Development and validation of a liquid chromatography with tandem mass spectrometry method for the quantification of vitisin B in rat plasma and urine

被引:3
|
作者
Choi, Woong-Kee [1 ,2 ]
Yoon, Kee Dong [1 ,2 ]
Lee, Joeng Kee [1 ,2 ]
Park, Jung Bae [1 ,2 ]
Heo, Tae-Hwe [1 ,2 ]
Lee, Choongho [3 ]
Bae, Soo Kyung [1 ,2 ]
机构
[1] Catholic Univ Korea, Coll Pharm, Bucheon 420743, Gyeonggi Do, South Korea
[2] Catholic Univ Korea, Integrated Res Inst Pharmaceut Sci, Bucheon 420743, Gyeonggi Do, South Korea
[3] Dongguk Univ, Coll Pharm, Goyang, South Korea
基金
新加坡国家研究基金会;
关键词
Liquid chromatography with tandem mass spectrometry; Pharmacokinetics; Plasma; Urine; Vitisin B; RESVERATROL OLIGOMERS; BIOFILM FORMATION;
D O I
10.1002/jssc.201500071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, rapid, and sensitive liquid chromatography with tandem mass spectrometry method was developed for the determination of vitisin B and validated in rat plasma and urine using carbamazepine as an internal standard. The plasma (0.05 mL) or urine (0.2 mL) samples were extracted by liquid-liquid extraction with ethyl acetate and separated on an Eclipse Plus C-18 column (100 x 4.6 mm, 3.5 mu m) with a mobile phase consisting of acetonitrile and 0.1% formic acid water (60: 40, v/v) at a flow rate of 0.7 mL/min. Detection and quantification were performed by mass spectrometry in selected reaction-monitoring mode with positive electrospray ionization. The calibration curves were recovered over the concentration ranges of 10-5000 ng/mL (correlation coefficients, r >= 0.9833) in plasma and 5-2500 ng/mL (r >= 0.9977) in urine, respectively. All validation data, including the specificity, precision, accuracy, recovery, and stability, conformed to the acceptance requirements. No matrix effects were observed. The developed method was successfully applied to pharmacokinetic studies of vitisin B following intravenous administration of 0.5 and 1 mg/kg and intraperitoneal injection of 5, 10, and 25 mg/kg to rats. This is the first report on the pharmacokinetic properties of vitisin B. The results provide a meaningful basis to evaluate preclinical or clinical applications of vitisin B.
引用
收藏
页码:1872 / 1880
页数:9
相关论文
共 50 条
  • [1] Development and validation of a liquid chromatography-tandem mass spectrometry method for quantification of decitabine in rat plasma
    Xu, Haiyan
    Iv, Shaoqiong
    Qiao, Mingxi
    Fu, Yao
    Jiang, Xue
    Jin, Yi
    Li, Chibing
    Yuan, Bo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 899 : 81 - 85
  • [2] Bioanalytical method development, validation and quantification of flupirtine maleate in rat plasma by liquid chromatography-tandem mass spectrometry
    Kandasamy, Karthikeyan
    Gowdra, Vasantharaju Surenahalli
    Nammalvar, Hariprabhu
    Govindarajan, Arul Kumaran Kottur S.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (12): : 693 - 699
  • [3] Development and validation of a liquid chromatography-tandem mass spectrometry assay for the quantification of lurbinectedin in human plasma and urine
    van Andel, L.
    Rosing, H.
    Lubomirov, R.
    Aviles, P.
    Fudio, S.
    Tibben, M. M.
    Nan-Offering, L.
    Schellens, J. H. M.
    Beijnen, J. H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 158 : 160 - 165
  • [4] Method development for quantification of quizartinib in rat plasma by liquid chromatography/tandem mass spectrometry for pharmacokinetic application
    Ezzeldin, Essam
    Iqbal, Muzaffar
    Mostafa, Gamal
    Al-Rashood, Khalid A.
    El-Nahhas, Toqa
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (03)
  • [5] Bioanalytical Method Development and Validation of Selinexor in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry
    Yaswanth, Murthaeti
    Sreekanth, M.
    Valli, Syed Sadaq
    Narayana, D. Venkata
    Sreedhar, V
    Venkataramana, Kanuma
    Pravallika, K. E.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2022, 12 (04): : 41 - 53
  • [6] Validation of a method for quantification of ketobemidone in human plasma with liquid chromatography-tandem mass spectrometry
    Lampinen, M
    Bondesson, U
    Fredriksson, E
    Hedeland, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02): : 347 - 354
  • [7] Development and validation of a liquid chromatography/tandem mass spectrometry procedure for the quantification of adefovir in human plasma
    Chen, XY
    Liu, D
    Zhu, L
    Zhong, DF
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (13) : 1893 - 1898
  • [8] Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Glycopyrrolate in Horse Plasma
    Rumpler, M. J.
    Sams, R. A.
    Colahan, P.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (09) : 656 - 664
  • [9] Development of a liquid chromatography-tandem mass spectrometry method for quantification of the egg allergen ovalbumin in rat plasma
    Ogino, Ryohei
    Yokooji, Tomoharu
    Omoto, Asahi
    Taogoshi, Takanori
    Morita, Eishin
    Matsuo, Hiroaki
    ALLERGOLOGY INTERNATIONAL, 2019, 68 (03) : 372 - 374
  • [10] Development and validation of a fast and reliable method for the quantification of glucagon by liquid chromatography and tandem mass spectrometry
    Farre-Segura, Jordi
    Fabregat-Cabello, Neus
    Calaprice, Chiara
    Nyssen, Laurent
    Peeters, Stephanie
    Le Goff, Caroline
    Cavalier, Etienne
    CLINICA CHIMICA ACTA, 2021, 512 : 156 - 165