Digital measurement of radiographic tibial plateau angle. A comparison to measurement on printed digital images

被引:17
|
作者
Lister, S. A. [1 ]
Roush, J. K. [1 ]
Renberg, W. C. [1 ]
机构
[1] Kansas State Univ, Coll Vet Med, Dept Small Anim Surg, Manhattan, KS 66506 USA
关键词
TPA; TPLO; digital measurement; canine;
D O I
10.3415/VCOT-07-05-0046
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Pre-operative digital radiographs from 50 dogs undergoing a tibial plateau leveling osteotomy were evaluated. Tibial plateau angles were measured directly on printed films and measured on digital images using two different commercial DICOM viewers. The radiographs were scored for osteoarthritis and positioning. Using pooled results, the mean TPA from the digital images employing Web1000 (26.47 degrees +/- 3.90) was significantly higher then the mean TPA using film radiographs (25.41 degrees +/- 3.51), or IQ-View Pro (25.48 degrees +/- 3.89). There was not a significant difference between mean TPA using radiographs or IQ-view. Digital TPA measurement using built-in angle calipers in the clinical setting is a valid technique compared to measurements from film radiographs, and produces reproducible results. However, before changing to digital measurements, the chosen software programme should be validated against measurements using film radiographs to determine the magnitude of differences.
引用
收藏
页码:129 / 132
页数:4
相关论文
共 50 条
  • [21] Comparative study of manual and digital method in the calculation of the tibial plateau angle in dogs
    Alves, A. M.
    Capelasso, S.
    Zanatta, R.
    Oliveira, R. S. L.
    Santos, M. D.
    Silva, F. M.
    Ferrigno, C. R. A.
    Dower, N. M. B.
    Freitas, S. H.
    Yamauchi, K. C. I.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2018, 70 (01) : 117 - 121
  • [22] Radiographic Comparison of Virtual Surgical Corrective Options for Excessive Tibial Plateau Angle in the Dog
    Worden, Natalie J.
    Oxley, Bill
    Naiman, Jaron
    Karlin, William Michael
    Chen, Tiffany M.
    Hetzel, Scott J.
    Bleedorn, Jason
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 36 (05) : 225 - 235
  • [23] DIGITAL METHODS OF FREQUENCY MEASUREMENT - COMPARISON
    MARTIN, JD
    RADIO AND ELECTRONIC ENGINEER, 1972, 42 (06): : 285 - +
  • [24] Improving the Luminance Measurement from Digital Images
    Galatanu, Catalin Daniel
    2019 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL AND ENERGY SYSTEMS (SIELMEN), 2019,
  • [25] Microscopic measurement using deconvolution of digital images
    Du, Hua-Yue
    Gu, Ji-Hua
    Yang, Yong
    Qian, Yong
    Guangxue Jishu/Optical Technique, 2007, 33 (04): : 576 - 579
  • [26] Bidimensional strain measurement using digital images
    Vacher, P
    Dumoulin, S
    Morestin, F
    Mguil-Touchal, S
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1999, 213 (08) : 811 - 817
  • [27] Automatic Evaluation of Collimation Field Rotation Angle in Digital Radiographic Images
    Starcevic, Dorde S.
    Ostojic, Vladimir S.
    Petrovic, Vladimir S.
    2016 24TH TELECOMMUNICATIONS FORUM (TELFOR), 2016, : 376 - 379
  • [28] Measurement of choroidal melanoma basal diameter by wide-angle digital fundus camera: A comparison with ultrasound measurement
    Pe'er, J
    Sancho, C
    Cantu, J
    Eilam, S
    Barzel, I
    Shulman, M
    Blumenthal, EZ
    OPHTHALMOLOGICA, 2006, 220 (03) : 194 - 197
  • [29] Digital photographic measurement in hypospadias: Validation and comparison to intraoperative measurement
    Akhavan, Ardavan
    Merguerian, Paul A.
    Grady, Richard W.
    DiSandro, Michael
    Shnorhavorian, Margarett
    JOURNAL OF PEDIATRIC UROLOGY, 2014, 10 (02) : 312 - 316
  • [30] Measurement of the tibial plateau angle in cats with and without cranial cruciate ligament rupture
    Schnabl, E.
    Reese, S.
    Lorinson, K.
    Lorinson, D.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2009, 22 (02) : 83 - 86