Relationship between bacterial regrowth and some physical and chemical parameters within Sydney's drinking water distribution system

被引:48
作者
Power, KN
Nagy, LA
机构
[1] Aquatech, Bruce, ACT 2617, Australia
[2] Univ New S Wales, Sch Microbiol & Immunol, Sydney, NSW 2052, Australia
关键词
regrowth; drinking water; physical-chemical parameters; Aeromonas hydrophila; Klebsiella oxytoca; coliforms;
D O I
10.1016/S0043-1354(98)00251-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A sampling program was set up within the Water Board (Sydney) drinking water distribution system to determine the presence and extent of bacterial regrowth. System, physical, chemical and microbiological parameters, including the identification of bacteria isolated, were measured over a 14 month period and correlation analysis was carried out. Results showed that regrowth was present within the system and that certain parameters, such as turbidity and distance from the initial treatment point, correlated with the presence of high bacterial numbers. identification of bacteria isolated on m-Endo broth indicated Klebsiella oxytoca as the principal coliform involved. High numbers of Aeromonas hydrophila were also isolated. (C) 1998 Elsevier Science Ltd. All lights reserved.
引用
收藏
页码:741 / 750
页数:10
相关论文
共 37 条
[1]  
American Public Health Association, 1985, STAND METH EX WAT WA
[2]   ISOLATION OF AEROMONAS SPP FROM AN UNCHLORINATED DOMESTIC WATER-SUPPLY [J].
BURKE, V ;
ROBINSON, J ;
GRACEY, M ;
PETERSON, D ;
MEYER, N ;
HALEY, V .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 48 (02) :367-370
[3]   BIOTYPING AND VIRULENCE FACTORS IN CLINICAL AND ENVIRONMENTAL ISOLATES OF AEROMONAS SPECIES [J].
BURKE, V ;
ROBINSON, J ;
COOPER, M ;
BEAMAN, J ;
PARTRIDGE, K ;
PETERSON, D ;
GRACEY, M .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 47 (05) :1146-1149
[4]   BACTERIAL INTERFERENCE WITH COLIFORM COLONY SHEEN PRODUCTION ON MEMBRANE FILTERS [J].
BURLINGAME, GA ;
MCELHANEY, J ;
BENNETT, M ;
PIPES, WO .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 47 (01) :56-60
[5]   GROWTH-KINETICS OF COLIFORM BACTERIA UNDER CONDITIONS RELEVANT TO DRINKING-WATER DISTRIBUTION-SYSTEMS [J].
CAMPER, AK ;
MCFETERS, GA ;
CHARACKLIS, WG ;
JONES, WL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (08) :2233-2239
[6]   BACTERIA ASSOCIATED WITH ANTIGRANULOCYTES ACTIVATED CARBON PARTICLES IN DRINKING-WATER [J].
CAMPER, AK ;
LECHEVALLIER, MW ;
BROADAWAY, SC ;
MCFETERS, GA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1986, 52 (03) :434-438
[7]   CHARACTERIZATION OF INDICATOR BACTERIA IN MUNICIPAL RAW WATER, DRINKING-WATER, AND NEW MAIN WATER SAMPLES [J].
CLARK, JA ;
BURGER, CA ;
SABATINOS, LE .
CANADIAN JOURNAL OF MICROBIOLOGY, 1982, 28 (09) :1002-1013
[8]  
EDGE JC, 1987, WAT ENV MANAG, V1, P104
[9]  
GELDREICH EE, 1987, J AM WATER WORKS ASS, V79, P74
[10]  
GELDREICH EE, 1986, NEW ENGL SECT AWWA C