Limited-sample NMR using solenoidal microcoils perfluouocarbon plugs, and capillary spinning

被引:25
作者
Behnia, B
Webb, AG
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
关键词
D O I
10.1021/ac9808371
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study demonstrates three improvements to mass-limited NMR using solenoidal microcoils as detectors: (1) sample confinement using liquid perfluorocarbon plugs to increase the observe factor, (2) design and incorporation of a capillary spinner to improve spectral line widths, and (3) facile sample changing via the use of a capillary insert. The probe is constructed to spin a fused silica capillary of 530 pm i.d., 700 mu m o.d. inside a solenoidal coil wound around a 0.8 mm i.d., 1 mm o.d. glass capillary. The smaller capillary contains the sample, and capillaries with different samples can be exchanged easily, In high-resolution limited sample microcoil NMR studies published thus far, the length of the sample plug has been 7-10 times the length of the solenoid to avoid line broadening from volume magnetic susceptibility (chi(v)) mismatches at both ends of the sample. This arrangement is not efficient since it places most of the sample volume outside of the coil observe volume, It is shown here that the observe factor cannot exceed 23% if the sample plug is bracketed by air, without substantial line broadening occurring. However, if the sample is bracketed by two liquid perfluorocarbon plugs, the observe factor can be increased to 70% while maintaining high spectral resolution. This is equivalent to improving the limit of detection by a factor of 3, or reducing the total data acquisition time for a given signal-to-noise by a factor of 9, It is also shown that, for the 440-nL sample plug used in this study (bracketed by the perflurocarbon plugs), sample spinning can improve the spectral resolution from 1.5 (nonspinning) to 0.6 Hz(spinning). This corresponds to a further improvement in the limit of detection of 2.5, or just over a factor of 6 decrease in data acquisition time.
引用
收藏
页码:5326 / 5331
页数:6
相关论文
共 19 条
  • [1] BEHNIA B, 1998, THESIS U ILLINOIS UR
  • [2] NUMERICAL-ANALYSIS OF THE MAGNETIC-FIELD FOR ARBITRARY MAGNETIC-SUSCEPTIBILITY DISTRIBUTIONS IN 2D
    BHAGWANDIEN, R
    VANEE, R
    BEERSMA, R
    BAKKER, CJG
    MOERLAND, MA
    LAGENDIJK, JJW
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (02) : 299 - 313
  • [3] SUSCEPTIBILITY-LIMITED RESOLUTION IN NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY
    CALLAGHAN, PT
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (02): : 304 - 318
  • [4] Doty FD, 1998, CONCEPT MAGNETIC RES, V10, P133, DOI 10.1002/(SICI)1099-0534(1998)10:3<133::AID-CMR1>3.0.CO
  • [5] 2-Y
  • [6] FREEMAN R, 1988, HDB NUCLEAR MAGNETIC, P194
  • [7] GRIFFITHS DJ, 1989, INTRO ELECTRODYNAMIC, P245
  • [8] MAGNETIC-SUSCEPTIBILITY OF SOME MATERIALS USED FOR APPARATUS CONSTRUCTION (AT 295-K)
    KEYSER, PT
    JEFFERTS, SR
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (08) : 2711 - 2714
  • [9] Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
  • [10] The nanoliter niche - NMR detection for trace analysis and capillary separations
    Olson, DL
    Lacey, ME
    Sweedler, JV
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (07) : 257A - 264A