vascular Parameters in Patients With Pulmonary Thromboembolic Disease Using Dual-energy Computed Tomography
    Nallasamy, Navi
    Bullen, Jennifer
    Karim, Wadih
    Heresi, Gustavo A.
    Renapurkar, Rahul D.
    JOURNAL OF THORACIC IMAGING, 2019, 34 (06) : 367 - 372
  • [48] Dual-energy computed tomography-based iodine concentration as a predictor of histopathological response to preoperative chemoradiotherapy for pancreatic cancer
    Ohira, Shingo
    Ikawa, Toshiki
    Kanayama, Naoyuki
    Minamitani, Masanari
    Kihara, Sayaka
    Inui, Shoki
    Ueda, Yoshihiro
    Miyazaki, Masayoshi
    Yamashita, Hideomi
    Nishio, Teiji
    Koizumi, Masahiko
    Nakagawa, Keiichi
    Konishi, Koji
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (06) : 940 - 947
  • [49] Prognostic Impact of Myocardial Extracellular Volume Fraction Assessment Using Dual-Energy Computed Tomography in Patients Treated With Aortic Valve Replacement for Severe Aortic Stenosis
    Suzuki, Masataka
    Toba, Takayoshi
    Izawa, Yu
    Fujita, Hiroshi
    Miwa, Keisuke
    Takahashi, Yu
    Toh, Hiroyuki
    Kawamori, Hiroyuki
    Otake, Hiromasa
    Tanaka, Hidekazu
    Fujiwara, Sei
    Watanabe, Yoshiaki
    Kono, Atsushi K.
    Okada, Kenji
    Hirata, Ken-Ichi
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (18):
  • [50] Measurement of myocardial extracellular volume fraction in patients with heart failure with preserved ejection fraction using dual-energy computed tomography
    Qi, Rong-Xing
    Jiang, Jia-Shen
    Shao, Jun
    Zhang, Qing
    Zheng, Kou-Long
    Xiao, Jing
    Huang, Sheng
    Gong, Shen-Chu
    EUROPEAN RADIOLOGY, 2022, 32 (06) : 4253 - 4263