Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study

被引:26
作者
Chevance, Virgile [1 ]
Damy, Thibaud [2 ,3 ,4 ,5 ]
Tacher, Vania [1 ,3 ]
Legou, Francois [1 ]
Ridouani, Fourat [1 ]
Luciani, Alain [1 ,6 ]
Kobeiter, Hicham [1 ,3 ]
Rahmouni, Alain [1 ,6 ]
Deux, Jean-Francois [1 ,3 ,4 ,5 ]
机构
[1] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Imagerie Med, F-94000 Creteil, France
[2] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Cardiol, F-94000 Creteil, France
[3] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ ATVB Ageing Thorax Vessels Blo, F-94000 Creteil, France
[4] Univ Paris Est Creteil UPEC, GRC Amyloid Res Inst, F-94000 Creteil, France
[5] Univ Paris Est Creteil UPEC, Reseau Amylose Mondor Grp Hosp Henri Mondor Alber, F-94000 Creteil, France
[6] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ VIC Virus Immun Canc, F-94000 Creteil, France
关键词
Amyloidosis/diagnosis; Amyloidosis/complication; Dual-energy computed tomography; Cardiac imaging techniques; Iodine map; EXTRACELLULAR VOLUME FRACTION; CARDIOVASCULAR MAGNETIC-RESONANCE; LIGHT-CHAIN AMYLOIDOSIS; TRANSTHYRETIN AMYLOIDOSIS; NONINVASIVE DETECTION; CT; CARDIOMYOPATHY; QUANTIFICATION; PROGNOSIS; FIBROSIS;
D O I
10.1007/s00330-017-4984-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. IVS thickness was significantly (p < 0.001) higher in CA (17 +/- 4 mm) and CH (15 +/- 3 mm) patients than in control patients (10 +/- 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 +/- 0.12) and ECV (0.56 +/- 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 +/- 0.07 and 0.36 +/- 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 +/- 0.07 and 0.35 +/- 0.04, respectively). CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters.
引用
收藏
页码:816 / 823
页数:8
相关论文
共 50 条
  • [31] Role of Dual-Energy Computed Tomography Scan in Diagnosis of Gout
    Almeshal, Nawaf
    Kaw, Dinkar
    Iwuagwu, Cletus
    Altorok, Nezam
    JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2014, 20 (08) : 447 - 447
  • [32] Potential for intramyocardial fibrosis detection based on estimation of extracellular volume using dual-energy computed tomography
    Mershina, E. A.
    Filatova, D. A.
    Lisitskaya, M., V
    Ryzhkova, E., V
    Myasnikov, R. P.
    Sinitsyn, V. E.
    RATIONAL PHARMACOTHERAPY IN CARDIOLOGY, 2023, 19 (06) : 565 - 571
  • [33] Stratification of Pulmonary Nodules Using Quantitative Iodine Maps from Dual-Energy Computed Tomography
    Hokamp, Nils Grosse
    Gupta, Amit
    Gilkeson, Robert C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199 (02) : E3 - E4
  • [34] Accuracy of spectral curves at different phantom sizes and iodine concentrations using dual-source dual-energy computed tomography
    Sato, Kazuhiro
    Kageyama, Ryota
    Sawatani, Yuta
    Takano, Hirokazu
    Kayano, Shingo
    Takane, Yumi
    Saito, Haruo
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (01) : 103 - 116
  • [35] Computed tomography numbers obtained for varying iodine contrast concentrations by different-generation dual-energy computed tomography scanners
    Tsukamoto, Tomokatsu
    Masuda, Takanori
    Takahata, Takashi
    Kawamoto, Yoshinori
    Uenaka, Osamu
    Mori, Hiroki
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (14) : 1358 - 1364
  • [36] Computation of Calcium Score With Dual-Energy Computed Tomography: A Phantom Study
    Kumar, Vidhya
    Min, James K.
    He, Xin
    Raman, Subha V.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (01) : 156 - 158
  • [37] The Clinical Utility of Dual-Energy Computed Tomography in the Diagnosis of Gout-A Cross-Sectional Study
    Sotniczuk, Maria
    Nowakowska-Plaza, Anna
    Wronski, Jakub
    Wislowska, Malgorzata
    Sudol-Szopinska, Iwona
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)
  • [38] Dual-energy computed tomography vs ultrasound, alone or combined, for the diagnosis of gout: a prospective study of accuracy
    Singh, Jasvinder A.
    Budzik, Jean-Francois
    Becce, Fabio
    Pascart, Tristan
    RHEUMATOLOGY, 2021, 60 (10) : 4861 - 4867
  • [39] Optimal Contrast of Computed Tomography Portal Venography Using Dual-Energy Computed Tomography
    Wang, Qi
    Shi, Gaofeng
    Liu, Xiang
    Wu, Runze
    Wang, Shijie
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (02) : 142 - 148
  • [40] Quantitative evaluation of non-ischemic dilated cardiomyopathy by late iodine enhancement using rapid kV switching dual-energy computed tomography: A feasibility study
    Ohta, Yasutoshi
    Kitao, Shinichiro
    Yunaga, Hiroto
    Watanabe, Tomomi
    Mukai-Yatagai, Natsuko
    Kishimoto, Junichi
    Yamamoto, Kazuhiro
    Ogawa, Toshihide
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (02) : 148 - 156