Digital measurement of radiographic tibial plateau angle. A comparison to measurement on printed digital images

被引:17
|
作者
Lister, S. A. [1 ]
Roush, J. K. [1 ]
Renberg, W. C. [1 ]
机构
[1] Kansas State Univ, Coll Vet Med, Dept Small Anim Surg, Manhattan, KS 66506 USA
关键词
TPA; TPLO; digital measurement; canine;
D O I
10.3415/VCOT-07-05-0046
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Pre-operative digital radiographs from 50 dogs undergoing a tibial plateau leveling osteotomy were evaluated. Tibial plateau angles were measured directly on printed films and measured on digital images using two different commercial DICOM viewers. The radiographs were scored for osteoarthritis and positioning. Using pooled results, the mean TPA from the digital images employing Web1000 (26.47 degrees +/- 3.90) was significantly higher then the mean TPA using film radiographs (25.41 degrees +/- 3.51), or IQ-View Pro (25.48 degrees +/- 3.89). There was not a significant difference between mean TPA using radiographs or IQ-view. Digital TPA measurement using built-in angle calipers in the clinical setting is a valid technique compared to measurements from film radiographs, and produces reproducible results. However, before changing to digital measurements, the chosen software programme should be validated against measurements using film radiographs to determine the magnitude of differences.
引用
收藏
页码:129 / 132
页数:4
相关论文
共 50 条
  • [1] A modified technique for radiographic measurement of the tibial plateau angle in dogs
    Stehlik, L.
    Vignoli, M.
    Proks, P.
    Trnkova, S.
    Necas, A.
    VETERINARNI MEDICINA, 2017, 62 (11) : 583 - 588
  • [2] Comparison of conventional and digital measurements of tibial plateau angle in dogs
    Serwa, Dorota
    Lorinson, Karin
    Lorinson, Dragan
    Skalicky, Monika
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2009, 234 (05): : 622 - 624
  • [3] Tibial Plateau Angle Measurement in Dogs - Comparison of Three Different Methods
    Todorovic, Anastasija Z.
    Krstic, Nikola E.
    Zikic, Dragan R.
    Van Bree, Henri J. J.
    Gielen, Ingrid M. L., V
    Macanovic, Mirjana V. Lazarevic
    ACTA VETERINARIA-BEOGRAD, 2024, 74 (01): : 17 - 29
  • [4] A novel radiographic method to facilitate measurement of the tibial plateau angle in dogs - A prospective clinical study
    Headrick, J.
    Cook, I.
    Helphrey, M.
    Crouch, D.
    Fox, D.
    Schultz, L.
    Cook, C.
    Kunkel, I.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2007, 20 (01) : 24 - 28
  • [5] Radiographic measurement of the angle of the tibial translation in the beagle dog
    Fujita, Y.
    Sawa, S.
    Muto, M.
    VETERINARY RECORD, 2017, 180 (10) : 252 - +
  • [6] Tibial plateau angle: methods of measurement, valCe, applicability
    Przeworski, Adam
    Glodek, Joanna
    Adamiak, Zbigniew
    MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2017, 73 (09): : 532 - 537
  • [7] Evaluation of Intra- and Interobserver Variability and Repeatability of Tibial Plateau Angle Measurements with Digital Radiography Using a Novel Digital Radiographic Program
    Unis, Marcos D.
    Johnson, Ann L.
    Griffon, Dominique J.
    Schaeffer, David J.
    Ragetly, Guillaume R.
    Hoffer, Melissa J.
    Ragetly, Chantal A.
    VETERINARY SURGERY, 2010, 39 (02) : 187 - 194
  • [8] A METHOD OF DIGITAL LOSS ANGLE MEASUREMENT
    KRZYWAZNIA, A
    MADEJ, P
    OCIEPKA, J
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (09): : 823 - 825
  • [9] Digital radiographic measurement of the atlantodental interval in children
    Douglas, Tania S.
    Sanders, Virginia
    Machers, Sven
    Pitcher, Richard
    van As, Arjan B.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2007, 27 (01) : 23 - 26
  • [10] Comparison of anatomical tibial plateau angle versus observer measurement from lateral radiographs in dogs
    Grierson, J
    Sanders, M
    Guitan, J
    Pead, M
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2005, 18 (04) : 215 - 219