Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study

被引:26
|
作者
Chevance, Virgile [1 ]
Damy, Thibaud [2 ,3 ,4 ,5 ]
Tacher, Vania [1 ,3 ]
Legou, Francois [1 ]
Ridouani, Fourat [1 ]
Luciani, Alain [1 ,6 ]
Kobeiter, Hicham [1 ,3 ]
Rahmouni, Alain [1 ,6 ]
Deux, Jean-Francois [1 ,3 ,4 ,5 ]
机构
[1] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Imagerie Med, F-94000 Creteil, France
[2] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Cardiol, F-94000 Creteil, France
[3] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ ATVB Ageing Thorax Vessels Blo, F-94000 Creteil, France
[4] Univ Paris Est Creteil UPEC, GRC Amyloid Res Inst, F-94000 Creteil, France
[5] Univ Paris Est Creteil UPEC, Reseau Amylose Mondor Grp Hosp Henri Mondor Alber, F-94000 Creteil, France
[6] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ VIC Virus Immun Canc, F-94000 Creteil, France
关键词
Amyloidosis/diagnosis; Amyloidosis/complication; Dual-energy computed tomography; Cardiac imaging techniques; Iodine map; EXTRACELLULAR VOLUME FRACTION; CARDIOVASCULAR MAGNETIC-RESONANCE; LIGHT-CHAIN AMYLOIDOSIS; TRANSTHYRETIN AMYLOIDOSIS; NONINVASIVE DETECTION; CT; CARDIOMYOPATHY; QUANTIFICATION; PROGNOSIS; FIBROSIS;
D O I
10.1007/s00330-017-4984-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. IVS thickness was significantly (p < 0.001) higher in CA (17 +/- 4 mm) and CH (15 +/- 3 mm) patients than in control patients (10 +/- 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 +/- 0.12) and ECV (0.56 +/- 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 +/- 0.07 and 0.36 +/- 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 +/- 0.07 and 0.35 +/- 0.04, respectively). CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters.
引用
收藏
页码:816 / 823
页数:8
相关论文
共 50 条
  • [21] Estimation of renal function using iodine maps in dual-energy spectral computed tomography urography: a feasibility and accuracy study
    Shigeng Wang
    Xiaoyu Tong
    Jingyi Zhang
    Yong Fan
    Wei Wei
    Jianying Li
    Yijun Liu
    Mengting Hu
    Qiye Chen
    Lei Liu
    Abdominal Radiology, 2024, 49 : 997 - 1005
  • [22] Pilot Study: Evaluation of Dual-Energy Computed Tomography Measurement Strategies for Positron Emission Tomography Correlation in Pancreatic Adenocarcinoma
    Oldan, Jorge
    He, Miao
    Wu, Teresa
    Silva, Alvin C.
    Li, Jing
    Mitchell, J. Ross
    Pavlicek, William M.
    Roarke, Michael C.
    Hara, Amy K.
    JOURNAL OF DIGITAL IMAGING, 2014, 27 (06) : 824 - 832
  • [23] Study of the Natural Crystalline Lens Characteristics Using Dual-Energy Computed Tomography
    Sachs, Jeffrey R.
    Nahmias, Javier A.
    Hiatt, Kevin D.
    Bomar, James G.
    West, Thomas G.
    Bunch, Paul M.
    Benayoun, Marc D.
    Lack, Chris
    Thompson, Atalie C.
    DIAGNOSTICS, 2022, 12 (11)
  • [24] The application of dual-energy computed tomography in the diagnosis of acute gouty arthritis
    Wu, Huaxiang
    Xue, Jing
    Ye, Lu
    Zhou, Qijing
    Shi, Dan
    Xu, Rongzhen
    CLINICAL RHEUMATOLOGY, 2014, 33 (07) : 975 - 979
  • [25] Organ dose in cardiac dual-energy computed tomography: a Monte Carlo study
    Delaram Pakravan
    Farshid Babapour Mofrad
    Mohammad Reza Deevband
    Mahdi Ghorbani
    Hamidreza Pouraliakbar
    Physical and Engineering Sciences in Medicine, 2022, 45 : 157 - 166
  • [26] Organ dose in cardiac dual-energy computed tomography: a Monte Carlo study
    Pakravan, Delaram
    Mofrad, Farshid Babapour
    Deevband, Mohammad Reza
    Ghorbani, Mahdi
    Pouraliakbar, Hamidreza
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (01) : 157 - 166
  • [27] Evaluation of monoenergetic late iodine enhancement dual-energy computed tomography for imaging of chronic myocardial infarction
    Wichmann, Julian L.
    Arbaciauskaite, Ruta
    Kerl, J. Matthias
    Frellesen, Claudia
    Bodelle, Boris
    Lehnert, Thomas
    Monsefi, Nadejda
    Vogl, Thomas J.
    Bauer, Ralf W.
    EUROPEAN RADIOLOGY, 2014, 24 (06) : 1211 - 1218
  • [28] Amiodarone-induced hepatotoxicity - quantitative measurement of iodine density in the liver using dual-energy computed tomography: Three case reports
    Lv, Hai-Juan
    Zhao, Hong-Wei
    WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (20) : 4958 - 4965
  • [29] Dual-energy Computed Tomography for the Diagnosis of Acute Gouty Arthritis
    Huang, Zengfa
    Li, Zuoqin
    Xiao, Jianwei
    Xie, Yuanliang
    Hu, Yun
    Zhang, Shutong
    Wang, Xiang
    CURRENT MEDICAL IMAGING, 2022, 18 (03) : 305 - 311
  • [30] Dual-energy computed tomography compared with ultrasound in the diagnosis of gout
    Gruber, Michael
    Bodner, Gerd
    Rath, Eva
    Supp, Gabriela
    Weber, Michael
    Schueller-Weidekamm, Claudia
    RHEUMATOLOGY, 2014, 53 (01) : 173 - 179