Development and validation of a liquid chromatography with tandem mass spectrometry method for the quantification of vitisin B in rat plasma and urine

被引:3
|
作者
Choi, Woong-Kee [1 ,2 ]
Yoon, Kee Dong [1 ,2 ]
Lee, Joeng Kee [1 ,2 ]
Park, Jung Bae [1 ,2 ]
Heo, Tae-Hwe [1 ,2 ]
Lee, Choongho [3 ]
Bae, Soo Kyung [1 ,2 ]
机构
[1] Catholic Univ Korea, Coll Pharm, Bucheon 420743, Gyeonggi Do, South Korea
[2] Catholic Univ Korea, Integrated Res Inst Pharmaceut Sci, Bucheon 420743, Gyeonggi Do, South Korea
[3] Dongguk Univ, Coll Pharm, Goyang, South Korea
基金
新加坡国家研究基金会;
关键词
Liquid chromatography with tandem mass spectrometry; Pharmacokinetics; Plasma; Urine; Vitisin B; RESVERATROL OLIGOMERS; BIOFILM FORMATION;
D O I
10.1002/jssc.201500071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, rapid, and sensitive liquid chromatography with tandem mass spectrometry method was developed for the determination of vitisin B and validated in rat plasma and urine using carbamazepine as an internal standard. The plasma (0.05 mL) or urine (0.2 mL) samples were extracted by liquid-liquid extraction with ethyl acetate and separated on an Eclipse Plus C-18 column (100 x 4.6 mm, 3.5 mu m) with a mobile phase consisting of acetonitrile and 0.1% formic acid water (60: 40, v/v) at a flow rate of 0.7 mL/min. Detection and quantification were performed by mass spectrometry in selected reaction-monitoring mode with positive electrospray ionization. The calibration curves were recovered over the concentration ranges of 10-5000 ng/mL (correlation coefficients, r >= 0.9833) in plasma and 5-2500 ng/mL (r >= 0.9977) in urine, respectively. All validation data, including the specificity, precision, accuracy, recovery, and stability, conformed to the acceptance requirements. No matrix effects were observed. The developed method was successfully applied to pharmacokinetic studies of vitisin B following intravenous administration of 0.5 and 1 mg/kg and intraperitoneal injection of 5, 10, and 25 mg/kg to rats. This is the first report on the pharmacokinetic properties of vitisin B. The results provide a meaningful basis to evaluate preclinical or clinical applications of vitisin B.
引用
收藏
页码:1872 / 1880
页数:9
相关论文
共 50 条
  • [21] Method development and validation for rapid quantification of hydroxychloroquine in human blood using liquid chromatography-tandem mass Spectrometry
    Wang, Ling-Zhi
    Ong, Rina Yue-Ling
    Chin, Tan-Min
    Thuya, Win-Lwin
    Wan, Seow-Ching
    Wong, Andrea Li-Ann
    Chan, Sui-Yung
    Ho, Paul C.
    Goh, Boon-Cher
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 86 - 92
  • [22] Development of a liquid chromatography-tandem mass spectrometry method for assaying cenobamate in rat plasma
    Oh, Ji-Hoon
    Jeong, Jong-Woo
    Ji, Yu-Geun
    Shin, Yu-Mi
    Lee, Kyeong-Ryoon
    Cho, Kwan Hyung
    Koo, Tae-Sung
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2018, 41 (17-18) : 992 - 997
  • [23] Development and validation of a high-performance liquid chromatography-tandem mass spectrometry assay for the quantification of Dexamphetamine in human plasma
    Herbrink, M.
    Thijssen, B.
    Hillebrand, M. J. X.
    Rosing, H.
    Schellens, J. H. M.
    Nuijen, B.
    Beijnen, J. H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 148 : 259 - 264
  • [24] Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Estimation of Rivaroxaban in Human Plasma
    Pathan, Mudassarahemadkhan
    Kshirsagar, Ajay
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (06) : 876 - 889
  • [25] Development and validation of a liquid chromatography-tandem mass spectrometry method for determination of ibuprofen in human plasma
    Puangpetch, Apichaya
    Limrungsikul, Anchalee
    Prommas, Santirhat
    Rukthong, Pattarawit
    Sukasem, Chonlaphat
    CLINICAL MASS SPECTROMETRY, 2020, 15 : 6 - 12
  • [26] Quantification of ketamine and norketamine in bovine plasma by liquid chromatography–tandem mass spectrometry
    Mathias Devreese
    Diego Rodrigo
    Stijn Schauvliege
    Frank Gasthuys
    Patrick De Backer
    Siska Croubels
    Journal of the Iranian Chemical Society, 2015, 12 : 1357 - 1362
  • [27] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in human plasma
    Wang, Haidong
    Deng, Pan
    Chen, Xiaoyan
    Guo, Lixia
    Zhong, Dafang
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) : 34 - 38
  • [28] Development and validation of a sensitive liquid chromatography/tandem mass spectrometry method for the determination of exemestane in human plasma
    Ksycinska, Hanna
    Bus-Kwasnik, Katarzyna
    Szlagowska, Anna
    Rudzki, Piotr J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (21): : 1905 - 1910
  • [29] Liquid chromatography-tandem mass spectrometry method for the quantification of deglymidodrine in human plasma
    Jia, JY
    Liu, GY
    Li, SJ
    Li, XC
    Yuan, WF
    Yu, C
    Wang, YP
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (03) : 715 - 719
  • [30] Development and validation of sensitive liquid chromatography/tandem mass spectrometry method for quantification of bendamustine in mouse brain tissue
    He, Lei
    Grecula, John C.
    Ling, Yonghua
    Enzerra, Michael D.
    Ammirati, Mario
    Kendra, Kari
    Cavaliere, Robert
    Mayr, Nina
    McGregor, John
    Olencki, Thomas
    Mrozek, Ewa
    Matharbootham, Mani
    Oluigbo, Chima
    Phelps, Mitch A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 905 : 141 - 144