共 50 条
Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
被引:26
作者:
Chevance, Virgile
[1
]
Damy, Thibaud
[2
,3
,4
,5
]
Tacher, Vania
[1
,3
]
Legou, Francois
[1
]
Ridouani, Fourat
[1
]
Luciani, Alain
[1
,6
]
Kobeiter, Hicham
[1
,3
]
Rahmouni, Alain
[1
,6
]
Deux, Jean-Francois
[1
,3
,4
,5
]
机构:
[1] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Imagerie Med, F-94000 Creteil, France
[2] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Cardiol, F-94000 Creteil, France
[3] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ ATVB Ageing Thorax Vessels Blo, F-94000 Creteil, France
[4] Univ Paris Est Creteil UPEC, GRC Amyloid Res Inst, F-94000 Creteil, France
[5] Univ Paris Est Creteil UPEC, Reseau Amylose Mondor Grp Hosp Henri Mondor Alber, F-94000 Creteil, France
[6] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ VIC Virus Immun Canc, F-94000 Creteil, France
关键词:
Amyloidosis/diagnosis;
Amyloidosis/complication;
Dual-energy computed tomography;
Cardiac imaging techniques;
Iodine map;
EXTRACELLULAR VOLUME FRACTION;
CARDIOVASCULAR MAGNETIC-RESONANCE;
LIGHT-CHAIN AMYLOIDOSIS;
TRANSTHYRETIN AMYLOIDOSIS;
NONINVASIVE DETECTION;
CT;
CARDIOMYOPATHY;
QUANTIFICATION;
PROGNOSIS;
FIBROSIS;
D O I:
10.1007/s00330-017-4984-8
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. IVS thickness was significantly (p < 0.001) higher in CA (17 +/- 4 mm) and CH (15 +/- 3 mm) patients than in control patients (10 +/- 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 +/- 0.12) and ECV (0.56 +/- 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 +/- 0.07 and 0.36 +/- 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 +/- 0.07 and 0.35 +/- 0.04, respectively). CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters.
引用
收藏
页码:816 / 823
页数:8
相关论文
共 50 条