Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study

被引:26
|
作者
Chevance, Virgile [1 ]
Damy, Thibaud [2 ,3 ,4 ,5 ]
Tacher, Vania [1 ,3 ]
Legou, Francois [1 ]
Ridouani, Fourat [1 ]
Luciani, Alain [1 ,6 ]
Kobeiter, Hicham [1 ,3 ]
Rahmouni, Alain [1 ,6 ]
Deux, Jean-Francois [1 ,3 ,4 ,5 ]
机构
[1] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Imagerie Med, F-94000 Creteil, France
[2] Grp Hosp Henri Mondor Albert Chenevier, AP HP, Serv Cardiol, F-94000 Creteil, France
[3] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ ATVB Ageing Thorax Vessels Blo, F-94000 Creteil, France
[4] Univ Paris Est Creteil UPEC, GRC Amyloid Res Inst, F-94000 Creteil, France
[5] Univ Paris Est Creteil UPEC, Reseau Amylose Mondor Grp Hosp Henri Mondor Alber, F-94000 Creteil, France
[6] Univ Paris Est Creteil, IMRB Inst Mondor Rech Biomed, DHU Dept Hosp Univ VIC Virus Immun Canc, F-94000 Creteil, France
关键词
Amyloidosis/diagnosis; Amyloidosis/complication; Dual-energy computed tomography; Cardiac imaging techniques; Iodine map; EXTRACELLULAR VOLUME FRACTION; CARDIOVASCULAR MAGNETIC-RESONANCE; LIGHT-CHAIN AMYLOIDOSIS; TRANSTHYRETIN AMYLOIDOSIS; NONINVASIVE DETECTION; CT; CARDIOMYOPATHY; QUANTIFICATION; PROGNOSIS; FIBROSIS;
D O I
10.1007/s00330-017-4984-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. IVS thickness was significantly (p < 0.001) higher in CA (17 +/- 4 mm) and CH (15 +/- 3 mm) patients than in control patients (10 +/- 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 +/- 0.12) and ECV (0.56 +/- 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 +/- 0.07 and 0.36 +/- 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 +/- 0.07 and 0.35 +/- 0.04, respectively). CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters.
引用
收藏
页码:816 / 823
页数:8
相关论文
共 50 条
  • [1] Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
    Virgile Chevance
    Thibaud Damy
    Vania Tacher
    François Legou
    Fourat Ridouani
    Alain Luciani
    Hicham Kobeiter
    Alain Rahmouni
    Jean-François Deux
    European Radiology, 2018, 28 : 816 - 823
  • [2] Measurement of myocardial extracellular volume using cardiac dual-energy computed tomography in patients with ischaemic cardiomyopathy: a comparison of different methods
    Shao, Jun
    Jiang, Jia-Shen
    Wang, Xiao-Yu
    Wu, Su-Meng
    Xiao, Jing
    Zheng, Kou-Long
    Qi, Rong-Xing
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (07): : 1591 - 1600
  • [3] Accuracy of dual-energy computed tomography for the measurement of iodine concentration using cardiac CT protocols: validation in a phantom model
    James D. Koonce
    Rozemarijn Vliegenthart
    U. Joseph Schoepf
    Bernhard Schmidt
    Amy E. Wahlquist
    Paul J. Nietert
    Gorka Bastarrika
    Thomas G. Flohr
    Felix G. Meinel
    European Radiology, 2014, 24 : 512 - 518
  • [4] Accuracy of dual-energy computed tomography for the measurement of iodine concentration using cardiac CT protocols: validation in a phantom model
    Koonce, James D.
    Vliegenthart, Rozemarijn
    Schoepf, U. Joseph
    Schmidt, Bernhard
    Wahlquist, Amy E.
    Nietert, Paul J.
    Bastarrika, Gorka
    Flohr, Thomas G.
    Meinel, Felix G.
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 512 - 518
  • [5] Reproducibility of myocardial extracellular volume quantification using dual-energy computed tomography in patients with cardiac amyloidosis
    Kadoya, Yoshito
    Omaygenc, Mehmet Onur
    Chow, Benjamin
    Small, Gary R.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2025, 19 (01) : 74 - 80
  • [6] Measurement of Myocardial Extracellular Volume Fraction FromIodine Density Images Using Single-Source, Dual-Energy Computed Tomography: A Feasibility Study
    Ohta, Yasutoshi
    Kitao, Shinichiro
    Watanabe, Tomomi
    Mukai, Natsuko
    Kishimoto, Junichi
    Yamamoto, Kazuhiro
    Ogawa, Toshihide
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (05) : 750 - 756
  • [7] Late iodine enhancement and myocardial extracellular volume quantification in cardiac amyloidosis by using dual-energy cardiac computed tomography performed on a dual-layer spectral detector scanner
    Oda, Seitaro
    Nakaura, Takeshi
    Utsunomiya, Daisuke
    Hirakawa, Kyoko
    Takashio, Seiji
    Izumiya, Yasuhiro
    Tsujita, Kenichi
    Hata, Hiroyuki
    Ando, Yukio
    Yamashita, Yasuyuki
    AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2018, 25 (02): : 137 - 138
  • [8] Dual-Energy Computed Tomography in Cardiac Imaging
    Boettcher, Benjamin
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Schoepf, Uwe Joseph
    Meinel, Felix G.
    van Assen, Marly
    De Cecco, Carlo N.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 995 - 1009
  • [9] Cardiac Applications of Dual-Energy Computed Tomography
    Lempel, Matthew
    Frishman, William H.
    CARDIOLOGY IN REVIEW, 2019, 27 (04) : 208 - 210
  • [10] Iodine Quantification Using Dual-Energy Computed Tomography for Differentiating Thymic Tumors
    Yan, Wei-Qiang
    Xin, Yong-Kang
    Jing, Yong
    Li, Gang-Feng
    Wang, Shu-Mei
    Rong, Wei-Cheng
    Xiao, Gang
    Lei, Xue-Bin
    Li, Bo
    Hu, Yu-Chuan
    Cui, Guang-Bin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 873 - 880