Including robustness in multi-criteria optimization for intensity-modulated proton therapy

被引:146
|
作者
Chen, Wei [1 ]
Unkelbach, Jan
Trofimov, Alexei
Madden, Thomas
Kooy, Hanne
Bortfeld, Thomas
Craft, David
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 03期
关键词
TREATMENT UNCERTAINTIES; RANGE UNCERTAINTIES; RADIOTHERAPY; SENSITIVITY; ALGORITHM; PLAN;
D O I
10.1088/0031-9155/57/3/591
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database of plans each emphasizing different treatment planning objectives, is pre-computed to approximate the Pareto surface. An IMPT treatment plan that strikes the best balance between the different objectives can be selected by navigating on the Pareto surface. In our approach, robustness is integrated into MCO by adding robustified objectives and constraints to the MCO problem. Uncertainties (or errors) of the robust problem are modeled by pre-calculated dose-influence matrices for a nominal scenario and a number of pre-defined error scenarios (shifted patient positions, proton beam undershoot and overshoot). Objectives and constraints can be defined for the nominal scenario, thus characterizing nominal plan quality. A robustified objective represents the worst objective function value that can be realized for any of the error scenarios and thus provides a measure of plan robustness. The optimization method is based on a linear projection solver and is capable of handling large problem sizes resulting from a fine dose grid resolution, many scenarios, and a large number of proton pencil beams. A base-of-skull case is used to demonstrate the robust optimization method. It is demonstrated that the robust optimization method reduces the sensitivity of the treatment plan to setup and range errors to a degree that is not achieved by a safety margin approach. A chordoma case is analyzed in more detail to demonstrate the involved trade-offs between target underdose and brainstem sparing as well as robustness and nominal plan quality. The latter illustrates the advantage of MCO in the context of robust planning. For all cases examined, the robust optimization for each Pareto optimal plan takes less than 5 min on a standard computer, making a computationally friendly interface possible to the planner. In conclusion, the uncertainty pertinent to the IMPT procedure can be reduced during treatment planning by optimizing plans that emphasize different treatment objectives, including robustness, and then interactively seeking for a most-preferred one from the solution Pareto surface.
引用
收藏
页码:591 / 608
页数:18
相关论文
共 50 条
  • [1] The influence of the optimization starting conditions on the robustness of intensity-modulated proton therapy plans
    Albertini, F.
    Hug, E. B.
    Lomax, A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10): : 2863 - 2878
  • [2] Weekly robustness evaluation of intensity-modulated proton therapy for oesophageal cancer
    Anakotta, R. Melissa
    van der Laan, Hans P.
    Visser, Sabine
    Ribeiro, Cassia O.
    Dieters, Margriet
    Langendijk, Johannes A.
    Both, Stefan
    Korevaar, Erik W.
    Sijtsema, Nanna M.
    Knopf, Antje
    Muijs, Christina T.
    RADIOTHERAPY AND ONCOLOGY, 2020, 151 : 66 - 72
  • [3] Proton energy optimization and reduction for intensity-modulated proton therapy
    Cao, Wenhua
    Lim, Gino
    Liao, Li
    Li, Yupeng
    Jiang, Shengpeng
    Li, Xiaoqiang
    Li, Heng
    Suzuki, Kazumichi
    Zhu, X. Ronald
    Gomez, Daniel
    Zhang, Xiaodong
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21): : 6341 - 6354
  • [4] Pseudo-automatic beam orientations in multi-criteria intensity-modulated radiation therapy
    Azizi-Sultan, Ahmad-Saher
    JOURNAL OF COMBINATORIAL OPTIMIZATION, 2016, 31 (04) : 1746 - 1759
  • [5] Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques
    Liu, Wei
    Li, Yupeng
    Li, Xiaoqiang
    Cao, Wenhua
    Zhang, Xiaodong
    MEDICAL PHYSICS, 2012, 39 (06) : 3089 - 3101
  • [6] Robust beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    Neph, Ryan
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    MEDICAL PHYSICS, 2019, 46 (08) : 3356 - 3370
  • [7] Robust optimization for intensity-modulated proton therapy with soft spot sensitivity regularization
    Gu, Wenbo
    Ruan, Dan
    O'Connor, Daniel
    Zou, Wei
    Dong, Lei
    Tsai, Min-Yu
    Jia, Xun
    Sheng, Ke
    MEDICAL PHYSICS, 2019, 46 (03) : 1408 - 1425
  • [8] Selective robust optimization: A new intensity-modulated proton therapy optimization strategy
    Li, Yupeng
    Niemela, Perttu
    Liao, Li
    Jiang, Shengpeng
    Li, Heng
    Poenisch, Falk
    Zhu, X. Ronald
    Siljamaki, Sami
    Vanderstraeten, Reynald
    Sahoo, Narayan
    Gillin, Michael
    Zhang, Xiaodong
    MEDICAL PHYSICS, 2015, 42 (08) : 4840 - 4847
  • [9] Effectiveness of robust optimization in intensity-modulated proton therapy planning for head and neck cancers
    Liu, Wei
    Frank, Steven J.
    Li, Xiaoqiang
    Li, Yupeng
    Park, Peter C.
    Dong, Lei
    Zhu, X. Ronald
    Mohan, Radhe
    MEDICAL PHYSICS, 2013, 40 (05)
  • [10] Energy layer optimization strategies for intensity-modulated proton therapy of lung cancer patients
    Jensen, M. Fuglsang
    Hoffmann, L.
    Petersen, J. B. B.
    Moller, D. S.
    Alber, M.
    MEDICAL PHYSICS, 2018, 45 (10) : 4355 - 4363